Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Colourful headboard with blue and orange cushions

Lutron Grafik Eye 3000

Grafik Eye 3000 is a range of configurable multi-circuit lighting control units, where lighting scenes can be pre-programmed and then recalled at the touch of a button.

32 products

About GRAFIK Eye 3000

GRAFIK Eye 3000 is Lutron’s preset lighting control unit with dimmers built in, for homes and smaller commercial spaces. Each unit controls two, three, four or six zones and recalls 16 scenes: four and Off from its own buttons, and twelve more from wallstations or control interfaces. The GRAFIK Integrale (GXI) versions add LED, 0–10 V and DALI. Up to eight units link with wallstations into one system. Our units are refurbished or new box opened. Stock changes as units are sourced: if the model you need is not listed, contact us.

What you need for a system

This is an outline only. A system may need parts not listed here, and the exact parts and quantities depend on the project. The parts listed on our website are available to order. For anything else, please get in touch.

PartCodeNotes
Control unitGRX-3102-CE, GRX-3103-CE, GRX-3104-CE, GRX-3106-CE, GRX-3504-CE, GRX-3506-CE2, 3, 4 or 6 zones; the 35xx adds PC set-up
Control unit, GRAFIK IntegraleGXI-3104-CE, GXI-3504-CE4 zones; LED, 0–10 V and DALI
WallstationsArchitectural, slim button, large button, European style, ArchitraveWork with GRAFIK Eye 3000 and 4000
Replacement faceplateGRX-4GRCFour-gang, for every 230 V GRX unit
Back boxRecessed in-wall, surfaceRefurbished. Units fit Lutron’s 241-400 four-gang box
Control link cableGRX-CBL-346S-500, GRX-PCBL346S-500Standard and plenum
PC interfaceGRX-PRGFor PC set-up of 35xx units

Technical details

Choosing a unit

UnitsZonesLoadsSet-up
GRX-31xx2, 3, 4 or 6Incandescent directly; electronic low-voltage and fluorescent through Lutron interfacesFront panel
GRX-35xx2, 3, 4 or 6As the GRX-31xxFront panel, or a PC; levels in 1% steps
GXI-31044LED, incandescent, electronic and magnetic low-voltage, fluorescent, neon. Each zone leading or trailing edge, 0–10 V, DALI (broadcast) or switchedFront panel
GXI-35044As the GXI-3104Front panel, or a PC; levels in 1% steps

The 3500 shares the 3100’s hardware, ratings and back box, and works in existing 3100 systems. Our guide Comparing Lutron GRAFIK Eye 310x to 350x compares the two in more detail.

Loads and ratings

Each zone takes up to 800 W, and each 3-, 4- or 6-zone GRX unit and each GXI up to 2,300 W in all. A connected zone needs at least 40 W, unused zones can be left unconnected, and a zone controls one load type. A Lutron power booster (NGRX-PB) adds capacity to a zone.

The GXI drives up to 20 LED drivers or ballasts per zone on its 0–10 V or DALI output. Set to Auto Phase, a GXI zone starts in trailing edge and changes to leading edge for a magnetic load.

Protect each unit with an MCB of 10 A at most, curve C. Wired phase to phase, the unit has no air gap when off, so switch off the MCB before working on it. About 2% of the load is given off as heat, so a warm faceplate is normal.

Control link and wallstations

Units, wallstations and control interfaces connect on a four-wire control link, daisy-chained and kept apart from mains wiring. Pin 1 is common, pin 2 is 12 V DC, and pins 3 and 4 are the two data lines (MUX). Lutron’s cable for it is GRX-CBL-346S, or GRX-PCBL-346S where plenum cable is needed.

A system takes up to eight units (addresses A1 to A8) and 16 wallstations or control interfaces: up to 48 zones with GRX units or 32 with GXI, and 128 scenes. Hand-held remotes and NTGRX-1S entrance controls don’t count towards the 16. Each unit needs its own address, with two-way talk and listen set up between linked units. Wallstations take a DIP-switch address from 1 to 16; 16 is kept for the GRX-PRG PC interface.

Each unit powers up to three wallstations. Beyond that, add a regulated Class 2 / PELV 12 V DC supply, at least 50 mA per wallstation and up to 16 wallstations per supply. Lutron’s own GRX-12VDC is a 120 V transformer. The same wallstations work with GRAFIK Eye 4000, wired differently for power.

Set-up

Hold Scene 1 and Off for three seconds to enter set-up: load type (LS), low-end trim (LE), scenes (Sc), address (A-) and save options (Sd). The GXI adds high-end trim (HE).

GRX zones leave the factory set to incandescent. GXI zones leave it set to non-dim, and won’t dim until a load type is set. Each scene has its own fade time, from 0 to 59 seconds or 1 to 60 minutes.

The 3500 shows exact percentages and sets levels in 1% steps at the unit. It can also be set up from a PC, through a GRX-PRG interface on the control link, with Lutron’s LIAISON software.

Mounting and faceplates

Every 230 V GRX unit, the 2- and 3-zone models included, and the GXI mount in one Lutron 241-400 four-gang back box, and every GRX unit takes the four-gang GRX-4GRC faceplate. The faceplate is 227 × 116 mm.

Faceplates come opaque (A) or translucent (T). Gloss finishes are opaque only, and metal and anodised finishes translucent only. An opaque faceplate hides the zone LEDs.

We supply units without a faceplate unless you ask for one when ordering.

Reading the product code

GRX–3504–CE

The GRX-3504-CE is a GRAFIK Eye 3000 Series control unit with 4 zones of built-in dimming, configured from its front panel or from a PC using configuration software, for 230 V (CE).

1 Range
  • GRXGRAFIK Eye
  • GXIGRAFIK Integrale

GRX needs a Lutron interface for electronic low-voltage and fluorescent loads. GXI adds trailing-edge dimming and 0–10 V and DALI outputs, so it runs LED drivers without one.

2 Series
  • 33000 Series, dimmers built in
  • 44000 Series, separate dimming panels

See our GRAFIK Eye 4000 range.

3 Set-up
  • 1configured from the front panel
  • 5front panel or PC configuration software
4 Zones
  • 022 zones
  • 033 zones
  • 044 zones
  • 066 zones
  • 088 zones
  • 1616 zones
  • 2424 zones

3000 Series: 2 to 6 zones (GXI 4 only). 4000 Series: 2 to 24.

5 Voltage
  • CE230 V (CE)
  • AU220–240 V (non-CE)
  • JA100 V

No code for 120 V.

Frequently asked questions

What is the difference between the GRX-3104 and the GRX-3504?

Both are four-zone units with the same ratings and back box. The 3504 can also be set up from a PC, through a GRX-PRG interface, and sets levels in 1% steps; it works in existing 3100 systems.

What does a GXI unit do that a GRX doesn't?

The GRAFIK Integrale (GXI) runs LED and electronic loads without an interface: each zone can be set to leading or trailing edge, 0–10 V, DALI (broadcast) or switched. A GRX unit needs a Lutron interface for electronic low-voltage and fluorescent loads.

Do GRAFIK Eye 3000 units dim LED lighting?

Although the GRX range was not originally intended to dim LEDs, GRX units can dim good quality leading edge LEDs, and GXI units can dim good quality leading and trailing edge LEDs. Please contact us to discuss LED specification.

How much load can a 230 V GRAFIK Eye 3000 unit take?

Up to 800 W per zone, and 2,300 W per unit for the 3-, 4- and 6-zone GRX units and the GXI. Each connected zone needs at least 40 W, and a Lutron power booster adds capacity to a zone.

Which back box and faceplate does a 230 V unit need?

Every 230 V GRX unit, including the 2- and 3-zone models, and the GXI fit one Lutron 241-400 four-gang back box. Every GRX unit takes the four-gang GRX-4GRC faceplate, opaque (A) or translucent (T).

How many units and wallstations can be linked?

Up to eight units and 16 wallstations or control interfaces: up to 48 zones with GRX units or 32 with GXI. Hand-held remotes and NTGRX-1S entrance controls don't count towards the 16.

How many wallstations can one unit power?

Three. More than that needs a regulated Class 2 / PELV 12 V DC supply, rated at least 50 mA per wallstation, for up to 16 wallstations.

Why won't a new GXI unit dim?

Its zones leave the factory set to non-dim. Set each zone's load type in set-up (hold Scene 1 and Off for three seconds) and it will dim.

How do I order GRAFIK Eye 3000 parts?

Units are refurbished or new box opened, and come without a faceplate unless you ask for one when ordering. The parts listed on our website are available to order. If you need assistance with a GRAFIK Eye 3000 system, please get in touch.

Planning or servicing a Grafik Eye 3000 system?

Contact us to discuss your project.

Contact us to discuss