This document could not be shown here. Open the PDF.
Text of this documentPages 1 to 43 of 178 · 8,144 words
Page 1
HomeWorks® Technical Reference Guide International Edition (220-240 V) |Rev H
Page 3
Table of Contents INTRODUCTION BACK ROOM EQUIPMENT Introduction to HomeWorks . . . . . . . . . . . . . . .2.1 Power MModules aand RRemote PPower PPanels . . . .6.1 ® Features . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.4 Wallbox Power Module . . . . . . . . . . . . . .6.2 INTRODUCTION Remote Power Modules . . . . . . . . . . . . . .6.6 SYSTEM DESIGN Module Interface . . . . . . . . . . . . . . . . . .6.12 Design OOverview . . . . . . . . . . . . . . . . . . . . . .3.2 Remote Power Panels Centralised Design . . . . . . . . . . . . . . . . .3.3 Without Breakers . . . . . . . . . . . . . . . .6.16 Localised Design . . . . . . . . . . . . . . . . . .3.4 With Breakers . . . . . . . . . . . . . . . . . .6.20 Hybrid Design . . . . . . . . . . . . . . . . . . . .3.5 Power BBoosters aand IInterfaces . . . . . . . . . . . .7.1 Series OOverview . . . . . . . . . . . . . . . . . . . . . . .3.6 FDBI . . . . . . . . . . . . . . . . . . . . . . . . . .7.6 4 Series System Layout . . . . . . . . . . . . .3.8 0-10 V Interface . . . . . . . . . . . . . . . . . .7.7 8 Series System Layout . . . . . . . . . . . . .3.9 TVM Dimming Kit . . . . . . . . . . . . . . . . .7.9 4 Series System Wiring Ten Volt Module . . . . . . . . . . . . . . . . . .7.13 and Communication . . . . . . . . . . . . . . . .3.10 LUT-DMX . . . . . . . . . . . . . . . . . . . . . . .7.14 8 Series System Wiring Contact Closure Interface . . . . . . . . . . . .7.18 and Communication . . . . . . . . . . . . . . . .3.12 Processors . . . . . . . . . . . . . . . . . . . . . . . . . .8.1 System Specifications . . . . . . . . . . . . . .3.14 8 Series Processors . . . . . . . . . . . . . . . .8.8 FRONT ROOM EQUIPMENT 4 Series Processors . . . . . . . . . . . . . . . .8.12 Low-voltage EEnclosures . . . . . . . . . . . . . . . . .9.2 Local CControls . . . . . . . . . . . . . . . . . . . . . . . .4.1 Wireless EEquipment . . . . . . . . . . . . . . . . . . . .10.1 Rania® RF . . . . . . . . . . . . . . . . . . . . . . .4.2 Hybrid Repeater . . . . . . . . . . . . . . . . . .10.2 Maestro® . . . . . . . . . . . . . . . . . . . . . . .4.10 Wireless Tabletop Keypads . . . . . . . . . . .10.5 GRAFIK Eye . . . . . . . . . . . . . . . . . . . . .4.16 ® Transformers . . . . . . . . . . . . . . . . . . . . .10.7 GRAFIK Integrale® . . . . . . . . . . . . . . . . .4.22 Sivoia QQED . . . . . . . . . . . . . . . . . . . . . . . . . .11.1 Keypads aand CContact CClosures . . . . . . . . . . . .5.1 ® Other EEquipment . . . . . . . . . . . . . . . . . . . . . .12.1 International seeTouch® . . . . . . . . . . . . .5.4 Link Extender . . . . . . . . . . . . . . . . . . . .12.2 Dual International seeTouch . . . . . . . . . .5.7 Auxiliary Power Supplies . . . . . . . . . . . . .12.4 seeTouch . . . . . . . . . . . . . . . . . . . . . . .5.9 Electric Low-voltage Transformers . . . . . .12.8 European-style . . . . . . . . . . . . . . . . . . .5.14 Wire Landing Board . . . . . . . . . . . . . . . .12.11 Slim Button . . . . . . . . . . . . . . . . . . . . .5.17 Colours aand FFinishes . . . . . . . . . . . . . . . . . . .13.1 Large Button . . . . . . . . . . . . . . . . . . . .5.18 Signature SeriesTM . . . . . . . . . . . . . . . . .5.21 ArchitraveTM . . . . . . . . . . . . . . . . . . . . .5.22 Engraving with Icons . . . . . . . . . . . . . . .5.25 Wallbox Closure Interface . . . . . . . . . . . .5.26 Web Keypads . . . . . . . . . . . . . . . . . . . .5.28 Keypad Specifications, Addressing and Dimensions . . . . . . . . . . . . . . . . . . . . . .5.29 Technical Support: hwisupport@lutron.com 1.1
Page 5
INTRODUCTION Introduction Technical Support: hwisupport@lutron.com 2.1
Page 6
Introduction to HomeWorks ® INTRODUCTION The most powerful and most flexible DESIGN AND CONTROL FLEXIBILITY lighting control system in the world HomeWorks systems are very flexible. Solutions exist HomeWorks, the world’s leading residential lighting for residences of any size. control and integration system, provides simple, After the installation, keypads may be easily convenient control of all home lighting, as well as the reconfigured to accommodate new control ability to control motorised shades and curtains, and requirements. many other systems in a home. HomeWorks provides many benefits. ADDED CONVENIENCE • Increased security Control any light in a home from any HomeWorks • Design and control flexibility keypad. This eliminates the tedious task of walking • Added convenience around the home to set the right lighting for daily activities or special occasions. • Improved aesthetics • Energy savings INCREASED SECURITY HomeWorks seamlessly integrates with home security systems. In the event of an alarm, interior lights turn on, illuminating a safe exit, while exterior lights flash, thereby drawing immediate attention. HomeWorks provides security by allowing clients to turn all lights on instantly from a single button press. HomeWorks makes a home safer by automatically turning on landscape and security lighting each night. A built-in astronomical timeclock intelligently adjusts for changing sunrise and sunset times throughout the year. Every day, a HomeWorks system automatically records the home’s lighting usage patterns. These patterns can be replayed when the home is unoccupied. This unique feature allows for a realistic simulation of activity that standard timers cannot provide. www.lutron.com 2.2
Page 7
Introduction to HomeWorks ® IMPROVED AESTHETICS HomeWorks gives clients the power to enhance the beauty of their home and decor with a variety of INTRODUCTION customised room and whole-house lighting scenes. One button press can dim the lights for a romantic dinner while another button press lights the house for a festive party. Keypads provide a clean, elegant look on the wall by combining the functions of many standard switches International seeTouch and dimmers into a single control. ® Lutron® combines a large selection of controls with an extensive array of colours and finishes. HomeWorks keypads are available with custom engraving. seeTouch keypads provide a unique backlighting ® feature whereby engraving is readable in the dark. seeTouch tabletop keypad seeTouch keypad Custom faceplates - combination of seeTouch and Russound® audio control Technical Support: hwisupport@lutron.com 2.3
Page 8
Features INTRODUCTION LUTRON QUALITY SECURITY Lutron® has been the world leader in lighting controls Connect HomeWorks to a security system to activate since inventing the solid-state dimmer in 1961. All lights in case of an alarm. Selected lights will turn on Lutron products are designed and manufactured to the to a predetermined security level, while others flash highest quality standards. All HomeWorks systems are repeatedly to attract attention. Security mode may also ® covered by an 8-year limited warranty. Lutron was one be activated manually from a keypad. When security of the first 20 companies in the US to earn the ISO mode is deactivated, the lighting returns to the 9001 international quality certification, and today original levels set before security mode was activated. Lutron is ISO 9001:2000 certified. AESTHETIC CONSISTENCY FAIL-SAFE OPERATION HomeWorks keypads and local lighting controls HomeWorks local lighting controls and GRAFIK Eye complement each other with matching colours, styles, ® preset local lighting controls remain fully functional and finishes. Elegant faceplates can also be customised even in the unlikely event communication to the to match a home’s paint, wallcoverings, or decor. processor is interrupted. Dimming panels also have manual override capabilities, which can be activated ENERGY SAVINGS from dedicated switches located anywhere in the home. The HomeWorks system makes it easier than ever POWER-FAILURE MEMORY to consume less. Using Lutron dimmers not only extends lamp life but can reduce your average All HomeWorks components are designed with 10-year lighting consumption by up to 40%. With built power-failure memory. If power is interrupted in green features such as scene Rollback and temporarily and restored, lights will automatically load trimming, your home can be programmed return to the levels to which they were set prior to intelligently manage its lighting by turning off to the power outage. unused circuits and trimming power used on other circuits during peak hours. Your home has different lighting needs during the day versus the night. With HomeWorks, we can make sure you have the perfect lighting at anytime without wasting energy on unneccessary lights. www.lutron.com 2.4
Page 9
Features ASTRONOMICAL TIMECLOCK CONDITIONAL LOGIC HomeWorks® can automatically trigger events at HomeWorks provides the capability to activate specific times of the day or at times relative to sunrise events only if specific conditions are met. For INTRODUCTION or sunset. Program multiple schedules allowing for example, program driveway sensors to turn on different timeclock events on weekdays, weekends, exterior lighting only if it is dark. A single “dining” holidays, etc. Enable or disable timeclock schedules button could set different lighting and music for from any keypad. Additionally, any timeclock event breakfast, lunch, and dinner. can be programmed using conditional logic, so the event will occur only if a specified condition is met. PROGRAMMING FLEXIBILITY VACATION MODE HomeWorks keypads can be customised to meet customers’ changing needs. Each keypad button may HomeWorks constantly monitors and records the state be programmed to activate any of the lights in the of all lighting in a home. When vacation mode is system. Keypad buttons may also be programmed to activated, the system plays back these events, control audio, video, shades, curtains, and other providing a realistic appearance of activity while the integrated systems. home is unoccupied. The system can be programmed to record the last day’s, the last week’s, or the last BACKLIT KEYPADS two weeks’ activities. HomeWorks seeTouch and Signature SeriesTM keypads ® INTEGRATION have backlighting so that the button labels can easily be read in a dark room. HomeWorks has been designed to integrate with audio, video, and other systems in a home. A typical application includes control of an audio system from REMOTE CONNECTION AND CONTROL buttons on a HomeWorks Keypad. Interface the system The HomeWorks system features the ability to support with other equipment using contact closure inputs and a remote connection by utilising the home's existing outputs, infrared inputs, RS-232 serial communication, Ethernet network. Once configured by a professional, and ethernet. the system can be updated and even monitored from any location around the world. With such flexibility, you can now take peace of mind with you as the HomeWorks system even integrates with several mobile devices such portable phones and computers. Technical Support: hwisupport@lutron.com 2.5
Page 10
Notes INTRODUCTION www.lutron.com 2.6
Page 11
System Design STEM DESIGN Y S Technical Support: hwisupport@lutron.com 3.1
Page 12
Design Overview System design begins with drawings of the home. The system design depends on customer requirements and the home’s lighting (load types, wattages and quantity). HomeWorks has multiple system design options: ® CENTRALISED DESIGN Centralised designs place dimming equipment in remotely mounted panels. All lights are controlled from keypads, providing maximum flexibility, while minimising the number of controls on the wall. S LOCALISED DESIGN Y STEM DESIGN Localised designs place dimming components in or near the room they are controlling. Local dimmers provide simple and easy control for small rooms. In large rooms where several local dimmers would be unsightly, locally mounted wallbox dimming modules are used instead. Wallbox dimming modules can be placed in nearby closets, cupboards, and utility rooms, and controlled from keypads in the room. HYBRID DESIGN Hybrid designs combine the benefits of both centralised and localised designs. This maximises ease of use, while minimising excessive controls on the walls. www.lutron.com 3.2
Page 13
Centralised Design A centralised design uses Remote Power Modules to Each power panel has manual override control control all lighting loads. The Remote Power Modules providing “fail-safe” operation in the unlikely event are mounted in power panels, located in equipment communication to the processor is interrupted. rooms or electrical closets. The clients control the lights from keypads, providing maximum flexibility CENTRALISED DESIGN SUMMARY: while minimising the number of controls on the wall. Keypads have the ability to perform any function from •Minimises the number of controls on the wall control of a single light to control of every light. •Direct control of AC motors Remote Power Modules, located in power panels support •Maximum control flexibility large loads and a wide range of load types including incandescent, magnetic low-voltage, electronic low- •Minimises need for Power Boosters or interfaces voltage and neon/cold cathode. Remote Power Modules •Manual override control provides “fail-safe” operation can also provide direct control of AC motors for shades, draperies, and curtains and other non-lighting equipment such as exhaust fans and pumps. STEM DESIGN Y S Kitchen Master Bath Bath Bedroom Family Room Study Foyer Master Bedroom Dining Living Garage Room Room Keypad Remote Power Module Processor Technical Support: hwisupport@lutron.com 3.3
Page 14
Localised Design A localised design uses local lighting controls (Rania® Localised dimming components provide clients RF dimmers, Maestro® dimmers and switches, Wallbox with “fail-safe” operation. If communication to the Power Modules, and GRAFIK Eye® preset controls) to processor is interrupted, the local lighting controls dim lighting loads. Local dimmers provide simple and continue to operate as normal. easy to use control. In areas with several lights, Rooms of the house that have been pre-wired for local remotely mounted Wallbox Power Modules are used lighting control can be easily added to the system at instead. The Wallbox Power Modules are placed in a later date. This is ideal for the client who wants to nearby closets, cupboards, and utility rooms. start with a basic system and expand it later. Keypads provide control of Wallbox Power Modules, as well as control of GRAFIK Eye and Maestro dimmers LOCALISED DESIGN SUMMARY: throughout the home. In this design, keypads are typically installed in locations such as entryways, •Easy to use controls S Y master bedrooms, and key entertaining rooms. STEM DESIGN •“Fail-safe” operation •Pre-wire compatible Kitchen Master Bath Bath Bedroom Family Room Study Foyer Master Bedroom Dining Living Garage Room Room Keypads Wallbox Power Module Local dimmers Power Booster/interface GRAFIK Eye® Processor www.lutron.com 3.4
Page 15
Hybrid Design A hybrid design for HomeWorks® combines the benefits HYBRID DESIGN SUMMARY: of both centralised and localised designs. Typically, •Easy to use controls local lighting controls are used in smaller rooms where simple controls are desired. In larger rooms, lighting •Direct control of AC motors loads are typically wired to remote dimming components. •Maximum control flexibility Keypads are placed throughout the home, providing control wherever it is desired. •Minimises need for Power Boosters or interfaces In this design, areas of the house that have been •“Fail-safe” operation pre-wired can be easily added to the system at a later •Pre-wire compatible date. This is ideal for the client who would like to start with a basic system and then expand it later. STEM DESIGN Y S Kitchen Master Bath Bath Bedroom Family Room Study Foyer Master Bedroom Dining Living Garage Room Room Keypads Wallbox Power Module Local Dimmers Remote Power Module GRAFIK Eye Processor ® Technical Support: hwisupport@lutron.com 3.5
Page 16
Series Overview 8 SERIES 4 SERIES The 8 series is used when a centralised or hybrid The 4 series is used when a localised system design system design is desired. It provides the most is desired. The 4 series is usually the lowest cost flexibility in design and integration capabilities. solution but sometimes requires Power Boosters The 8 series has components which support higher and interfaces. wattage loads, the widest range of load types, and direct AC motor control. S 8 series 4 series Y STEM DESIGN System centralised yes no designs localised yes yes supported hybrid yes yes dimming panels yes no Dimming Wallbox yes yes capability Power Modules local lighting yes yes controls typical 20 to 256 20 to 96 Control capability zone count (256 maximum) (256 maximum) per processor typical 5 to 40 5 to 20 keypad count (96 maximum) (96 maximum) motor control direct thru interface RS-232 integration 2 ports / processor 1 port / processor Integration ethernet 1 port / processor 1 port / processor capability input and output contact closures yes yes Sivoia QED® yes yes signal repeaters 5 per processor 5 per processor Wireless tabletop keypads 32 per system 32 per system capability wireless dimmers 64 per processor 64 per processor www.lutron.com 3.6
Page 17
STEM DESIGN Y S Technical Support: hwisupport@lutron.com 3.7
Page 18
4 Series System Layout GRAFIK Eye® S Y STEM DESIGN Wallbox Power Modules 4 Series Processor Dimmers Switches Ethernet link Other equipment through RS-232 Keypads Hybrid Signal Repeater Tabletop Keypad Sivoia QED ® Wireless Dimmers Shades and Draperies www.lutron.com 3.8
Page 19
8 Series System Layout Remote Power Panels GRAFIK Eye® 8 Series Processor Wallbox Power Modules STEM DESIGN Y S Dimmers Switches Ethernet link Other equipment through RS-232 Keypads Hybrid Signal Repeater Tabletop Keypad Sivoia QED ® Shades and Draperies Wireless Dimmers Technical Support: hwisupport@lutron.com 3.9
Page 20
4 Series System Wiring and Communication 4 series HomeWorks processor Maximum total zones per HomeWorks® processor is 256 Enlarged view of processor Label S Y STEM DESIGN Wire type B maximum Wire type A Connect to 15 m maximum other devices (50 feet) 305 m and home total (1,000 feet) networks using point-to- total standard point daisy-chain ethernet cable. To additional processors. 16 maximum per HomeWorks system. Connect to audio, home automation, and other devices controlled using RS-232. www.lutron.com 3.10
Page 21
Tabletop keypad Wire Type Key 32 per system 2 2 Wireless Type A: Two pair [one pair 1.0 mm (18 AWG), one pair 1.0 to 0.5 mm (18-22 AWG) twisted dimmers shielded] Class 2/PELV wire. Lutron® wire model GRX-CBL-346S-500 may be used. 64 per wireless Type B: Standard RS-232 Cable (all pins straight through). link 2 Signal Repeater Type C: One pair 1.0 to 0.5 mm (18-22 AWG) twisted shielded Class 2/PELV wire. 5 per wireless link Wire type A maximum 10 keypads per home run maximum 305 m (1,000 feet) per home run GRAFIK Eye control units/ maximum 1220 m (4,000 feet) total wire length. ® Any configuration. Wallbox Power Modules To additional GRAFIK Wire type A Eye control units/ Wallbox Power Modules maximum 610 m (2,000 (maximum 8 per link). Links 4, 5, and 6 can be feet) total configured to control any of daisy-chain STEM DESIGN the following: HWI-ENC-CC Y S Contact GRAFIK Eye control units/ Closure Wallbox Power Modules Keypads enclosures To additional keypads/ Keypads/ Contact Closure boards Contact Closure Boards (maximum 32 devices per link). Dimmer Interfaces/Q96 HWI-CCI-8 Contact HWI-CCO-8 Contact Closure Input board Closure Output board (wire inputs from (wire outputs to Wire type A driveway sensors, shades, screens, gates, maximum 305 m (1,000 photocells, security spas, thermostats, feet) total systems, etc.) etc.) daisy-chain Maestro® local lighting controls HWI-LV17-230 Low-voltage enclosure HWI-H48 To additional Maestro controls. dimmer Maximum 8 Maestro controls per bus. interface Maximum 6 buses per HWI-H48 (total maximum is 48 Maestro controls per HWI-H48). To maximum of 96 Wire type C- maximum 150 m Sivoia QED® drive units. (500 feet) per wire run. Maximum 305 m (1000 feet) total per bus. Any configuration. To additional HWI-H48 or HWI-Q96 interfaces. Maximum 4 interfaces per link. Technical Support: hwisupport@lutron.com 3.11
Page 22
8 series System Wiring and Communication Maximum total zones per 8 series HomeWorks® processor HomeWorks processor is 256 Enlarged view of processor Label S Y STEM DESIGN Connect to other devices and home networks using Wire type A standard ethernet maximum cable. 305m (1,000 feet) total daisy-chain Wire type B To additional maximum 15m processors. 16 (50 feet) total maximum per system. point-to-point Connect to audio, home HWI-PNL-8-CE automation, and other Remote devices controlled using Power Panel RS-232. PBK8-40-13-10-CE or Wire type A PBK8-40-10-CE Remote maximum 305 m Remote Power Panels (1,000 feet) total Power daisy-chain Modules HWI-PNL-5-CE Remote Power Panel LUT-DMX HWI-MI-230 Module Interface To additional Module Interfaces. Maximum per Module Interface Link is 16 www.lutron.com 3.12
Page 23
Tabletop keypad 32 per system Wire Type Key 2 2 Type A: Two pair [one pair 1.0 mm (18 AWG), one pair 1.0 to 0.5 mm (18-22 AWG) twisted shielded] Class 2/PELV wire. Lutron® wire model GRX-CBL-346S-500 may be used. Type B: Standard RS-232 Cable (all pins straight through). Wireless 2 dimmers 64 per Type C: One pair 1.0 to 0.5 mm (18-22 AWG) twisted shielded Class 2/PELV wire. wireless link Signal Wire type A Repeater maximum 10 keypads per home run 5 per maximum 305 m (1,000 feet) per home run wireless maximum 1220 m (4,000 feet) total wire length. GRAFIK Eye control units/ link Any configuration. ® Wallbox Power Modules Link 8 only To additional GRAFIK Wire type A Eye control units/ Wallbox Power Modules maximum 610 m (2,000 (maximum 8 per link). Links 4, 5, and 6 and 8 can feet) total STEM DESIGN be configured to control any daisy-chain Y of the following: HWI-ENC-CC S Contact GRAFIK Eye control units/ Closure Wallbox Power Modules Keypads Enclosures To additional keypads/ Contact Closure boards Keypads/ (maximum 32 devices Contact Closure Boards per link). Dimmer Interfaces/Q96 HWI-CCI-8 Contact HWI-CCO-8 Contact Closure Input board Closure Output board (wire inputs from (wire outputs to Wire type A driveway sensors, shades, screens, gates, maximum 305 m photocells, security spas, thermostats, (1,000 feet) total systems, etc.) etc.) daisy-chain Maestro® local lighting controls HWI-LV17- 230 Low-voltage enclosure HWI-H48 dimmer To additional Maestro controls. interface* Maximum 8 Maestro controls per bus. Maximum 6 buses per HWI-H48 (total maximum is 48 Maestro controls per HWI-H48). To maximum of 96 Wire type C- maximum 150 m Sivoia QED® drive units. (500 feet) per wire run. Maximum 305 m (1000 feet) total per bus. Any configuration. To additional HWI-H48 or HWI-Q96 interfaces. Maximum 4 interfaces per link. Technical Support: hwisupport@lutron.com 3.13
Page 24
System Specifications Maestro® local lighting Wired Keypad capacities controls capacities Maximum number of devices Maximum number of Maestro Local per keypad link 32 lighting controls per dimmer Maximum number of keypad links interface (H48) bus 8 per processor 3 Number of buses per H48 6 Maximum number of keypads Maximum number of Maestro Local per processor 96 lighting controls per H48 48 Maximum number of processors Maximum number of H48 and Q96 per system 16 interfaces per processor link 4 Maximum number of keypads Maximum number of Maestro local per system 1,536 S Y lighting controls per processor H48 link 192 STEM DESIGNMaximum number of H48 links per processor 1 Maximum number of Maestro Local Wireless capacities lighting controls per processor 192 Maximum number of Hybrid Maximum number of processors signal repeaters per processor 5 per system 16 Maximum number of tabletop Maximum number of Maestro Local keypads per system 32 lighting controls per system 3,072 Maximum number of wireless dimmers per wireless link 64 Sivoia QED® capacities Maximum number of H48 and QED links per processor 1 Maximum number of H48 and QED interfaces per processor 4 Maximum number of Sivoia QED drives per Q96 interface 96 Maximum number of Sivoia QED drives per system 4096 www.lutron.com 3.14
Page 25
System Specifications 8 series processor communication link specifications Maximum per Baud Wiring Termination Link type processor rates configuration required 1 Module Interface 1 125 K daisy-chain yes, at last MI on link inter-processor 1 125 K daisy-chain yes, at both ends of link1 GRAFIK Eye /WPM 3 31.25 K daisy-chain no ® RS-232 2 9600-115.2 K point-to-point no keypad 3 10.42-41.67 K any no H48 and Q96 1 125 K daisy-chain yes, at both ends of link1 interface Hybrid Signal 1 125 K daisy-chain no Repeater 1 Terminators required if total cable length exceeds 15 m (50 feet). 4 series processor communication link specifications Maximum per Baud Wiring Termination STEM DESIGN Link type processor configuration required Y rates S inter-processor 1 1 125 K daisy-chain yes, at both ends of link RS-232 1 9600-115.2 K point-to-point no keypads 3 10.42-41.67 K point-to-point no GRAFIK Eye/WPM 3 31.25 K daisy-chain no H48 and Q96 1 1 125 K daisy-chain yes, at both ends of link interface Hybrid Signal 1 125 K daisy-chain no Repeater 1 Terminators required if total cable length exceeds 15 m (50 feet). Remote Power Module GRAFIK Eye/WPM capacities (RPM) capacities Maximum number of GRAFIK Eye control Number of zones per RPM 4 units/WPM per GRAFIK Eye link 8 Maximum number of RPMs Maximum number of GRAFIK Eye per Module Interface (MI) 8 accessory controls per GRAFIK Eye link 15 Maximum number of MIs per MI link 16 Maximum number of GRAFIK Eye Maximum number of MI links links per processor 3 per processor (8 series only) 1 Maximum number of GRAFIK Eye control Maximum number of RPMs units/WPM per processor 24 per processor (8 series only) 128 Maximum number of GRAFIK Eye accessory Maximum number of RPM zones controls per processor 45 per processor (8 series only) 256 Maximum number of processors Maximum number of processors per system 16 per system 16 Maximum number of GRAFIK Eye control Maximum number of RPMs per system 2,048 units/WPM per system 384 Maximum number of RPM zones Maximum number of GRAFIK Eye per system 4,096 accessory controls per system 720 Technical Support: hwisupport@lutron.com 3.15
Page 26
Notes S Y STEM DESIGN www.lutron.com 3.16
Page 27
Local Controls FRONT ROOM EQUIPMENT Technical Support: hwisupport@lutron.com 4.1
Page 28
Rania® RF Local Lighting Controls LOCAL LIGHTING CONTROLS WALL DIMMER Rania RF local lighting controls, function like standard LOAD RATINGS wall and lamp dimmers, and can be controlled as part HRI-45D1-1x will dim single of the whole-house lighting control system. Local incandescent, magnetic low- lighting controls are useful in locations where single voltage or electronic low-voltage circuits of lighting need to be dimmed. Rania RF circuit up to 450 W/VA. dimmers have advanced features such as fade-on/fade- off, long fade-to-off, and rapid full-on. In addition, the local control may be programmed similar to a keypad button press with single and double tap functions, turning multiple lights on or off. Rania RF LAMP DIMMER local lighting controls install in single-pole, 2-way, LOAD RATINGS or 3-way applications. HRT-3LD-1x will dim single ACCESSORY CONTROLS incandescent/halogen or low- voltage lamp up to 30 0 W/VA. Remote dimmers (HI-RD) are used in combination with a Rania RF local lighting control to provide 2-way and 3-way control. As many as nine (9) HI-RD can be used with a single Rania RF dimmer. FINISHES AND COLOURS Rania RF local lighting controls are available in a variety of architectural colours and finishes. INSTALLATION NOTE See section 13. FRONT ROOM EQUIPMENT Recommended back box depth is 35 mm. Use either EBB-15-RD (round back box) or EBB-15-SQ (square back box, quantity 15). IMPORTANT NOTE: Regulations for products with radio frequency COMMUNICATION TO SYSTEM change from country to country. Therefore, The Rania RF dimmer and the Rania RF lamp dimmer HomeWorks® products with radio frequency communicate to the HomeWorks® system through a are not available in all countries. hybrid repeater interface. A hybrid repeater (model HomeWorks products with radio frequency HR-REP-868) must be connected to the system in have been developed around two different order to control the RF dimmers. frequencies–434 MHz and 868 MHz. You All RF dimmers must be located within 9 m of a should use the HomeWorks software to hybrid repeater. One processor can control up to select the appropriate frequency for the 64 Rania RF dimmers. See figure 1 on page 10.2. regulations of your country. Contact Lutron for further assistance. ® www.lutron.com 4.2
Page 29
Rania® RF Wall Dimmer MODEL # HRI-45D1-1F AND HRI-45D1-1I Rania RF dimmers function like standard wall dimmers, and can be controlled as part of the whole-house lighting control system. Rania RF wall dimmers have advanced features such as fade-on/fade-off, long fade- to-off, and rapid full-on. In addition, the local control may be programmed similar to a keypad button press with single and double tap functions, turning multiple lights on or off. Rania RF local lighting controls install in single-pole, 2-way, or 3-way applications. FINISHES AND COLOURS Rania RF wall dimmers are available in a variety of architectural colours and finishes. See section 13. DIMMING CONTROL LOAD RATINGS HRI-45D1-1X will dim single incandescent, magnetic raise or lower press button light levels to toggle low-voltage or electronic low-voltage circuit up to 450 W/VA. status LEDs COMMUNICATION TO SYSTEM provide feedback The Rania RF dimmer communicates to the HomeWorks® system through a hybrid repeater interface. A hybrid repeater (model HR-REP-868) must be connected to the system in order to control the RF dimmers. All RF dimmers must be located within 9 m of a hybrid repeater. One processor can control up to 64 Rania RF dimmers. See figure 1 on page 10.2. FRONT ROOM EQUIPMENT Technical Support: hwisupport@lutron.com 4.3
Page 30
Rania® RF Local Lighting Controls Rania RF local lighting controls Models HRI-45D1-1F-: 450 W dimming control with frameless faceplate. HRI-45D1-1I-: 450 W dimming control with framed insert faceplate HI-RD-F-, HI-RD-I-: remote dimmer. Input voltage 220-240 V 50 Hz Regulatory approvals CE Environment Ambient temperature: 0 °C to 40 °C (32 °F to 104 °F) Ambient humidity: 0-90% humidity, non-condensing. Indoor use only. Addressing Via the HomeWorks utility using unique device serial numbers. Units must be ® installed prior to addressing. Counts as 1 of 64 addresses on a HomeWorks RF dimmer link. The device may be addressed without removing it from the wall. ESD protection Meets or exceeds the IEC 61000-4-2 standard. Surge protection Meets or exceeds ANSI/IEEE standard c62.41. Diagnostics LEDs provide diagnostics for troubleshooting. Fail-safe operation If communication with the processor is interrupted, all Rania RF controls will still provide local control. Dimensions See figures 1, 2, 3 page 4.5. Mounting Controls mount in round or square backbox, 35 mm deep. FRONT ROOM EQUIPMENTGanging When multiple HomeWorks RF controls are located in a single wallbox, the control must be derated. See page 4.6. Accessory controls Use only Lutron® HomeWorks Rania remote dimmers (HI-RD); mechanical 2- or 3- way switches will not work. Up to 9 HomeWorks Rania remote dimmers may be used with one HomeWorks Rania dimmer. HRI-45D1-1x dimming control 1 Load types Incandescent, magnetic or electronic low-voltage, tungsten halogen. Note: You cannot mix magnetic and electronic low-voltage loads on the same control. Maximum load single-gang: 450 W/VA multiple gang: 350 W/VA Minimum load 50 W/VA Line-voltage wiring See figures 5, 6 and 8, pages 4.6 and 4.7. Standard single-pole, 2-way, and 3-way wiring. Frequency 868 MHz HI-RD • 2- or 3-way Remote Dimmer For use with HRI-45D1-1x Maximum load See local lighting control. Minimum load See local lighting control. Line-voltage wiring See figure 6, 7 and 8, page 4.7. Standard single-pole, 2-way, and 3-way wiring. (1) To reduce the risk of overheating and possibly damaging other equipment, do not install HRI-45D1-1x to control receptacles, motor-operated appliances, or fluorescent lighting. www.lutron.com 4.4
Page 31
Rania® RF Local Lighting Controls 86 mm 20.7 mm 86 mm 7.4 mm Figure 1 – front view dimensions Figure 2 – side view dimensions 60.3 mm 60.3 mm FRONT ROOM EQUIPMENT diameter 57.15 mm Figure 3 – back view dimensions Technical Support: hwisupport@lutron.com 4.5
Page 32
Rania® RF Local Lighting Controls When the Rania RF dimmer is installed in a multiple gang configuration, the maximum rating decreases to 350 W/VA. Figure 4 – multiple gang configurations Live 220-240 V Lighting load FRONT ROOM EQUIPMENT Dimmer Neutral Figure 5 – HRI-45D1-1x single-location wiring diagram Live 220-240 V~ 50 Hz Lighting Load Note: Dimmer can replace Dimmer Accessory Dimmer any switch in the circuit. Connect up to a total of 9 Accessory Dimmers. Neutral Figure 6 – HRI-45D1- two-location wiring diagram (typical in EU) www.lutron.com 4.6
Page 33
Rania® RF Local Lighting Controls Live 220-240 V Note: Dimmer can replace any switch in the Dimmer Accessory Dimmer circuit. Connect up to Lighting a total of 9 Accessory Neutral load Dimmers. Figure 7 – two-location wiring diagram (typical in UK) Live 220-240 V Lighting load Dimmer Accessory Dimmer Accessory Dimmer Note: Dimmer can replace any switch in the circuit. Connect up to a total of 9 Accessory Neutral Dimmers. Figure 8 – Multi-location installation: Dimmer line side (typical in EU) FRONT ROOM EQUIPMENT Live 220-240 V Dimmer Accessory Dimmer Accessory Dimmer Note: Lighting Dimmer can replace load any switch in the Neutral circuit. Connect up to a total of 9 Accessory Dimmers. Figure 9 – Multi-location installation: Dimmer line side (typical in UK) Technical Support: hwisupport@lutron.com 4.7
Page 34
Rania® RF Lamp Dimmers MODEL # HRT-3LD-1U AND HRT-3LD-1U Rania RF lamp dimmers allow table and floor lamps to be included in the HomeWorks® lighting control system. Each RF lamp dimmer controls one table or floor lamp. Simple to install, RF lamp dimmers are plugged into any standard wall outlet. Lamp dimmers can be controlled from any HomeWorks keypad in the home as well as from touch screens, universal remotes, and home automation controls. RF lamp dimmers include advanced features such as fade-on/fade-off, long fade-to-off, and rapid full-on. The local control may be programmed like a keypad button press with single and double tap functions. FINISHES AND COLOURS raise or lower RF Lamp dimmers are available in Arctic White (AW) light levels and MICA (MC). press button to toggle lights on and off DIMMING CONTROL LOAD RATINGS HRT-3LD-1x controls a single incandescent/halogen status LEDs provide light level feedback or low-voltage lamp up to 300 W/VA. FRONT ROOM EQUIPMENTCOMMUNICATION TO SYSTEM The Rania RF dimmer and the Rania RF lamp dimmer communicate to the HomeWorks system through a hybrid repeater interface. A hybrid repeater (model HR-REP-868) must be connected to the system in order to control the RF dimmers. See page 10.3. All RF dimmers must be located within 9 m of a hybrid repeater. One processor can control up to 64 RF Rania dimmers. www.lutron.com 4.8
Page 35
Rania RF Lamp Dimmers ® Models HRT-3LD-1U-: Lamp dimming control for UK plug. HRT-3LD-1E-: Lamp dimming control for European plug. Input Voltage 220-240 V 50 Hz Regulatory Approvals CE Load Types Incandescent, magnetic or electric low-voltage, tungsten halogen. Maximum Load 300 W/VA Minimum Load 10 W/VA Environment Ambient operating temperature: 0 °C to 40 °C (32 °F to 104 °F) Ambient operating humidity: 0-90% humidity, non-condensing. Indoor use only. Addressing Via the HomeWorks software, using unique device serial numbers. Units must be ® installed prior to addressing. Counts as 1 of the 64 dimmer addresses on the RF link. Diagnostics LEDs provide diagnostics for troubleshooting. ESD Protection Meets or exceeds the IEC 61000-4-2 standard. Surge Protection Meets or exceeds ANSI/IEEE standard c62.41. Fail-Safe Operation If communication with the processor is interrupted, all Rania RF controls will still provide local control. Frequency 868 MHz FRONT ROOM EQUIPMENT Cord length 2 m Diameter 70 mm Plug lamp dimmer into any standard UK wall socket. Diameter Cord length 2 m 70 mm Plug lamp dimmer into any standard EU wall socket. Figure 1 – Installation Figure 2 – Unit Dimensions Technical Support: hwisupport@lutron.com 4.9
Page 36
Maestro Local Lighting Controls ® LOCAL LIGHTING CONTROLS DIMMING CONTROL LOAD RATINGS Maestro local lighting controls function like standard dimmers and switches, but can be controlled as part of HWA-5E-CE and HNA-5E-CE the whole-house lighting control system. Local lighting dim a single incandescent or controls are useful in locations where single circuits of electronic low-voltage circuit lighting need to be dimmed or switched. Maestro up to 500 W/VA. dimmers have advanced features such as fade on/fade off, long fade to off, and rapid full on. In addition, the local control may be programmed similar to a keypad button press with single and double tap SWITCHING CONTROL functions, turning on or off multiple lights. LOAD RATINGS HomeWorks® Maestro local lighting controls install HWA-2ANS-CE and HNA-2ANS-CE in single-pole, 2-way, or 3-way applications. switches a single circuit of ACCESSORY CONTROLS any lighting load type up to 2 A. A neutral wire connection Remote dimmers (HA-RD) and remote switches (HA-RS) is required. are used in combination with a Maestro local lighting control to provide 2-way and 3-way control. As many as nine (9) HA-RD or HA-RS can be used with a single Maestro dimmer or switch. INSTALLATION NOTE FINISHES AND COLOURS Use 89 mm (3-1/2 inch) deep wallboxes for ease of installation. Lutron model 241218 may be used. Maestro local lighting controls are available in ® black (BL) and white (WH) matt plastic finishes. FRONT ROOM EQUIPMENTSee section 13. CONNECTION TO H48 DIMMER INTERFACE All Maestro local lighting controls must be connected GANGING MAESTRO CONTROLS to an H48 dimmer interface. A Dimmer Interface is available as a stand-alone component (model Maestro controls can be mounted together in a HWI-H48) or as an integral part of processors multi-gang wallbox. The load rating for each control H4P5-H48-CE, H4P5-H48-HRL-CE, H8P5-MI-H48-CE must be derated when ganging with other controls. and H8P5-H48-CE. Each Maestro local lighting control See page 4.14. communicates with a dimmer interface via a one pair 2 twisted shielded 0.5 mm (22 AWG) cable. www.lutron.com 4.10
Page 37
Maestro Local Lighting Controls ® All HomeWorks Maestro local lighting controls ® Model HWA-5E-CE: 500 W dimming control. HNA-5E-CE: 500 W dimming control (non-system). HWA-2ANS-CE: 2 A switching control with neutral wire. HNA-2ANS-CE: 2 A switching control with neutral wire (non-system). HA-RD: accessory control/remote dimmer. HA-RS: accessory control/remote switch. Input voltage 220-240 V 50/60 Hz Regulatory approvals CE, C-Tick Environment Ambient temperature: 0 °C to 40 °C (32 °F to 104 °F) Ambient humidity: 0-90% humidity, non-condensing. Indoor use only. 2 Low-voltage wire type One pair twisted shielded 0.5-1.0 mm (18-22 AWG) Class 2/PELV wiring. Low-voltage wiring Daisy-chain, star, T-tap, home run. Each Maestro bus may have a maximum 150 m configuration (500 feet) per wire run but may not exceed 305 m (1000 feet) total per bus. Maximum of eight devices per dimmer interface bus. Addressing Via the HomeWorks utility using unique device serial numbers. Units must be installed prior to addressing. Counts as 1 of 8 addresses on a Maestro bus. The device may be addressed without removing it from the wall. ESD protection Meets or exceeds the IEC 61000-4-2 standard. Surge protection Meets or exceeds ANSI/IEEE standard c62.41. Fail-safe operation If communication with the processor is interrupted, all Maestro controls will still provide local control. Dimensions See figure 1, page 4.13. Mounting Controls mount in standard US wallboxes. For easier installation, Lutron ® recommends using 89mm (3-1/2 inch) deep wallboxes. Lutron model 241218 may be used. FRONT ROOM EQUIPMENT Ganging When multiple Maestro controls are located in a single wallbox, the control must be derated. See page 4.14. If mounting one control above another, leave at least 11.4 cm (4-1/2 inch) vertical spacing between them. Accessory controls Use only Lutron Maestro remote dimmers or switches (HA-RD or HA-RS); mechanical 2- or 3-way switches will not work. Up to 9 Maestro remote dimmers or switches may be used with one Maestro dimmer or switch. Shipping weight 0.3 kg (0.6 pounds) Technical Support: hwisupport@lutron.com 4.11
Page 38
Maestro Local Lighting Controls ® HWA-5E and HNA-5E dimming control 1 Load types Incandescent, electronic low-voltage, tungsten halogen. Maximum load single-gang: 500 W/VA end gang: 450 W/VA middle gang: 400 W/VA Note: Mixed incandescent and electronic low-voltage loads reduces load capacity an additional 100 watts. Minimum load 50 W/VA Line-voltage wiring See figures 5 and 7, pages 4.14 and 4.5. Standard single-pole, 2-way, and 3-way wiring. HWA-2ANS-CE and HNA-2ANS-CE • 2A switching control with neutral wire 1 2 Load types Incandescent, magnetic low-voltage, electronic low-voltage, fluorescent with magnetic ballasts. Maximum load 2 A Minimum load 10 W/VA Line-voltage wiring See figures 6 and 8, page 4.15. Single-pole, 2-way, and 3-way wiring. A neutral wire connection is required. HA-RD • 2- or 3-way Remote Dimmer FRONT ROOM EQUIPMENTFor use with HWA-5E-CE, HNA-5E-CE Maximum load See local lighting control. Minimum load See local lighting control. Line-voltage wiring See figure 7, page 4.15. Standard single-pole, 2-way, and 3-way wiring. HA-RS • 2- or 3-way Remote Switch For use with HWA-2ANS-CE, HNA-2ANS-CE Maximum load See local lighting control. Minimum load See local lighting control. Line-voltage wiring See figure 8, page 4.15. Standard single-pole, 2-way, and 3-way wiring. (1) To reduce the risk of overheating and possibly damaging other equipment, do not install HWA-5E-CE or HNA-5E-CE to control receptacles, motor-operated appliances, fluorescent lighting, or magnetic low-voltage transformer loads. Do not install HWA-2ANS-CE or HNA-2ANS-CE to control receptacles or motor-operated appliances. (2) Because low-voltage transformers vary widely in efficiency, the input VA of each transformer should be measured directly. If this is not possible, use the maximum lamp wattage figures, which have a built-in safety margin. www.lutron.com 4.12
Page 39
Maestro Local Lighting Controls ® A Low-voltage wiring Power wiring B C D Wallbox mm inches A 119 4-11/16 B 75 2-15/16 C 7.6 5/16 D 34.8 1-3/8 Figure 1 – dimensions Figure 2 – wire installation Wallbox (Lutron model ® 241218 may be used) FRONT ROOM EQUIPMENT Control Wallplate adapter Wallplate Figure 3 – mounting and parts identification Technical Support: hwisupport@lutron.com 4.13
Page 40
Maestro Local Lighting Controls ® Minimum Maximum load load Control all cases single-gang end gang middle gang HWA-5E-CE 50 W/VA 500 W/VA 450 W/VA 400 W/VA HNA-5E-CE 50 W/VA 500 W/VA 450 W/VA 400 W/VA HWA-2ANS-CE 10 W/VA 2A 2A 2A HNA-2ANS-CE 10 W/VA 2A 2A 2A HA-RD n/a n/a n/a n/a HA-RS n/a n/a n/a n/a Table 1 – minimum and maximum load ratings END of gang FRONT ROOM EQUIPMENT Single gang MIDDLE of gang Figure 4 – ganging configuration and derating information Dimmer To HomeWorks® H48 dimmer interface or next HomeWorks Maestro® Class 2/PELV wiring (HWA- controls only) Live Lighting load 220-240 V 50 Hz Neutral Figure 5 – HWA-5E-CE and HNA-5E-CE single-location wiring diagram www.lutron.com 4.14
Page 41
Maestro Local Lighting Controls ® Switch To HomeWorks® H48 dimmer interface or next HomeWorks Maestro® Class 2/PELV wiring (HWA- controls only) Live Lighting load 220-240 V Neutral Figure 6 – HWA-2ANS-CE and HNA-2ANS-CE single-location with neutral wiring diagram 1 1 Dimmer To HomeWorks® H48 dimmer Remote Dimmer Remote Dimmer interface or next HomeWorks Maestro® Class 2/PELV wiring (HWA- controls only) Lighting Live load 220-240 V Neutral Figure 7 – HWA-5E-CE and HNA-5E-CE multi-location wiring diagram 1 1 2 To HomeWorks® H48 dimmer Remote switch Remote switch Switch interface or next HomeWorks Maestro® Class 2/PELV wiring (HWA- controls only) FRONT ROOM EQUIPMENT Lighting Live load 220-240 V Neutral Figure 8 – HWA-2ANS-CE and HNA-2ANS-CE multi-location with neutral wiring diagram 1 Up to nine Maestro remote dimmers or switches may be connected to the Maestro dimmer or switch. Total distance between all devices should not exceed 50 m (165 feet). 2 Switches must be connected on the lighting load side of a multi-location installation. Technical Support: hwisupport@lutron.com 4.15
Page 42
GRAFIK Eye Preset Local Lighting Controls ® GRAFIK Eye preset local lighting controls allow you to Fade easily create and recall multiple lighting scenes in a room. Up to 16 preset scenes can be stored in each GRAFIK Eye, making them ideal for home cinemas, living rooms, and dining rooms. GRAFIK Eye preset scenes can be easily adjusted at any time. GRAFIK Eye controls are available to dim or switch two, three, four, or six zones of lighting. Scenes CONNECTION TO PROCESSOR Each HomeWorks processor has three configurable ® Zones Built-in infrared receiver links each capable of controlling up to eight GRAFIK Eye control units or WPMs. This connection requires GRAFIK Eye preset lighting control two pair [one pair 1.0 mm2 (18 AWG), one pair 0.5 to 2 (GRX-3504-CE shown) 1.0 mm (18-22 AWG) twisted shielded] Class 2/PELV wire. Lutron wire model GRX-CBL-346S-500 may be ® used. The maximum cable length is 610 m (2,000 feet), and this link must be wired in a daisy-chain GRAFIK EYE CONTROL UNIT configuration. INSTALLATION NOTES ACCESSORY CONTROLS Use 89 mm (3-1/2 inch) deep wallboxes for ease of Handheld Infrared installation of GRAFIK Eye control units. (Lutron model Remote Control Transmitters 241400) GRX-IT, GRX-8IT (white only) FRONT ROOM EQUIPMENT Controls four or eight scenes plus master raise/lower and off. FINISHES AND COLOURS GRAFIK Eye preset local lighting controls are available in matt plastic finishes and metallic finishes. See section 13. www.lutron.com 4.16
Page 43
GRAFIK Eye Preset Local Lighting Controls ® Control Units Model GRX-3502-CE, GRX-3503-CE, GRX-3504-CE, GRX-3506-CE: allows scene and zone control from HomeWorks®. GRX-3102-CE, GRX-3103-CE, GRX-3104-CE, GRX-3106-CE: allows scene control only from HomeWorks. Input voltage 220-240 V 50/60 Hz Regulatory approvals CE, C-Tick Load types Incandescent, magnetic low-voltage, electronic low-voltage (requires Lutron ® low-voltage transformers), fluorescent non-dim, neon/cold cathode. The outputs are also compatible with Lutron Power Boosters and interfaces on in section 6 Maximum load (CE) See table on page 4.18. Minimum load 25 W/VA per zone. Environment Ambient temperature: 0 °C to 40 °C (32 °F to 104 °F) Ambient humidity: 0-90% humidity, non-condensing. Indoor use only. Cooling method Passive cooling. Line-voltage connections See figures 3 and 4, page 4.20. Low-voltage wire type Two pair [one pair 1.0 mm2 (18 AWG), one pair 0.5 to 1.0 mm2 (18-22 AWG) twisted shielded] Class 2/PELV wire. Lutron wire model GRX-CBL-346S-500 may be used. Low-voltage wiring Maximum of 610 m (2,000 feet) total. Must be wired in a daisy-chain configuration configuration. See figures 5 and 6, page 4.21. Low-voltage connections One 4-pin removable terminal block. Each of the four terminals will accept up to 2 two 1.0 mm (18 AWG) wires. Do not connect terminal 2 on processor communication link connector or between GRX units. FRONT ROOM EQUIPMENT Addressing Via 7-segment display. Use 1 of 8 addresses on a GRAFIK Eye link. ESD protection Meets or exceeds the IEC 61000-4-2 standard. Surge protection Meets or exceeds ANSI/IEEE standard c62.41. Air gap Provided when all circuits are off. Power-failure memory Non-volatile RAM. Fail-safe operation If communication with the processor is interrupted, all GRAFIK Eye controls will still provide local control. Dimensions See figure 1, page 4.19. Mounting (CE) All CE-compliant units mount in 4-gang US wallbox 7.0 cm (2-3/4 inches) deep minimum, 8.9 cm (3-1/5 inch) deep recommended for ease of wiring. Lutron model 241400 may be used. Shipping weight 0.9 kg (2.0 pounds) Technical Support: hwisupport@lutron.com 4.17
Need assistance or looking to source this item?