Page 1

Instruction Manual RMR-VF Wireless 10-Way Volt-Free Interface 2024 Version 2.2.0

Page 2

For more information relating to the RMR-VF see the Wireless Module Application Sheet, Wireless RAK Application Sheet, and Wireless Device LED Diagnostics. For programming a Wireless system, including the device in this manual: Wireless Module Programming Guide Contents 1WhatistheRMR-VF? 2Inputs 3Installation 4ProgrammingtheRMR-VF 4.1 Assigning the RMR-VF 4.2 Configuring the RMR-VF 4.2.1 The Mapping Section 4.2.2 Inputs 4.2.3 Mapping Options 4.2.4 Input action 1WhatistheRMR-VF? TheRMR-VFisa10-wayvoltfreeinterface programmable via Rasoft Pro using a programming device such as a RAMPIorHUB. Each input can be programmed to its own Room and Channel, and each input has two states, ‘on make’ and ‘on break’ which can be configured to trigger a command for each state that the switch is in. Example: OnMake=Scene1 OnBreak=Off 2Inputs UptoteninputscanbeusedontheRMR-VF,iftheinputsarefully populated it is recommendedtouseallthreecommoninputstoavoidexceedingtheinputterminal capacities. RMR-VF Manual Version 2.2.0

Page 3

3Installation POWERSHOULDBEISOLATEDTHROUGHOUTTHEINSTALLATIONPROCESS RMR-VFmodulesshouldbemountedinareasthatareadequatelyventilated, dry, andoutside of any metal-enclosed casings that may interfere with the wireless signal. Modulesshouldbemountedvertically, with the terminals at the bottom. Ensurethat cable clamps are securely fitted on the incoming cables. Whilethemodulesaredesignedtobecompletelymaintenance-free, they should be mountedinanaccessible location should investigation or re-addressing of the units benecessary. STEP1 Removethefront cover andset the cable clamps aside. STEP2 Insert the DC power connector. NB Apowersocketis required for the power supply. RMR-VF Manual Version 2.2.0

Page 4

STEP3 Connect the common andswitching wires to the required inputs, there can be up to ten per RMR-VR. Theexampleshowsa commonwiring arrangement. STEP4 Install the cable clamps, andensure that the connected cables are secure. RMR-VF Manual Version 2.2.0

Page 5

4ProgrammingtheRMR-VF Before the RMR-VF can function, it has to be programmed via Rasoft Pro using a programming device such as the RAMPI or HUB. Thefollowing steps assume: - AProject File has been created. - Roomshavebeencreated. - TheHUBhasbeenconfigured. - TheChannels in the Rooms have been labelled. If the above has not been done, refer to the Wireless Module Programming Guide before continuing. 4.1 Assigning the RMR-VF - Select “File” - “New device” to bring up the “New device Wizard” - Select “RMR-VF” and then select “Next”. RMR-VF Manual Version 2.2.0

Page 6

- Chooseadescriptive name for the Device and select “Next” - Associate the RMR-VF with a Room using the drop-down menu, leave “Associate to Channel” as it is and select “Next” - Put the RMR-VF into Setup Mode by pressing and holding the setup button on the unit for 3-4 seconds. - OncetheRMR-VFhasenteredSetupMode,theblueLEDontheunitwillblink periodically, select ‘Device is in Setup’, then ‘Finish’ RMR-VF Manual Version 2.2.0

Page 7

- TheRMR-VFhasbeenassignedinRasoftPro,itcanbeaccessedbyselecting it in the “Device List” 4.2 Configuring the RMR-VF OncetheRMR-VFhasbeenassignedtoaRoominRasoftPro,theinputsrequire programming via the Device Editor. To get to the RMR-VF configuration page, select it in the Device List as seen in the previous step. 4.2.1 The Mapping Section All programmed inputs for the Device must first have a mapping. The purpose of a mappingis to program an input to perform a specific command. Each input has its own letter to represent its input; the RMR-VF has up to 10 inputs. Newmappingscanbecreatedbyselectingadisabledfieldandselecting the corresponding input letter in the next column. RMR-VF Manual Version 2.2.0

Page 8

Active mappings can be copied or pasted into disabled mappings; this is typically used whenre-using similar functions of an existing mapping to save time such as a toggle function. Mappingright-click options 4.2.2 Inputs Theinputs for the mappings are configured in the Inputs section. Whenaninputishighlighted blue, it will set the corresponding input letter active in the mapping, selecting the input multiple times will cycle through the input options which are “Normal”, “Ignore” and “Invert”, an example can be seen below: ‘A - Normal’ creates a mapping for input A, ensure that only one input is highlighted blue for each mapping. If A is set as ‘Invert’, the ‘On Make’ and ‘On Break’ commands will reverse. 4.2.3 Mapping Options Oncetheinputhasbeenselectedandconfigured,thebehaviouroftheinput is set up in the Mapping Options. RMR-VF Manual Version 2.2.0

Page 9

Trigger on Make Whentheswitchinput makes contact, trigger the output command. Trigger on Break Whenaswitchbreaksits contact, trigger the output command. SendStopOnRelease Whenthemadecontactisreleased, a ‘Stop’ command will be triggered. Trigger on Press Trigger the output command when the momentary switching makes contact between its input and common. Trigger on Release Trigger the output command when the momentary switch breaks contact between its input andcommon. Don't update previous room If this box is ticked this map will not update the “last used” flag for both Room and Channel. When a “last used” is sent from this Device the most recent room and Channel sent which doesn't have “don't update previous Room” selected will be sent. Set Scenes only if lights are OFF: Thecommandsentinthe“outputaction”section is a scene that will only take effect if the lights are currently off. This is often used when the device interfacing with the RMR-VF is a presence sensor. RMR-VF Manual Version 2.2.0

Page 10

Anyinput Trigger (OR Logic): Useonly when combined inputs are required. 4.2.4 Input action Room TheRoomnumberoftheoutputcommand. Channel TheChannelnumberoftheoutputcommandcanbeAllChannelsorasingleChannel. Disable map Whenenabled,thebuttoninput will have no output command. Scene If a Scene is being triggered, select a Scene between 1-16. Fade-Up/Fade-Down Commonlyusedtomanuallydimlightingupanddown,aswellastheOpening/Closingof Blinds. NB ‘Send Stop on Release’ should also be checked when using this option. MotorStop Usedtostop3rdpartymotorsthat are configured within the HUB. Ident This option is not recommended, as the command will make a load flash momentarily and provides no practical function for daily use. RMR-VF Manual Version 2.2.0

Page 11

Toggle TheTogglefunction will alternate between two commands, either a Level command and Off, or a Scene command and Off. NB DonotmapmorethanoneToggletoasinglebuttonontheinputs;thiswillresult in sporadic switching due to toggles getting out of sync. Level Sets the lighting Level to a percentage of brightness between 0-100%. RMR-VF Manual Version 2.2.0