Page 1
GXI-3000 Preset Dimming Controls 3691017b 1 08.12.16 GXI-3000 Control Unit Description Cover (shown open) • Provides pushbutton recall of four preset lighting scenes, plus Off. • Allows setup of lighting scenes using buttons on the Control Unit. • Controls virtually any light source (LED, incandescant, etc.) without an interface. • Provides lockout options to prevent accidental changes. • Includes built-in infrared receiver for operation with an optional remote control. Models available to: • Accept 230 V~ (CE) input power. • Control four zones of lighting. Base GXI-3100 Control Unit allows Zone Infrared Receiver Scene Selection Buttons setup of lighting scenes using GXI-3000 Control Unit buttons on the Control Unit. GXI-3500 Control Unit allows setup of lighting scenes using a PC, including setting lighting levels in 1% increments. SSPPecification Submittalecification Submittal PagePage 1 Job Name:Job Name: Model Numbers:Model Numbers: Job Number:Job Number:
Page 2
GXI-3000 Preset Dimming Controls 3691017b 2 08.12.16 Specifications Input Power • Provides air gap isolation when the Off scene is • 230 V~ (CE) 50 Hz selected. • Lightning Strike Protection: • 10-year power failure memory automatically restores Can withstand voltage surges of up to 6000 V~ lighting to levels prior to power interruption. and current surges up to 3000 A. • Faceplate snaps on with no visible means of Sources attachment. Controls the following lighting sources with a System Communications and Capacities smooth, continuous Square Law dimming curve • Low-voltage type PELV wiring connects Control or on a full conduction non-dim basis: Units, Wallstations, and Control Interfaces. • LEDs • Up to 8 Control Units may be linked to control up to • Incandescent 32 zones. • Electronic Low Voltage • Up to 16 total Wallstations and Control Interfaces • Magnetic Low Voltage may be added for a total of 24 control points. • Fluorescent • Neon and Cold Cathode Environment Load Types • 0-40°C. Relative humidity less than 90% non-condensing. • Leading/Trailing-edge dimming • 0-10 V- • DALIR (broadcast only) • Switching (non-dimming) Preset Controls • 4 preset lighting scenes and off are accessible from the Control Unit front panel. • 12 additional scenes are stored in the Control Unit. These scenes are accessible via Wallstations and/or Control Interfaces. • Light levels fade smoothly between scenes. Fade time can be set differently for each scene, between 0-59 sec. or 1-60 min. Fade time from Off is capped at 5 sec. Key Design Features • Meets IEC 801-2. Tested to withstand 15 kV electrostatic discharge without damage or memory loss. • Provides over-current and short-circuit protection. • Provides capability to trim High End and Low End. • Manual or automatic selection between leading edge or trailing edge dimming for low voltage transformers. SSPPecification Submittalecification Submittal PagePage 2 Job Name:Job Name: Model Numbers:Model Numbers: Job Number:Job Number:
Page 3
GXI-3000 Preset Dimming Controls 3691017b 3 08.12.16 How to Build a Model Number Cover Options Color Options G X I - 3 1 0 4 - T - C E - W H Architectural Matte Finishes Opaque A Standard – Ship in 48 hours Cover and Base will match. Prefix Translucent Black T Cover Option: A or T White WH Set-Up Black Cover and choice of Color Ivory IV Method base color. Option Beige BE Gray GR Input Number Brown BR Also available: Voltage of Zones Black BL - Custom controls Cover - Color matching Designer Gloss Finishes Option - Engraving Ship in 4 to 6 weeks Cover Option: A only Prefix: These options ship in 4 to 6 White GWH GXI for GRAFIK Integrale 3000 Series weeks Light Almond GLA Almond GAL Control Units Set-Up Method: Ivory GIV Satin Color Matte Finishes 1 for standard setup via front panel Cover Option: A or T 5 for PC setup Hot HT Ochre OC Number of Zones: Terracotta TC 4 Desert Stone DS Stone ST Cover Option: Limestone LS A for Opaque Blue Mist BT T for Translucent Black Midnight MN Taupe TP Input Voltage Biscuit BI Eggshell ES CE for 230 V~ (CE) Snow SW Color Option: Architectural Metal Finishes Cover Option: T only Bright Brass BB See Color Options list Bright Chrome BC Model Number Satin Brass SB Satin Chrome SC 230 V~ (CE) Input Power Satin Nickel SN Antique Brass QB Antique Bronze QZ Zone Capacity Bright Nickel BN Number of Model Number Unit Dimmed/ Low-voltage Anodized Aluminum Finishes Zones Capacity Switched control Cover Option: T only Live OUtput output Clear CLA Black BLA Up to 20 LED Brass BRA GXI-3104-_-CE-__ 2300 W/VA 800 W/VA 4 Drivers / Ballasts Bronze BZA Up to 20 LED GXI-3504-_-CE-__ 2300 W/VA 800 W/VA 4 Drivers / Ballasts SSPPecification Submittalecification Submittal PagePage 3 Job Name:Job Name: Model Numbers:Model Numbers: Job Number:Job Number:
Page 4
GXI-3000 Preset Dimming Controls 3691017b 4 08.12.16 Dimensions and Mounting Dimensions shown as: in (mm) 3 (76) 8 (200) 8 (208) 5 (138) 4 (95) 3 (84) 9 (227) Side View Backbox Front Views 0.3 (8) Lutron P/N 241-400 2 (49) 4.5 (116) 3 (73) Lutron P/N 241-691 (old-work backbox) SSPPecification Submittalecification Submittal PagePage 4 Job Name:Job Name: Model Numbers:Model Numbers: Job Number:Job Number:
Page 5
GXI-3000 Preset Dimming Controls 3691017b 5 08.12.16 230 V~ (CE) Mains Voltage Wiring Pull power wiring from distribution panel and to light fixtures. Each Consult Lutron for: 2 line voltage terminal can accept up to two 12 AWG (2.5 mm ) wires. • Non-dim relay wiring. For phase-to-neutral wiring, connect one phase to Live and the other • Load side emergency transfer phase to Neutral. When wired phase-to-phase, the air gap does not wiring. break both phases while the Control Unit is Off: the MCB(s) must be turned off when servicing the Control Unit or associated loads. Load 1 Hot/Live Hot/Live Distribution Panel Neutral Neutral D Load 2 Earth/ DL/SL 1 Ballast Control Outputs D 0-10 V- / DALIR control outputs Ground DL/SL 2 2 Zone Zone Zone Zone DL/SL 3 (2) 2.5 mm Hot/Live DL/SL 4 1 2 3 4 (2) PELV ONLY Neutral } } } } 2 1 2 3 4 - + - + - + - + 2.5 mm Load 3 Rear View of GXI-3104 Control Unit 2 2 - and DaliR control Wiring (2) 2.5 mm 0-10 V (2) 1.0 mm + Load 4 - Driver - Low-Voltage PELV Wiring • System communications use low-voltage PELV (Class 2) wiring. • Wiring must be daisy-chained. • Wiring must run separately from line (mains) voltage. PELV (Class 2) wiring link requires: 2 Two 12 AWG (2.5 mm ) conductors for control power. 2 One twisted, shielded pair of 18 AWG(0.75 mm ) for data link. Total length of Control Link may be up to 2000 ft (610 m). 1 Approved low-voltage cable is available from Lutron , Belden, and Liberty. 2 These are approved with 22 AWG (0.25 mm ) data link wires. Control Interface Wallstations Power Control Unit Supply External 12 V- Power Supply is required to power more than three 1 GRX-CBL-346S PELV (Class 2) wiring cable is available from Lutron and contains: Wallstations and/or Control Interfaces 2 - Two 12 AWG (2.5 mm ) conductors for control power. from a single Control Unit. 2 - One twisted, shielded pair of 22 AWG (0.25 mm ) for data link. SSPPecification Submittalecification Submittal PagePage 5 Job Name:Job Name: Model Numbers:Model Numbers: Job Number:Job Number:
Page 6
GXI-3000 Preset Dimming Controls 3691017b 6 08.12.16 PELV Terminal Connections 2 • Each PELV terminal accepts up to two 1.0 mm wires. • Daisy chain the terminal 1, 3, and 4 connections to all Control Hot/Live Neutral Units, Wallstations, and Control Interfaces. DL/SL 1 Ballast Control Outputs DL/SL 2 Zone Zone Zone Zone • Each Control Unit has its own power supply. Terminate the DL/SL 3 DL/SL 4 1 2 3 4 Neutral PELV ONLY terminal 2 connection (12 V- power) so that each Control } } } } Neutral 1234 1 2 3 4 +-+- +-+- Unit supplies power to a maximum of three Wallstations. Each Wallstation should receive power from only one Control Unit. • Make all connections in the Control Unit’s wallbox. Remote connections must be in a switchbox or junction box with a maximum wire length of 8 ft (2.5 m) from the link to the connected unit. • Do not allow PELV wires to contact line/mains wires. Rear View of GXI-3000 Control Unit Rear View of GXI-3000 Control Unit a3 PELV ONLY 1234 a1 PELV ONLY 1234 5 Lutron Cable, GRX-CBL-346S 4 3 2 1 A3 powers Wallstations A2 and A3 2, 3, and 4 – no terminal 6 have their own No. 2 connection power supplies – between Wallstations no terminal No. 2 2 4 1 4 and 5 3 connection 2 4 1 3 4 3 2 2 1 4 1 3 4 2 3 1 7 2 1 3 A1 powers 1 only – 4 3 terminal No. 2 connection 4 2 3 1 terminates at Wallstation 1 2 1 4 3 2 1 A4 powers Wallstations 5, 6, and 7 – no terminal 4 No. 2 connection between 4321 Wallstations 4 and 5 4 PELV ONLY 3 a2 2 1 4 3 2 1 Rear View of GXI-3000 Control Unit 4321 PELV ONLY Note: A4 • Up to 8 GXI-3000 Series Control Units and 16 Wallstations/Control Interfaces may be daisy-chained together in one system. Rear View of GXI-3000 Control Unit • PELV/Class 2 cable is available from Lutron - order GRX-CBL-346S. SSPPecification Submittalecification Submittal PagePage 6 Job Name:Job Name: Model Numbers:Model Numbers: Job Number:Job Number: