This document could not be shown here. Open the PDF.
Text of this document8 pages · 2,062 words
Page 1
Radio Powr Savr Wireless Wall-Mount Occupancy and Vacancy Sensors 369481m 1 04.14.26 Radio Powr Savr Wireless Occupancy / Vacancy Wall-Mount Sensor Lutron Radio Powr Savr wall-mounted occupancy and vacancy sensors are wireless, battery-powered, passive infrared (PIR) sensors that automatically control lights via RF communication to compatible dimming or switching devices. These sensors detect the heat from people moving within an area to determine when the space is occupied. The sensors then wirelessly transmit the appropriate commands to the associated dimming or switching devices to turn the lights on or off automatically. They combine both convenience and exceptional energy savings along with ease of installation. Features • Wireless occupancy / vacancy sensor has 2 settings available: Auto-On / Auto-Off, and Manual-On / Auto-Off • Vacancy model meets CA Title 24 requirements • Passive infrared motion detection with exclusive Lutron XCT Technology for fine motion detection • 180° field of view model: 2 2 – Minor motion = 1500 ft (139.4 m ) 2 2 Models Available – Major motion = 3000 ft (278.7 m ) • 90° field of view model: • LRF - LB-P-WH 2 2 Coverage Type – Minor motion = 1225 ft (113.8 m ) 2 2 Sensor Type – Major motion = 2500 ft (232.3 m ) • Hallway model with long, narrow field of view: Frequency / Channel Code – Major motion = coverage of up to 150 ft (45.7 m) Example: • Simple and intuitive adjustments available for Timeout, LRF2-VHLB-P-WH Activity, and Auto-On settings (434 MHz White Hallway Vacancy Sensor) • Accessible test buttons make setup easy Frequency / Channel Code • Lens illuminates during test mode to verify ideal locations 2 = 431.0 – 437.0 MHz* • Multiple sensors can be added for extended coverage; 3 = 868.125 – 869.850 MHz refer to product specification submittal of receiving device 4 = 868.125 – 868.475 MHz to determine system limits 5 = 865.5 – 866.5 MHz • 10-year battery life design 7 = 433.05 – 434.79 MHz • RoHS compliant Compatible RF Devices Sensor Type • For use with Lutron products only O = Occupancy / Vacancy (Auto-On / Auto-Off) • Supports simultaneous association with multiple Lutron V = Vacancy (Manual-On / Auto-Off)** Clear Connect devices and / or systems* Coverage Type * Contact Lutron Customer Service at www.lutron.com/support for H = Hallway frequency / channel code compatibility with your particular geographic K = 90° Corner-Mount region, and for integrating with other Lutron lighting and shading W = 180° Wall-Mount products. * BAA compliant models available for LRF2 configurations. Add a “U” prefix to your chosen model number. Example: ULRF2-OWLB-P. For a complete list of BAA/TAA compliant products please visit our website at Lutron.com/BAA and select “Download BAA Product List”. SPECIFICATION SUBMITTAL ** Vacancy sensor type for LRF2 models only Page 1 ® Job Name: Model Numbers: Job Number:
Page 2
Radio Powr Savr Wireless Wall-Mount Occupancy and Vacancy Sensors 369481m 2 04.14.26 Specifications Regulatory RF Range • Lutron Quality Systems Registered to ISO 9001:2015 • Distance between local load controls and sensor Regulatory Approvals should not exceed 60 ft (18 m) line-of-sight or 30 ft (9 m) through walls. LRF2- Sensor Coverage Test • cULusR listed • Dedicated test button • FCC certified • Lens illuminates orange in response to motion during test • IC certified mode • COFETEL certified Wireless Communication Test • ANATEL certified • SUTEL certified • Dedicated test button • Meets CA (U.S.A.) Energy Commission Title 24 • Turn associated loads on and off requirements Timeout Options LRF3- • 1 minute* • CE marked (European Union) • 5 minutes • UKCA (United Kingdom) • 15 minutes (default setting) • TRA type approved (United Arab Emirates) • 30 minutes LRF4- Auto-On Options (Occupancy Versions Only) • iDA registered (Singapore) • Enabled: Sensor turns lights ON and OFF automatically LRF5- (default setting) • WPC type (India) • Disabled**: Lights must be turned ON manually from Power/Performance dimming or switching device. Sensor turns lights OFF automatically • Operating voltage: 3 V- Sensitivity Options • Operating current: 14 μA nominal • Low Activity: (default setting) • Requires one CR 123 lithium battery • Medium Activity: • 10-year battery-life design • High Activity: • Non-volatile memory (saved changes are stored during power loss) * Intended for use in high-activity, briefly-occupied areas only Environment ** There is a 15-second grace period that begins when the lights are automatically turned off, during which the lights will automatically turn • Temperature: 32 °F to 104 °F (0 °C to 40 °C) back on in response to motion. This grace period is provided as a safety and convenience feature in the event the lights turn off while the room is • For indoor use only still occupied, so that the user does not need to manually turn the lights back on. After 15 seconds, the grace period expires and the lights must • Relative humidity: less than 90% non-condensing be manually turned on. Note: For unconditioned environments where the air temperature may approach the temperature of the occupants, additional sensors will be needed to achieve the same coverage. This is true of any sensor that relies exclusively on passive infrared technology. Warranty • Limited Warranty: www.lutron.com/warranty or call 1.844.LUTRON1 (USA/Canada) or 610.282.3800 (Others) for a printed copy. SPECIFICATION SUBMITTAL Page 2 ® Job Name: Model Numbers: Job Number:
Page 3
Radio Powr Savr Wireless Wall-Mount Occupancy and Vacancy Sensors 369481m 3 04.14.26 Installation Overview Sensor Setup • Sensor setup is available as a service by Lutron. For more information, please see the Sensor Layout and Tuning specification submittal (P/N 3601235) at www.lutron.com Sensor Placement • The mounting height of the sensor should be between 6 ft and 8 ft (1.6 m and 2.4 m). • For smaller rooms less than 12 ft × 12 ft (3.7 m × 3.7 m), detection may be improved by mounting the sensor at 6 ft (1.8 m) from the floor. • The ability to detect motion requires that the sensor have line-of-sight of all room occupants. The sensor must have an unobstructed view of the room. DO NOT mount behind or near tall cabinets, shelves, hanging fixtures, etc. The sensor cannot detect occupants through glass objects such as patio or shower doors. • Hot objects and moving air currents can affect the performance of the sensor. To ensure proper operation, the sensor should be mounted at least 4 ft (1.2 m) away from HVAC vents and halogen or incandescent bulbs that are below the ceiling line. • The performance of the sensor depends on a temperature differential between the ambient room temperature and that of room occupants. Warmer rooms may reduce the sensor’s ability to detect occupants. • Distance between local load controls and sensor should not exceed 60 ft (18 m) line-of-sight or 30 ft (9 m) through walls. • Devices emitting Radio Frequency (RF) energy can affect the performance of sensors. To ensure proper operation, sensors should be mounted at least 4 ft (1.2 m) away from devices that emit radio waves (e.g., microwave ovens, wireless routers, or other non-Clear Connect wireless devices). When using Clear Connect - Type X lamps or fuxtures, ensure sensor is mounted at a distance of 2 ft (0.6 m) or greater from the lamp or fixture. SPECIFICATION SUBMITTAL Page 3 ® Job Name: Model Numbers: Job Number:
Page 4
Radio Powr Savr Wireless Wall-Mount Occupancy and Vacancy Sensors 369481m 4 04.14.26 Mounting • 180° and hallway sensors mount directly to wall with Figure A. 180° Wall-Mount Sensor and Hallway Sensor mounting bracket (included). See Figure A. • 90° sensors mount directly in corner or on wall offset away from corner with mounting bracket (included). See Figure B. – Temporary mounting is recommended to test sensor coverage and wireless communication before Mounting Bracket permanently installing the sensor. Temporary mounting: A 3MTM CommandTM adhesive strip is provided for temporarily mounting and testing the sensor. This strip is designed for easy, damage-free removal and is not reusable. Permanent mounting: Mounting bracket, screws, and anchors are provided to mount sensor. • The Flexible Mounting Armature, LRF-ARM-WH (purchased separately), allows sensors to be mounted at greater heights on a ceiling, wall, or other flat surface. – The ball-and-clamp design expands the coverage area for Lutron standard wall-, corner-, or hall-mount sensors. See Figure C. – Common mounting areas: warehouse aisles, loading docks, long hallways. Figure B. 90° Corner-Mount Sensor Figure C. Flexible Mounting Armature Measurements are: in (mm) 3.625 (92) Mounting Bracket 2.18 (55) Mounting Bracket (for wall or ceiling) SPECIFICATION SUBMITTAL Page 4 ® Job Name: Model Numbers: Job Number:
Page 5
Radio Powr Savr Wireless Wall-Mount Occupancy and Vacancy Sensors 369481m 5 04.14.26 Dimensions 4.35 in (110 mm) 1.8 in 1.35 in (46 mm) (34 mm) SPECIFICATION SUBMITTAL Page 5 ® Job Name: Model Numbers: Job Number:
Page 6
Radio Powr Savr Wireless Wall-Mount Occupancy and Vacancy Sensors 369481m 6 04.14.26 Coverage Diagrams 180° Wall-Mount Sensors Models: LRFX-OWLB-P-WH and LRFX-VWLB-P-WH Horizontal Beam Diagram Tested Coverage Area 2 2 Major motion coverage: 3000 ft (278.7 m ) 25 ft (7.6 m) 2 2 Minor motion coverage: 1500 ft (139.4 m ) 20 ft Compliant to NEMA WD7 test grid (shown below) (6.1 m) 10 ft (3.0 m) 15 ft (4.6 m) 0 10 ft 25 ft (3.0 m) (7.6 m) 20 ft 50 ft (6.1 m) (15.2 m) 25 ft 60 ft (7.6 m) (18.3 m) 0 10 ft 20 ft 30 ft 40 ft 50 ft 60 ft (3.0 m) (6.1 m) (9.1 m) (12.2 m) (15.2 m) (18.3 m) Vertical Beam Diagram* 7 ft (2.1 m) 0 0 10 ft 20 ft 30 ft 40 ft 50 ft 60 ft (3.0 m) (6.1 m) (9.1 m) (12.2 m) (15.2 m) (18.3 m) * Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 ft and 8 ft (1.6 m and 2.4 m). SPECIFICATION SUBMITTAL Page 6 ® Job Name: Model Numbers: Job Number:
Page 7
Radio Powr Savr Wireless Wall-Mount Occupancy and Vacancy Sensors 369481m 7 04.14.26 Coverage Diagrams 90° Corner-Mount Sensors Models: LRFX-OKLB-P-WH and LRFX-VKLB-P-WH Horizontal Beam Diagram Tested Coverage Area 2 2 Major motion coverage: 2500 ft (232.3 m ) 2 2 Minor motion coverage: 1225 ft (113.8 m ) Compliant to NEMA WD7 test grid (shown below)
0 ft ) 5 5.2 m (1
5 ft 3 0.7 m) (1 0 0 (10.35 ft 7 m) ( 50 f t ) 15. 5 ft 0 f m 2 m t 3 0.7 m) 515.2 ) (1 ( Vertical Beam Diagram* 7 ft (2.1 m) 0 0 10 ft 20 ft 30 ft 40 ft 50 ft (3.0 m) (6.1 m) (9.1 m) (12.2 m) (15.2 m) * Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 ft and 8 ft (1.6 m and 2.4 m). SPECIFICATION SUBMITTAL Page 7 ® Job Name: Model Numbers: Job Number:
Page 8
Radio Powr Savr Wireless Wall-Mount Occupancy and Vacancy Sensors 369481m 8 04.14.26 Coverage Diagrams Hallway Sensors Models: LRFX-OHLB-P-WH and LRFX-VHLB-P-WH • Designed to mount at the end of a hallway with a clear view down the length of a hall. • Detection at longer distances is best when motion occurs at right angles to the sensor. • Multiple sensors can be used to extend coverage. Maximum Recommended Hallway Length Hall Width Hall Length 6 ft (1.8 m) or less 50 ft (15.2 m) 8 ft (2.4 m) or less 100 ft (30.5 m) 10 ft (3.0 m) or more 150 ft (45.7 m) Top View 5 ft (1.5 m) 0 5 ft (1.5 m) 0 25 ft 50 ft 75 ft 100 ft 125 ft 150 ft (7.6 m) (15.2 m) (22.9 m) (30.5 m) (38.1 m) (45.7 m) Side View* 7 ft (2.1 m) 0 0 25 ft 50 ft 75 ft 100 ft 125 ft 150 ft (7.6 m) (15.2 m) (22.9 m) (30.5 m) (38.1 m) (45.7 m) * Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 ft and 8 ft (1.6 m and 2.4 m) and centered within hallway. Lutron, Clear Connect, Radio Powr Savr, XCT and any related trade dress and logos are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. All other product names, logos, and brands are property of their respective owners. SPECIFICATION SUBMITTAL Page 8 ® Job Name: Model Numbers: Job Number:
Need assistance or looking to source this item?