EDIT CUSTOM PROPERTIES 29. TITLE TO DESIRED PIC SP 3 PRODUCT CODE PICTURE SPLIT MECHANISM 30. SUBHEADING TO DESIRED PRODUCT DESCRIPTION EDIT CUSTOM PROPERTIES TECHNICAL SHEET 31. ISSUE NO. UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 004 TO DESIRED ISSUE NUMBER WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
PIC SP 3 PICTURE SPLIT MECHANISM SPECIFICATION MEASUREMENTS Maximum Screen Size 65" (1650mm) Maximum Weight Capacity 15Kg (33lb) per Panel Maximum Speed 120mm/s Maximum Travel 1650mm (65.0") Depth From Wall 50mm (2.0") Product Weight 18.5Kg (40.8lb) per Mechanism Packaging Dimensions 107cm x 103cm x 36cm (42.12" x 40.55" x 14.17") Shipping Weight 64Kg Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption Max. 110W Power Consumption Standby 3W Control Options IR Remote, RS232, Contact Closure Product Options / Features Custom RAL paint finishes Package Contents Mechanism, IR remote control Marine Suitable No TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 004 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
PIC SP 3 PICTURE SPLIT MECHANISM RECESS DETAILS Fully lined recess for the screen. The front of the screen can be flush with the CABLES: wall surface or set slightly back. During installation, cables between the two mechanisms shall be required to run to a suitable storage location; connecting to the control box O (308[12.2] x 150[5.9] x 52[2.1]). 3/8" A nominal 40mm[1.6] cable entry/exit hole is 10 recommended to provide suitable access for cable routing. The control box shall need to be connected into a mains (13A) plug socket. An infrared receiver on a 1.5m[59.1] lead is also plugged into the control box. PANELS: The moving panels shall be 10mm[0.4] proud of the wall surface. NOTE: 1650mm[65.0] is the widest recess this version of the mechanism can cover. This dimension can be reduced for small recesses but not increased. 64 15/16"
1650
66 15/16"
1700
TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 O ISSUE 004 WWW NET . . SHEET 3 FUTUREAUTOMATION SECTION O-O
Page 4
PIC SP 3 PICTURE SPLIT MECHANISM 1 3/4" 45 PANEL DETAILS These are suggested dimensions for the panels. The panels must have an internal depth of 45mm to conceal the mechanism; as shown in DETAIL B.
1" 25
DETAIL B 40 9/16" 38 9/16"
980 1030
A B 40 9/16" 38 9/16" 1030 980 64 15/16"
1650
146 1/16"
3710
SECTION A-A A TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 004 WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
PIC SP 3 PICTURE SPLIT MECHANISM PANEL MOUNTING DETAILS D C Panel mount plates hook onto two bolts. The height of the bolts can be adjusted to ensure the panels are level. DETAIL D One side of Picture Split mechanism shown; other side omitted for clarity. Mechanisms supplied as a pair. Mount plates fasten to the top, inside face of the panels (2 positions) as DETAIL C shown. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 004 WWW NET . . SHEET 5 FUTUREAUTOMATION
Page 6
PIC SP 3 PICTURE SPLIT MECHANISM PANEL TRAVEL DETAILS The maximum travel distance is 825 [32.5] per panel. This accommodates for the MAX recess width for the PIC SP 3(1650[65.0])
32 1/2" 825 MAX 64 15/16" TECHNICAL SHEET 1650 MAX UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 004 WWW NET . . SHEET 6 FUTUREAUTOMATION
Page 7
PIC SP 3 PICTURE SPLIT MECHANISM 66 15/16" 1700 MOUNTING DETAILS 36 7/16" 36 7/16" These are suggested dimensions for positioning the 925 925 mechanisms on the wall. The dimensions are based around the panel sizes stated on Page 4. 33 7/16" 850 1" 25 Mechanisms mount onto the wall 5 5/16" surface and fastened into 135 position. 6mm[0.2] slots are provided to aid installation. 17 1/2" 445 9 1/4" 235 3 3/8" 85 0" 36 5/8" 0 930 3 3/8" 3 3/8" 85 85 1 9/16" Cable entry/exit hole 40 nominal hole recommended TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 004 WWW NET . . SHEET 7 FUTUREAUTOMATION
Page 8
PIC SP 3 PICTURE SPLIT MECHANISM CONTROL BOX DETAILS • Power Supply Unit (PSU) will allow 110V or 240V AC input. The same PSU is used for EU or US mains supplies. • Other than control cables, all cables terminate at the control board via standard phoenix connnectors. • Cable loom length supplied at approx. 4m [158"]. Loom can be extended to a maximum of approx. 10m [400"]. 2 1/16" • Minimum cable bend radius 25mm [1"]. 52 RS232 PORT CONTACT CLOSURE PORT EMERGENCY STOP CONNECTOR IR LEAD INPUT 3.5mm [1/8"] JACK 12 1/8" 308 IR OUTPUT INDICATOR LED 3 Cables lead from bracket to control box 1/4" 5/16" 7 8.2 11/16" 17 AC Mains IN 5 7/8" 150 3/16" 5.2 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 004 WWW NET . . SHEET 8 FUTUREAUTOMATION