MDM SPLIT MOVING DOOR MECHANISM Open Position Closed Position Representative Moving panels TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
MDM SPLIT MOVING DOOR MECHANISM Recommended minimum space at end of mechanism to Area requires access allow access to belt tensioner for the motor PANELS CLOSED Recommended minimum space at end of mechanism to allow access to belt tensioner 7.87 7.87 200 200 Areas requires access for switch Areas requires access for switch adjustment from below adjustment from below 31.00 31.00 787.5 787.5 62.01 1575 0.98 PANELS OPEN 25 66.93 66.93 1700 1700 13.78 350 Hanger Seperation 29.59 29.59 751.5 751.5 59.17 1503 MAX. TRAVEL C L TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
MDM SPLIT MOVING DOOR MECHANISM GENERAL DIMENSIONS Cable loom to control Boards DETAIL C SCALE 1 : 6 Hanger Adjustment 0.39 Loosen the nuts and raise or lower 3.90 10 3.29 ±0.12 to desired position 99 83.5 ±3 Maximum MDM is fixed from Length of underneath through 7.66 7.66 mounting holes in the Fixing Head 195 195 8.01 column 203.5 Motors located at the middle of the mechanism. Recommended to allow access from below for servicing. DETAIL B SCALE 1 : 4 3.94 100 66.93 66.93 A 7.17 1700 1700 182 2.12 54 C A B 0.98 25 C L SYM 1.77 45 31.00 29.59 29.59 31.00 787.5 751.5 751.5 787.5 121.18 3078 SECTION A-A SCALE 1 : 3 134.84 3425 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
MDM SPLIT MOVING DOOR MECHANISM SWITCH ADJUSTMENT The limit switches can be adjusted using a 3mm allen key. Undo the bolts and slide switch to desired position. DETAIL D SCALE 1 : 2 D TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
MDM SPLIT CONTROL BOX FOR MOVING DOOR MECHANISM The two separate sides each come with a control box as shown
12.11307.5
CABLE LOOM RS232 PORT IR OUTPUT LENGTH APPROX INDICATOR LED 118 CONTACT 3000 CLOSURE PORT IR LEAD INPUT 3.5mm [0.14"] JACK EMERGENCY STOP
CONNECTOR 20 max 0.79 max
0.28
7 8.2 0.32
2.0552.1 8 CORE CABLE
MOTOR 5.2 10mm [0.4"] dia. 0.20 5.89 3 CORE CABLE
MAINS INPUT EU SPEC: 0.5mm² 149.5 SWITCH LIMITS US SPEC: 20AWG 6mm [0.25"] dia. EU SPEC: 0.5mm² NOTES US SPEC: 20AWG • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 5 FUTUREAUTOMATION