Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Colourful headboard with blue and orange cushions

Lutron Grafik Eye 4000

Grafik Eye 4000 is a range of configurable multi-circuit lighting control units, which communicate with separate dimming and switching panels.

19 products

About GRAFIK Eye 4000

GRAFIK Eye 4000 is Lutron’s preset lighting control unit for architectural lighting, used with separate Lutron dimming and switching panels rather than dimmers built in. Each unit controls 2, 3, 4, 6, 8, 16 or 24 zones and 16 scenes, four and Off from its own buttons, and a system takes up to 64 zones and 32 panels. The 4100 models are set up from the front panel, and the 4500 models from the front panel or a PC. We supply GRAFIK Eye 4000 control units as part of a Lutron system, with the wallstations that work with them.

What you need for a system

This is an outline only. A system may need parts not listed here, and the exact parts and quantities depend on the project. GRAFIK Eye 4000 systems are priced on request.

PartCodeNotes
Control unit, front-panel set-upGRX-4102-CE, GRX-4103-CE, GRX-4104-CE, GRX-4106-CE, GRX-4108-CE, GRX-4116-CE, GRX-4124-CE2, 3, 4, 6, 8, 16 or 24 zones
Control unit, PC set-upGRX-4502-CE, GRX-4503-CE, GRX-4504-CE, GRX-4506-CE, GRX-4508-CE, GRX-4516-CE, GRX-4524-CEAlso set up from a PC; levels in 1% steps
Dimming and switching panelsLutron GP and LP, XPDimming panels, switching panels
WallstationsArchitectural, slim button, large button, European style, ArchitraveThe same as GRAFIK Eye 3000
Replacement faceplateGRX-4GRCFour-gang, for 4- to 24-zone units
Control link cableGRX-CBL-46L-500, GRX-PCBL-46L-500Standard and plenum
PC interface and timeclockGRX-PRG, GRX-ATCPC set-up of 45xx units; astronomic timeclock

Technical details

How a system fits together

Up to
Control unit addresses8. A 16-zone unit takes two and a 24-zone unit three: address those first
Zones64 in a system; 2 to 24 per unit
Panels32
Wallstations, control interfaces and window treatment stations16
Scenes16 per unit, 128 in a system

The panels do the dimming and switching. Their circuit selectors set each circuit’s load type and assign circuits to zones; at the control unit, each zone is set only as dimmed or non-dim. 16- and 24-zone units show eight zones at a time, with a Zone Select button.

Panels have a normal and emergency switch, and emergency circuits go to full on when normal power fails. Options include two control links in each panel, handing control to a theatrical stageboard, and DMX512, RS232, Ethernet, contact closure and infrared interfaces.

Panels at 230 V

Lutron lists 230 V CE versions of its GP and LP dimming panels and its XP switching panels. GP panels are rated 10 A per circuit at 230 V, LP panels 13 A per four-zone module, with 16 A breakers, and XP panels 16 A continuous per circuit.

The panels dim incandescent, magnetic and electronic low-voltage, fluorescent, neon and Tu-Wire loads, switch HID lighting, and control window treatments. LED is dimmed through Hi-lume A or forward-phase drivers, and 0–10 V, DALI (broadcast) and PWM drivers through a ten-volt module or interface.

Control link and wallstations

The control link runs at 24 V DC, powered from the panels. The control unit’s terminals are 1 common, 2 24 V DC, 3 and 4 the two data lines (MUX), and D the drain. Lutron’s cable is GRX-CBL-46L: two 12 AWG power conductors and a twisted, shielded data pair. Keep the link out of mains trunking; earthing the control unit is recommended.

The GRAFIK Eye wallstations work with both GRAFIK Eye 3000 and 4000 units, wired differently for power: on a 4000 system they take the two 12 AWG power wires at 24 V DC. The 4- to 24-zone units fit a Lutron 241-400 four-gang back box and take the four-gang GRX-4GRC faceplate.

GRAFIK Eye 4000 or 3000

GRAFIK Eye 3000GRAFIK Eye 4000
DimmersIn the unitIn separate panels
Zones per unit2 to 62 to 24
Zones per system4864
Control link power12 V DC, from the units24 V DC, from the panels
Control link cableGRX-CBL-346SGRX-CBL-46L

The 4500 models share the 4100’s hardware and work in existing systems, as the 3500 does with the 3100.

Reading the product code

GRX–4104–CE

The GRX-4104-CE is a GRAFIK Eye 4000 Series control unit with 4 zones on separate dimming panels, configured from its front panel, for 230 V (CE).

1 Range
  • GRXGRAFIK Eye
  • GXIGRAFIK Integrale

GRX needs a Lutron interface for electronic low-voltage and fluorescent loads. GXI adds trailing-edge dimming and 0–10 V and DALI outputs, so it runs LED drivers without one.

2 Series
  • 33000 Series, dimmers built in
  • 44000 Series, separate dimming panels
3 Set-up
  • 1configured from the front panel
  • 5front panel or PC configuration software
4 Zones
  • 022 zones
  • 033 zones
  • 044 zones
  • 066 zones
  • 088 zones
  • 1616 zones
  • 2424 zones

3000 Series: 2 to 6 zones (GXI 4 only). 4000 Series: 2 to 24.

5 Voltage
  • CE230 V (CE)
  • AU220–240 V (non-CE)
  • JA100 V

No code for 120 V.

Frequently asked questions

What is GRAFIK Eye 4000, and how is it different from GRAFIK Eye 3000?

A GRAFIK Eye 4000 control unit has no dimmers of its own: it runs separate Lutron GP and LP dimming panels and XP switching panels. It controls 2 to 24 zones per unit and up to 64 in a system, where a GRAFIK Eye 3000 unit has two to six zones of built-in dimming.

What is the difference between the GRX-4104 and the GRX-4504?

Both are four-zone control units. The 4504 can also be set up from a PC, through a GRX-PRG interface, and sets levels in 1% steps.

How big can a GRAFIK Eye 4000 system be?

Eight control unit addresses and 64 zones; a 16-zone unit takes two addresses and a 24-zone unit three. Up to 32 panels, and 16 wallstations or control interfaces.

Which panels does a 230 V GRAFIK Eye 4000 system use?

Lutron's 230 V CE versions of the GP and LP dimming panels and the XP switching panels. GP panels are rated 10 A per circuit, LP panels 13 A per module and XP panels 16 A per circuit.

Can GRAFIK Eye 4000 dim LED lighting?

Yes, through its panels: Hi-lume A and forward-phase LED drivers directly, and 0–10 V, DALI (broadcast) and PWM drivers through a ten-volt module or interface.

Which wallstations work with GRAFIK Eye 4000?

The GRAFIK Eye wallstations: Architectural, slim button, large button, European style and Architrave, and the NTGRX-1S entrance control. On a 4000 system they take two 12 AWG power wires at 24 V DC.

Which back box and faceplate does a GRAFIK Eye 4000 unit need?

The 4- to 24-zone units fit a Lutron 241-400 four-gang back box and take the four-gang GRX-4GRC faceplate.

How do I order GRAFIK Eye 4000 parts?

GRAFIK Eye 4000 control units are supplied as part of a Lutron system, and GRAFIK Eye 4000 systems are priced on request. Contact us to discuss your project.

Planning or servicing a Grafik Eye 4000 system?

Contact us to discuss your project.

Contact us to discuss