This document could not be shown here. Open the PDF.
Text of this document7 pages · 1,516 words
Page 1
product specifications 3691084f 01.23.25 HomeWorks In-Line Load Controls The HomeWorks family of in-line dimmers, switches and fan controls can control lighting, motor, and fan loads and provide a system that is convenient and easy to install. HomeWorks in-line load controls use Lutron patented Clear Connect RF technology which provides reliable, wireless communication with other HomeWorks devices. Using a HomeWorks hybrid repeater allows devices to be part of a Control Model Number Frequency Country / whole house solution that can be controlled Type Region remotely from anywhere in the world. Dimmer HQRK-R25NE-240 868 MHz UK, Europe Features Dimmer HQRM-R25NE-240 868 China • The reverse-phase dimmer is trailing-edge capable Limited of up to 250 W of incandescent / halogen / ELV Dimmer HQRN-R25NE-240 865 MHz India 434 Hong loads and up to 1 A / 150 W of LED. Dimmer HQRQ-R25NE-240 Limited Kong, • The switch is rated for 6 AX of general purpose Israel lighting load and 2 A / 0.5 HP of motor load. Switch HQRK-R6ANS-240 868 MHz UK, Europe • The four-speed fan control is rated for a single AC Switch HQRM-R6ANS-240 868 China ceiling fan up to 100 W.** Limited Switch HQRN-R6ANS-240 865 MHz India • When powered on in an unaddressed state (not 434 Hong paired with a Pico remote control or activated in a Switch HQRQ-R6ANS-240 Limited Kong, system), the fan control will turn on the fan for two Israel (2) minutes to allow the installer to verify that the Fan Control HQRN-RNFSQ-240 865 MHz India device is installed and wired correctly. Fan Control HQRK-RNFSQ-240 868 MHz UK • The four fan speed settings (low, medium, medium high, and high) can be adjusted to be faster or slower to optimize each for the specific ceiling fan that is being used. This feature is accessible within the device settings in the Lutron app. • When used with a HomeWorks hybrid repeater*, the load controls can be programmed and controlled via lighting scenes, scheduled daily events, the Lutron Connect app, and other HomeWorks system features. Also, the load controls can be controlled from anywhere in the world. • Small size allows for simple retrofit installation. • Remote device association allows for in-line controls to be added to a system without physically accessing product. * Requires HomeWorks software 14.0 or later. ** Use to control one AC ceiling fan. Not for use with DC motor fans, fans with integrated light control modules, fans with remote controls, or WI-FI only fans. Not for use with shaded-pole type motors (e.g., bathroom or kitchen exhaust-type fans). Customer Assistance: +44.(0)20.7702.0657 (Europe) www.lutron.com/support 1 0800.282.107 (UK)
Page 2
product specifications 3691084f 01.23.25 HomeWorks In-Line Load Controls Specifications Power 220 – 240 V~ 50/60 Hz Typical Power Dimmer / Switch / Fan Control: <0.5 W Consumption Test conditions: Load and LED are off CE (HQRK model only) Regulatory Approvals IDMA (HQRM model only) WPC (HQRN model only) Environment Ambient operating temperature: 0 °C to 40 °C, 0% to 90% humidity, non- condensing. Indoor use only. HomeWorks in-line load controls communicate with the system through Radio Communications Frequency (RF). They must be located within 9 m of a hybrid repeater. System devices operate on 868 MHz, 868 MHz Limited, 865 MHz or 434 MHz Limited frequencies. ESD Protection Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2. Tested to withstand surge voltages without damage or loss of operation, in Surge Protection accordance with IEEE C62.41-1991 Recommended Practice for Surge Voltages in Low-Voltage AC Power Circuits. Power Failure Power failure memory: should power be interrupted, the control will return to its previously set level prior to the interruption when power is restored. Allow adequate space to ensure convective cooling of load control. Remove any insulation, heat generating equipment, or obstructions within 120 mm of the load control. Mounting For optimal RF performance, no metal or other electrically conductive material should be present within 120 mm around the top and sides of the load control. The load control is not suitable for installation in places where it is fully enclosed in metal (e.g., metal enclosures, electrical cabinets) or within metal ceilings. HomeWorks in-line controls accept wire gauges between 2 2 0.5 mm to 2.5 mm . Wiring Note: All outside wire diameters must be the same and must be between 5.2 mm – 8.5 mm. With repeater: Up to 100 devices (e.g., load controls, Pico wireless controls, Radio Powr Savr sensors, shades, and repeaters) are supported per RF link. The processor counts as one device and four locations are reserved for hybrid Device Limits repeaters. Note: Load controls have load type and capacity limits. For more information, see Load Type and Capacity. Warranty www.lutron.com/TechnicalDocumentLibrary/Intl_Warranty.pdf Customer Assistance: +44.(0)20.7702.0657 (Europe) www.lutron.com/support 2 0800.282.107 (UK)
Page 3
product specifications 3691084f 01.23.25 HomeWorks In-Line Load Controls Dimensions All dimensions are shown as: mm 32 153 46 Mounting and Installation All dimensions are shown as: mm I n n s io ula t t ula ion s n I 120 120 105 ø 50 26 Customer Assistance: +44.(0)20.7702.0657 (Europe) www.lutron.com/support 3 0800.282.107 (UK)
Page 4
product specifications 3691084f 01.23.25 HomeWorks In-Line Load Controls Load Type and Capacity Model Voltage Load Types HQRK-R25NE-240 E HQRM-R25NE-240 1 A 250 W – Incandescent, halogen, ELV LV HQRN-R25NE-240 1 A 150 W – LED* LED DEL HQRQ-R25NE-240 HQRK-R6ANS-240 220 – 240 V~ E M HQRM-R6ANS-240 50/60 Hz 6 AX Lighting (all types) LED LV LV DEL HQRN-R6ANS-240 2 A / 0.5 HP Motor M HQRQ-R6ANS-240 HQRN-RNFSQ-240 100 W max. one (1) AC ceiling fan** HQRK-RNFSQ-240 * LED rating is 1 A. If no current rating is specified, a power rating of 150 W can be used. Higher ratings (up to the incandescent rating) can be achieved for specific LED fixtures based on Lutron testing results. Refer to lutron.com/ledtool for compatibility testing results and the maximum number of LED fixtures. Using LED fixtures that are not tested can result in the fixtures not turning on or poor dimming quality. LED dimming performance can vary from fixture to fixture and cannot be guaranteed. ** Use to control one AC ceiling fan. Not for use with DC motor fans, fans with integrated light control modules, fans with remote controls, or Wi-Fi only fans. Not for use with shaded-pole type motors (e.g., bathroom or kitchen exhaust-type fans). Compatible Power Boosters and Load Interfaces Some local controls can be used to control power boosters or load interfaces. Up to three power boosters or load interfaces can be used with one control. See table below for a list of controls and compatible power boosters and load interfaces. Control 0-10 V interface GRX-TVI HQRK-R25NE-240 P HQRM-R25NE-240 P HQRN-R25NE-240 P HQRQ-R25NE-240 P HQRK-R6ANS-240 P HQRM-R6ANS-240 P HQRN-R6ANS-240 P HQRQ-R6ANS-240 P Customer Assistance: +44.(0)20.7702.0657 (Europe) www.lutron.com/support 4 0800.282.107 (UK)
Page 5
product specifications 3691084f 01.23.25 HomeWorks In-Line Load Controls Wiring L = Live = Earth N = Neutral Breaker = Dimmed Live Panel = Switched Live = Fan Live L N / / lutron.com N Load lutron.com Strain relief Customer Assistance: +44.(0)20.7702.0657 (Europe) www.lutron.com/support 5 0800.282.107 (UK)
Page 6
product specifications 3691084f 01.23.25 HomeWorks In-Line Load Controls Operation lutron.com Green - B links when load is toggled Flashes during association Blue - Advanced programming mode (APM) Red - Blinks when error RF Range Hybrid Repeater Radio Powr Radio Powr Savr sensor Savr sensor 9 m Radio Powr maximum Savr sensor Pico Hybrid Repeater Hybrid Repeater Pico Hybrid Repeater wireless Hybrid Repeater Pico Repeater Status Repeater Status Repeater Status Hybrid P 1 2 3 4 P 1 2 3 4 P 1 2 3 4 wireless Communication Communication Communication RF Wired wireless RF Wired control RF Wired Setup Test Activate Setup Test Activate Setup Test Activate Repeater Test Add control Test Add Test Add control Power Repeater Link Power Repeater Link Power Repeater Link 9 V CO 24 MUMU 9 V CO 24 MUMU 9 V CO 24 MUMU M1 V2X3 X4 M1 V2X3 X4 M1 V2X3 X4 Hybrid Repeater Repeater Status P 1 2 3 4 Communication RF Wired Setup Test Activate Test Add Power Repeater Link 9 V CO 24 MU MU lutron.com M1 V2 X3 X4 lutron.com lutron.com In-line load control In-line load In-line load control 9 m 9 m control maximum maximum RF Link RF Link 305 m maximum wire 18 m (60 ft) maximum 305 m maximum length per run wire length per run All devices must be located within 9 m of a hybrid repeater. The range can be extended with up to four HomeWorks hybrid repeaters (HQx-REP) on a single RF link. Customer Assistance: +44.(0)20.7702.0657 (Europe) www.lutron.com/support 6 0800.282.107 (UK)
Page 7
product specifications 3691084f 01.23.25 HomeWorks In-Line Load Controls Model Numbers HQRX-RXXXX-240 Frequency / Device Type Channel Code Frequency / Channel Code K = 868 MHz M = 868 MHz Limited N = 865 MHz Q = 434 MHz Limited Device Type 6ANS = Switch (Neutral Required) 25NE = Dimmer (Neutral Required) NFSQ = Fan Control (Neutral Required) Lutron, Pico, HomeWorks, Radio Powr Savr and Clear Connect are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. Customer Assistance: +44.(0)20.7702.0657 (Europe) www.lutron.com/support 7 0800.282.107 (UK)
Need assistance or looking to source this item?