This document could not be shown here. Open the PDF.
Text of this document6 pages · 1,677 words
Page 1
QS System QSE-CI-NWK-E Control Interface 369373h 1 04.23.26 QSE-CI-NWK-E Control Interface The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices can control and / or monitor a QS system. Features • E asily integrate with touchscreens, PCs, A / V systems, or other digital systems and devices • Control and monitor GRAFIK Eye QS, Sivoia QS, Energi Savr Node, and other products on the wired QS link • Monitor lighting scenes, levels, shade positions and more. For a full list of commands see Integration Protocol document (P/N 040249) at www.lutron.com • Up to 10 QSE-CI-NWK-E control interfaces are allowed per QS link • The QSE-CI-NWK-E is compatible with Athena, Quantum, QS standalone, and HomeWorks systems. For a complete list of compatible components see the Lutron Integration Protocol document (P/N 040249) at www.lutron.com • BAA-compliant model number available (UQSE-CI-NWK-E)* * For a complete list of BAA/TAA compliant products, please visit our website at www.lutron.com/BAA 1 R SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 2
QS System QSE-CI-NWK-E Control Interface 369373h 2 04.23.26 Specifications Regulatory Approvals Requirements • RoHS Compliant • QS Link Power Supply, such as a: • CE Marked – GRAFIK Eye QS • NOM – QS Link power supply, such as the QSPS-P1-1-50 • cULus – Energi Savr Node QS • QS Communication Link - SELV / PELV / NEC Class 2 Power ® (see QS Link Wire Sizes table) • SELV / PELV / NEC® Class 2 • Operating voltage: 24 – 36 V- 65 mA Protocol QS Link Limits • I ntegration Protocol document (P/N 040249) at www.lutron.com • T he QS wired communications link is limited to 1 2 3 4 5 6 7 8 100 devices and 100 zones. Each QSE-CI-NWK-E RS232 Connection 9600 control interface counts as 1 device and 0 zones • Standard 9-pin female serial connector on interface • Each QSE-CI-NWK-E control interface consumes 1 2 3 4 5 6 7 8 • 50 ft (15 m) maximum serial cable length 2 Power Draw Units (PDU) on the QS link. Refer 19200 to the QS Link Power Draw Units Specification • Dip switches are set at factory, all Off • Dip switches are used to set RS232 baud rate: 1 2 3 4 5 6 7 8 Submittal (P/N 369405) at www.lutron.com for 1 2 3 4 5 6 7 8 9600 more information 38400 DIP Switch Settings for RS232 Baud Rate • The maximum wiring length for the QS link is 1 2 3 4 5 6 7 8 2000 ft (610 m) 1 2 3 4 5 6 7 8 115200 115200 (default) 19200 Environment 1 2 3 4 5 6 7 8 • 32 °F to 104 °F (0 °C to 40 °C) 1 2 3 4 5 6 7 8 9600 38400 • Relative humidity less than 90% non-condensing 38400 • Indoor use only 1 2 3 4 5 6 7 8 • Unit generates heat, maximum 8 BTU / hr 1 2 3 4 5 6 7 8 19200 19200 115200 Integration Features 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9600 • Monitoring: Current scene, zone level, button 9600 38400 presses, shade group levels 1 2 3 4 5 6 7 8 • Control: Scene selection, scene lockout, zone 1 2 3 4 5 6 7 8 Ethernet Connection 115200 lockout, sequencing, zone raise / lower, master 19200 raise / lower, set shade group level, simulate • S tandard CAT5 (or better) cable, 328 ft (100 m) maximum, connects the QSE-CI-NWK-E interface button press / release 1 2 3 4 5 6 7 8 to a PC or other Ethernet source • F or the full list of features and commands, please 38400 refer to the Integration Protocol document • Supports MDI / MDIX auto-crossover (no crossover cable needed) (P/N 040249) at www.lutron.com 1 2 3 4 5 6 7 8 115200 • Auto-negotiation of 10 or 100 Mbps speed and full- Compatible Components or half-duplex operation • Default IP address is 192.168.250.1. Can be changed • Compatible with most QS devices. For a using the Lutron Device IP tool complete list of compatible components see Note: Either the RS232 or the Ethernet can be used, Integration Protocol document (P/N 040249) at but not both www.lutron.com 2 R SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 3
QS System QSE-CI-NWK-E Control Interface 369373h 3 04.23.26 Dimensions Dimensions are in inches (mm) 2.5 Mounting holes (63) Terminal blocks LEDs and addressing on this side switches on this side 3.75 4.25 Mounting Hole Detail (95) (108) 0.1875 (5) dia. 0.3125 (9) dia. 5.25 0.1875 (134) (5) dia. 0.25 (6) 1.0 #6 or #8 (M3 or M4) (27) screw recommended Mounting Options Mount where terminal blocks, switches, and LEDs Mounting Methods are accessible. Strip 3/8 in (10 mm) of insulation from wires. Each data link terminal will accept up 1 2 2 to two 18 AWG (1.0 mm ) wires. Connect wiring as shown on the Wiring page. LED 1 lights continuously (Power) and LED 7 blinks rapidly (Data Link RX) when the SELV / PELV / NEC® Class 2 Data Link is installed correctly. LUT-19AV-1U Choose from the following mounting methods: 1 Direct Wall Mounting Mount the control interface directly on a wall, as Wall 3 shown in Mounting Methods at right, using 2.50 screws (not included). When mounting, provide sufÏcient space for connecting cables. Control Interface 2 Rack Mounting 3.75 4.26 Place the unit in the LUT-19AV-1U AV rack using screws provided with the unit. The LUT-19AV-1U LUT-5x10-ENC will hold up to four units. 3 Enclosed Wall Mounting 5.26 If conduit is desired for wiring, use the 1.06 LUT-5x10-ENC to mount one unit. 3 R SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 4
QS System QSE-CI-NWK-E Control Interface 369373h 4 04.23.26 Terminal Locations Ethernet Link Female 9-pin QS Link to (to PC or AV RS232 Link other wired Equipment) (to PC or AV QS system Equipment) Devices LED and DIP Switch Locations 1 2 3 4 5 6 7 DIP Switches LED 1: Power LED 2: Ethernet Activity LED 3: Unused LED 4: RS232 Link Tx LED 5: RS232 Link Rx LED 6: QS Link Tx LED 7: QS Link Rx 4 R SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 5
QS System QSE-CI-NWK-E Control Interface 369373h 5 04.23.26 Wiring RS232 Link Ethernet Link Wiring • S tandard 9-pin serial connector plugs into RS232 • Standard CAT5 cable connects QSE-CI-NWK-E equipment, and to QSE-CI-NWK-E Interface to PC, router, or other Ethernet source • Must be 50 ft (15 m) or less • No crossover cable needed • Must be 328 ft (100 m) or less RS232 Signals • Ethernet network and cable provided by others Signals Pin on 9-Pin Cable Com 5 TxD 3 RxD 2 Ethernet Link: CAT5 Cable: 328 ft (100 m) max. RS232 Cable 50 ft (15 m) max. COM RS232 Link TxD to PC or AV RxD Equipment Rear View of GRAFIK Eye QS Control Unit QS Link 4321 12 ABC 1234 123456LN To additional QS devices QS Link: 1: Common 2: V+ 3: MUX 4: MUX See next page. Do not connect Pin 2 if using external power supply. 5 R SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 6
QS System QSE-CI-NWK-E Control Interface 369373h 6 04.23.26 Wiring (continued): QS Link Wiring Methods (choose one) • System communication uses SELV / PELV / NEC® • D o not allow SELV / PELV / NEC® Class 2 wires to Class 2 wiring. Follow all local and national electrical contact live / mains wire codes for installation • Typical Wire Sizes: See QS Link Wire Sizes table • Each terminal accepts up to two 18 AWG (1.0 mm²) • C onnect the terminal 1, 3, and 4 connections to wires or one 12 AWG (4.0 mm²) wire all control units, wallstations, and control interfaces • Total length of control link must not exceed in the QS system. For terminal 2 connectivity, 2000 ft (610 m) see below Powered by GRAFIK Eye QS Control Unit 12 Rear View of GRAFIK Eye QS ABC Control Unit 1234 Do not use 123456LN 4321 external Data Link: power supply 4: MUX if connecting 3: MUX QS Pin 2 See QS Link Link Wire Sizes table To additional SELV / PELV / NEC Class 2 Power wiring: wallstations / control interfaces 2: V+ ® 1: Common See QS Link Wire Sizes table Powered by a QS Link Power Supply* QS Link 1: Common QS (1) twisted pair 2: V+ Link 22 AWG 3: MUX 4321 2 4: MUX (0.5 mm ) To additional (1) 18 AWG wallstations / control 2 interfaces (1.0 mm ) Common Lutron Cable See QS Link Wire Sizes table PDU supplying device Do not use external power GRAFIK Eye QS QS Power Supply* supply if connecting Pin 2 Control Unit shown * Note: For details regarding powering from the QS Link, please refer to the QS Power Draw Units Specification Submittal (P/N 369405) at www.lutron.com QS Link Wire Sizes (check compatibility in your area) QS Link Wiring Length Wire Gauge Lutron Cable Part Number Power (terminals 1 and 2) 2 GRX-CBL-346S (non-plenum) < 500 ft (153 m) 1 pair 18 AWG (1.0 mm ) Data (terminals 3 and 4) GRX-PCBL-346S (plenum) 2 1 twisted, shielded pair 22 AWG (0.5 mm ) Power (terminals 1 and 2) 500 ft–2000 ft 2 GRX-CBL-46L (non-plenum) 1 pair 12 AWG (4.0 mm ) (153 m–610 m) Data (terminals 3 and 4) GRX-PCBL-46L (plenum) 2 1 twisted, shielded pair 22 AWG (0.5 mm ) Lutron, Athena, HomeWorks, GRAFIK Eye, Sivoia, Energi Savr Node, Quantum, and any related trade dress and logos are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. All other product names, logos, and brands are property of their respective owners. 6 R SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Need assistance or looking to source this item?