This document could not be shown here. Open the PDF.
Text of this document9 pages · 810 words
Page 1
LSM-HZ-FP 6 HORIZONTAL FIXED PANEL LIFT SYSTEM TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
LSM-HZ-FP 6 HORIZONTAL FIXED PANEL LIFT SYSTEM SPECIFICATION MEASUREMENTS Maximum Screen Width 1490mm ( ) 58 11/16" Maximum Weight Capacity 50Kg (110lb) Maximum Weight Capacity (Marine) 30Kg (66lb) Internal Cabinet Width 1910mm (75 3/16") Decibel Rating 52 dB Packaging Dimensions 2010 x 890 x 270mm (79 1/8" x 35 1/16" x 10 5/8") Shipping Weight 55Kg (121b) Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption 250 - 500W Power Consumption Standby 3W Mounting Patterns Supported VESA 400, 300, 200 W x 400, 300, 200 H Control Options IR Remote, RS232, Contact Closure, RF Available Product Options / Features Specific B&O and Loewe mounts / adapters, Custom RAL paint finishes Package Contents Mechanism, IR remote control Marine Suitable Yes (Indoor Marine Only) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
LSM-HZ-FP 6 HORIZONTAL FIXED PANEL LIFT SYSTEM MECHANISM OUT OF CABINET 58 11/16" 1490 Max Screen Width D 5 1/16" SECTION B-B 1 13/16" 129 46 DETAIL D Back of Cabinet to Back of Aperture 13/16" 1/8" 20 3 Max Minimum Perimeter Shadow Gap Internal Cabinet Height = Screen Height + 100 [3 15/16"] Minimum Height = 950 [37 3/8"] C B B 75 3/16" 1910 C Internal Cabinet Width SECTION C-C TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
LSM-HZ-FP 6 HORIZONTAL FIXED PANEL LIFT SYSTEM Shown with tapered fixed panel in square Cabinet Aperture to improve fit 58 11/16" MECHANISM IN CABINET 1490 Max Screen Width F SECTION E-E DETAIL F 13/16" Aperture Width = 20 Screen Depth + 95 [3 3/4"] 75 3/16" Max 1910 (Minimum 131 [5 3/16"]) Internal Cabinet Width
E E Aperture Height= Screen Height +46mm [1 13/16"] 657 495 25 7/8" 19 1/2" Minimum 676mm [26 5/8"]
15 3/4" 400 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
LSM-HZ-FP 6 HORIZONTAL FIXED PANEL LIFT SYSTEM MECHANISM INSTALLATION OVERVIEW Front of cabinet must be The LSM is fixed to the back of the removable to fit mechanism mounting surface with appropriate fixings Cable tie saddles fix cables to horizontal beam Base panel Screen Mount is removable for ease of install Cover conceals cables from viewer Adjustable Rails The fixed panel is secured to the mechanism using appropriate fixings TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 5 FUTUREAUTOMATION
Page 6
LSM-HZ-FP 6 HORIZONTAL FIXED PANEL LIFT SYSTEM fixed panel NOTE: A tapered creates a good fit fixed panel in the Cabinet Aperture and helps the BASE PANEL AND FIXED PANEL DETAILS locate within the cabinet. 13/16" 20 1 5/8" BASE PANEL 42 19 7/8" 505 =Cabinet Aperture Width -6mm [1/4"] (Minimum 115mm [4 1/2"]) = Cabinet Aperture Height -6mm [1/4"] FIXED PANEL =Cabinet Aperture Width =Cabinet Aperture Width -2mm [1/16"] -6mm [1/4"] = Cabinet Aperture Height -2mm [1/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 6 FUTUREAUTOMATION
Page 7
LSM-HZ-FP 6 HORIZONTAL FIXED PANEL LIFT SYSTEM SCREEN MOUNT ADJUSTABILITY A standard adjustable height VESA 400 mount is included. This is also compatible with VESA 300 and 200 mounting patterns Separate VESA 300 and 200 mounts are available. 16 3/4" 425 Highest Bolt Location C L V400 V300 C L 16 15/16" 430 Lowest Bolt Location V200 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 7 FUTUREAUTOMATION
Page 8
LSM-HZ-FP 6 HORIZONTAL FIXED PANEL LIFT SYSTEM 1 1/2" 38 Maximum Possible Depth of Conduit CABLE ROUTING The LSM-HZ comes with cable tie saddles on the outside of the two horizontal beams. A cable cover is supplied to conceal these cables when in use. Cables must be routed carefully to prevent any interference with the LSM beam as it To Mains Power operates. Screen and Mechanism cables should be routed to a control box outside of the cabinet via an opening in the back of the cabinet or a conduit leading to the bottom. SCREEN CABLES MECHANISM CABLES POWER CABLE AI AI TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 8 FUTUREAUTOMATION
Page 9
LSM-HZ-FP 6 HORIZONTAL FIXED PANEL LIFT SYSTEM OVERALL MECHANISM DIMENSIONS MECHANISM OUT POSITION 75 3/16" 1910
795 495 19 1/2" 31 5/16"
2 1/8" 6 5/8" 54 169 75 1/8" 1908 136 1/4" 3460 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 9 FUTUREAUTOMATION
Need assistance or looking to source this item?