Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Lutron HomeWorks In-Line Dimmer, Switch and Fan Control – installation instructions (043613 Rev. A)

Page 1 of 1100%
Text of this document1 page · 1,326 words

Page 1

Installing the in-line load control IMPORTANT 1. CAUTION: Use only with permanently installed fixtures. lutron.com Turn OFF power at circuit breaker or remove fuse Install endcap and screw To avoid overheating and possible damage to other equipment, 1 4 do not use to control receptacles. lu tron.co lutron.com P/N 043613 Rev A English WARNING: SHOCK HAZARD. m 2. Install in accordance with all national and local electrical codes. May result in serious injury or death. Always isolate the mains power supply or 3. For indoor use only between 0 °C and 40 °C (32 °F and 104 °F); remove fuse before servicing or installing. 0% – 90% humidity, non-condensing. In-line Dimmer 4. In-line dimmers are not rated for MLV loads and are only HQRK-R25NE-240 compatible with reverse-phase loads. Magnetic low-voltage Connect wires (MLV) loads require a forward-phase device or switch for proper HQRM-R25NE-240 2 operation. HQRN-R25NE-240 5. The in-line fan control is only compatible with AC fans. Not for use HQRQ-R25NE-240 Breaker L = Live 5 Install load control with DC/BLDC motor fans, fans with a remote control, Wi-Fi only 220 – 240 V~ 50 / 60 Hz = Earth 5 mm fans or exhaust fans (bathroom or kitchen exhaust fans). Do not L N = Neutral The load control must be installed in an adequately ventilated area as shown below connect to any other motor-operated appliance or to any lighting / / without heat generating equipment, or obstructions. During normal operation, the in-line LED 1 A 250 W = Dimmed Live lutron.com load type, including lighting loads on a fan. 1 A 150 W Incandescent / N = Switched Live switch will make an audible click. DEL LED* Halogen Hereby, Lutron Electronics Co., Inc. declares that the radio equipment type HQRK-R25NE-240, N = Fan Live HQRK-RNFSQ-240 and HQRK-R6ANS-240 are in compliance with Directive 2014/53/EU ELV lutron.com lutron.com Notes: The full text of the EU declaration of conformity is available at the following internet address: * LED Load Capacity: LED current ratings must be below 1 A. If no current • For optimal RF performance, no metal or other electrically conductive material should be Lutron.com/cedoc rating is available, wattage must be below 150 W. Products must be installed in accordance with the latest present within 120 mm around the top and sides of the load control. Troubleshooting Load building and IEE wiring regulations. • The load control is not suitable for installation in places where it is fully enclosed in metal In-line Switch (e.g., metal enclosures, electrical cabinets). Symptoms Probable cause • Light bulb(s) burned out. HQRK-R6ANS-240 • Breaker is OFF or tripped. Install strain relief and tighten screws • Light not properly installed. HQRM-R6ANS-240 3 lutron.com Load does not • Wiring error. I n HQRN-R6ANS-240 n s turn on. io ula • Fan pull chain or integrated power switch t t ula ion is off. HQRQ-R6ANS-240 Correct Incorrect s n Strain relief I • Error has occurred. See Error Codes E M 120 mm 220 – 240 V~ 50 / 60 Hz section for more information. LED LV LV 6 AX Ground wires require ø 50 mm 105 mm • System devices are too far apart. DEL All lighting • The load control is already at the light additional length during 26 mm level / fan speed. 2 A 0.5 HP installation. Load does not respond • The load control is not associated with a M to controls. system or Pico wireless control. Motor • The controls are outside the 9 m (30 ft) operating range. • Error has occurred. See Error Codes section for more information. In-line Fan Control Note: All outside wire diameters must be the same and • Load turns off while HQRK-RNFSQ-240 must be between 5.2 – 8.5 mm. 6 Turn ON power at circuit breaker or install fuse being dimmed. A B • Load turns on at high • Verify LED bulbs are marked dimmable. HQRN-RNFSQ-240 light level but does not • Low-end trim may need to be adjusted for Two sizes of strain reliefs included. A provides the best CAUTION: RISK OF BODILY HARM. Fan will turn on turn on at a low light best LED bulb performance. Trim can be 220 – 240 V~ 50 / 60 Hz and start spinning for two (2) minutes once power is level. adjusted in the HomeWorks software. strain relief for most wire diameters. For some large wire applied. Stay clear of the ceiling fan before applying • Load flickers or flashes Single AC Ceiling Fan applications, B will be needed. power. Disconnect power before servicing. See the when dimmed to a low 100 W light level. Troubleshooting section if the fan does not turn on. This only applies to in-line fan controls. • Ceiling fan stalls at Fan speed settings may need to be adjusted low level. for best ceiling fan performance. Fan speed • Fan speed settings are settings can be adjusted in the Lutron Pairing a Pico Wireless Control to an Operation too slow or too fast. Designer software. Fan only works at Lutron in-line fan controls are designed to In-Line Load Control Without a System In-Line Dimmer and Switch - Button toggles the load on and off. high level. work with AC fans only. Confirm fan type with Complies with In-Line Fan Control - Button does not control the fan. The button fan manufacturer. ImDA standards CAUTION: RISK OF BODILY HARM. The ceiling fan will start spinning when a Pico wireless is used for pairing and factory reset only. DA 103083 control button is pressed after pairing. Remain clear of the ceiling fan before pressing the Pico lutron.com Return to Factory Settings wireless control buttons. This only applies to in-line fan controls. For advanced features, tips for using LEDs, the 1. Quickly triple tap the button on the load control, holding on the complete HomeWorks product line, and more, please 1. Press and hold the button on the in-line load Figure 1 Figure 2 Green - Blinks when load is toggled. Flashes during association third tap. visit www.lutron.com/homeworks control for six (6) seconds. The LED will begin 2. Once the load starts to flash, release the button and immediately flashing. The device will stay in pairing mode for Blue - Advanced programming mode (APM) ten (10) minutes. Red - Blinks when error triple tap it again. Error Codes – Red 3. The load will flash and the load control will be returned to factory Help 2. Press and hold the OFF button on the Pico lutron.com settings. wireless control for six (6) seconds until the LED Blink pattern 4. When an in-line fan control is returned to its factory settings, there on the Pico wireless control flashes. Probable Cause is no feedback from the fan load; however, the LED on the device Europe: +44.(0)20.7702.0657 ... ... = on = off 3. When successfully paired, the LEDs on the ... flashes and the fan will turn off. ... ... Asia / Middle East: +97.160.052.1581 in-line load control and the Pico wireless control • Wiring error. Product may be permanently damaged. will flash quickly. The light load on an in-line ... U.S.A. / Canada: 1.844.LUTRON1 ... ... dimmer or switch will also flash. ... • Unsupported load type (dimmer not rated for MLV loads). Limited Warranty: ... Mexico: +1.888.235.2910 4. Press the ON button on the Pico wireless ... www.lutron.com/europe/Service-Support/Pages/Service/Warranty ... ... ... India: 000800.050.1992 control and verify the load control turns on the • Wiring error. load. See the Troubleshooting section if the ... • Load may be shorted. ©2017–2024 Lutron Electronics Co., Inc. ... In-Line Load Control Pico Wireless Control Others: +1.610.282.3800 load does not turn on. ... ... ... • Circuit has too much load. ... Fax: +1.610.282.6311 Lutron, the Lutron logo, HomeWorks, and Pico are trademarks or ... • Circuit has too much load. registered trademarks of Lutron Electronics Co., Inc. in the US ... ... • Inadequate ventilation around in-line control. ... and/or other countries.

Need assistance or looking to source this item?