Page 1

LSM-HZ-FP 5 HORIZONTAL FIXED PANEL LIFT SYSTEM TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

LSM-HZ-FP 5 HORIZONTAL FIXED PANEL LIFT SYSTEM SPECIFICATION MEASUREMENTS Maximum Screen Width 1265mm (49 13/16") Maximum Weight Capacity 50Kg (110lb) Maximum Weight Capacity (Marine) 30Kg (66lb) Internal Cabinet Width 1690mm (66 9/16") Decibel Rating 52 dB Packaging Dimensions 1790 x 890 x 270mm (70 1/2" x 35 1/16" x 10 5/8") Shipping Weight 51Kg (112lb) Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption 250 - 500W Power Consumption Standby 3W Mounting Patterns Supported VESA 400, 300, 200 W x 400, 300, 200 H Control Options IR Remote, RS232, Contact Closure, RF Available Product Options / Features Specific B&O and Loewe mounts / adapters, Custom RAL paint finishes Package Contents Mechanism, IR remote control Marine Suitable Yes (Indoor Marine Only) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

LSM-HZ-FP 5 HORIZONTAL FIXED PANEL LIFT SYSTEM MECHANISM OUT OF CABINET 49 13/16" 1265 Max Screen Width D 1 13/16" 5 1/16" SECTION B-B 46 129 DETAIL D Back of Cabinet to Back of Aperture Internal Cabinet Height = Screen Height + 100 [3 15/16"] 1/8" 13/16" Minimum Height = 950 [37 3/8"] 3 20 Minimum Perimeter Shadow Gap Max C B B 66 9/16" C 1690 Internal Cabinet Width SECTION C-C TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

LSM-HZ-FP 5 HORIZONTAL FIXED PANEL LIFT SYSTEM Shown with tapered fixed panel in square cabinet aperture to improve fit. 49 13/16" MECHANISM IN CABINET 1265 Max Screen Width F SECTION E-E 13/16" DETAIL F 20 66 9/16" Aperture Width = Max 1690 Screen Depth + 95 [3 3/4"] Internal Cabinet Width (Minimum 131 [5 3/16"])

Aperture Height= Screen Height +46mm [1 13/16"] 26" 795 660 495

19 1/2" Minimum 676mm [26 5/8"] 31 5/16"

15 15/16" 405 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 4 FUTUREAUTOMATION

Page 5

LSM-HZ-FP 5 HORIZONTAL FIXED PANEL LIFT SYSTEM MECHANISM INSTALLATION OVERVIEW Front of cabinet must be The LSM is fixed to the back of the removable to fit mechanism mounting surface with appropriate fixings Cable tie saddles fix cables to horizontal beam Base panel Screen Mount is removable for ease of install Cover conceals cables from viewer Adjustable Rails The fixed panel is secured to the mechanism using appropriate fixings TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 5 FUTUREAUTOMATION

Page 6

LSM-HZ-FP 5 HORIZONTAL FIXED PANEL LIFT SYSTEM fixed panel NOTE: A tapered creates a good fit fixed panel in the Cabinet Aperture and helps the locate within the cabinet. BASE PANEL AND FIXED PANEL DETAILS 13/16" 20 1 5/8" 42 BASE PANEL 19 7/8" 505 =Cabinet Aperture Width -6mm [1/4"] (Minimum 115mm [4 1/2"]) = Cabinet Aperture Height -6mm [1/4"] FIXED PANEL =Cabinet Aperture Width =Cabinet Aperture Width -6mm [1/4"] -2mm [1/16"] = Cabinet Aperture Height -2mm [1/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 6 FUTUREAUTOMATION

Page 7

LSM-HZ-FP 5 HORIZONTAL FIXED PANEL LIFT SYSTEM SCREEN MOUNT ADJUSTABILITY A standard adjustable height VESA 400 mount is included. This is also compatible with VESA 300 and 200 mounting patterns Separate VESA 300 and 200 mounts are available. 14 1/4" 363 Highest Bolt Location C L V400 V300 C L 14 7/16" 368 Lowest Bolt Location V200 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 7 FUTUREAUTOMATION

Page 8

LSM-HZ-FP 5 HORIZONTAL FIXED PANEL LIFT SYSTEM 1 1/2" 38 Maximum Possible Depth of Conduit CABLE ROUTING The LSM-HZ comes with cable tie saddles on the outside of the two horizontal beams. A cable cover is supplied to conceal these cables when in use. Cables must be routed carefully to prevent any interference with the LSM beam as it To Mains Power operates. Screen and Mechanism cables should be routed to a control box outside of the cabinet via an opening in the back of the cabinet or a conduit leading to the bottom. SCREEN CABLES MECHANISM CABLES POWER CABLE AI AI TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 8 FUTUREAUTOMATION

Page 9

LSM-HZ-FP 5 HORIZONTAL FIXED PANEL LIFT SYSTEM OVERALL MECHANISM DIMENSIONS MECHANISM OUT POSITION 66 9/16" 1690

495 795 19 1/2" 31 5/16"

6 5/8" 169 2 1/16" 53 66 7/16" 1688 118 11/16" 3015 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 9 FUTUREAUTOMATION