This document could not be shown here. Open the PDF.
Text of this document5 pages · 457 words
Page 1
MDM-SPLIT T1160 MOVING DOOR MECHANISM Open Position Closed Position Representative Moving panels TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
MDM-SPLIT T1160 MOVING DOOR MECHANISM PANELS CLOSED Recommended minimum space at end of mechanism to allow access to belt tensioner Motor located at the Left of the mechanism. Recommended to 7 7/8" allow access from below for 200 servicing. Areas requires access for switch adjustment from below 23 1/4" 23 1/4" 590 590 1/8" 3 46 9/16" 1183 102 3/8" PANELS OPEN 2600 23 1/4" 23 1/4" 590 590 45 11/16" 1160 MAX. TRAVEL TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
MDM-SPLIT T1160 MOVING DOOR MECHANISM GENERAL DIMENSIONS Cable loom to control Board from motor end of mechanism 3/8" 3 7/8" DETAIL B 10 99 SCALE 1 : 4 MDM is fixed from Maximum underneath through Length of Fixing Head mounting holes in A the column C L SYM Rear view of Mechanism 3 15/16" 100 4 15/16" 125 B 5 1/8" 5 1/8" 130 130 A 2 3/8" 23 1/4" 23 1/4" 60 590 590 45 11/16" 1160 92 1/8" 2340 3/4" 19 SECTION A-A 102 3/8" SCALE 1 : 3 2600 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
MDM-SPLIT T1160 MOVING DOOR MECHANISM SWITCH ADJUSTMENT The limit switches can be adjusted using an allen key. Undo the bolts and slide DETAIL D switch to desired position. SCALE 1 : 2 D TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
MDM-SPLIT T1160 MOVING DOOR MECHANISM
308 12 1/8"
CABLE LOOM RS232 PORT IR OUTPUT LENGTH APPROX INDICATOR LED 118 1/8" CONTACT 3000 CLOSURE PORT IR LEAD INPUT 3.5mm [0.14"] JACK EMERGENCY STOP
CONNECTOR 20 max 0.79 max
5/16"
52 8 CORE CABLE 2 1/16"
MOTOR 5 10mm [0.4"] dia. 3/16" 5 7/8" 3 CORE CABLE MAINS INPUT
EU SPEC: 0.5mm² 150 SWITCH LIMITS US SPEC: 20AWG 6mm [0.25"] dia. EU SPEC: 0.5mm² NOTES US SPEC: 20AWG • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 5 FUTUREAUTOMATION