Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Lutron RF CCO Module – product specifications (369770e, 02.09.26)

Page 1 of 5100%
Text of this document5 pages · 1,127 words

Page 1

product specifications 369770e 02.09.26 RF CCO Module The RF CCO Module is a low-voltage radio frequency (RF) control that provides a single dry contact closure output based on input from RadioRA 2, RadioRA 3, and HomeWorks QS systems. It can be powered by 24 V~ or 24 V- for easy connection and integration into building management, HVAC, VAV, and other 3rd-party systems. • Single contact closure output including both normally open (NO) and normally closed (NC) dry contacts • Maintained or momentary output type • Operates at 24 V~ or 24 V- • Utilizes Lutron Clear Connect RF Technology – refer to model number chart below for frequency band data, and Lutron system compatibility • Screw tabs provided for surface mounting (recommended); or mounts to an electrical junction box through a 1/2 in or 21 mm trade size knockout opening • Complies with requirements for use in a compartment handling environmental air (plenum) per NECR 2011 300.22(C)(3) (LMJ- model only) Models Model Number Region Operating Frequency Band Compatible Voltage Systems LMJ-CCO1-24-B U.S.A., Canada, 24 V~ or 24 V- 431.0 – 437.0 MHz RadioRA 2, Mexico RadioRA 3, LMK-CCO1-24-B Europe, U.A.E. 24 V~ or 24 V- 868.125 – 868.850 MHz HomeWorks QS NOTE: Contact Lutron for frequency band compatibility for your geographic region if it is not indicated above. | www.lutron.com/support Lutron 1

Page 2

product specifications 369770e 02.09.26 RF CCO Module Specification Model Number LMJ-CCO1-24-B, LMK-CCO1-24-B Power IEC PELV/NECR Class 2 Operating voltage: 24 V~ / 24 V- Operating current, nominal: 45 mA (24 V~), 35 mA (24 V-) Typical Power Consumption < 1.0 W Typical power test conditions: all loads off, CCO LED on Regulatory Approvals ULR, UL 2043 Plenum Rated, FCC Approved. Complies with the limits for a Class B device, pursuant to Part 15 of FCC rules, IC, (LMJ- model only), CE, TRA, CITC (LMK- model) Environment Ambient operating temperature: 32 °F to 131 °F (0 °C to 55 °C) Ambient operating humidity: 0% to 90% humidity, non-condensing. Indoor use only. Communications Operates using Clear Connect RF Technology for reliable wireless communication; refer to model number chart on Page 1 for frequency band details. RF range is 30 ft (9 m) from repeaters. Contact Lutron for applications using foil-backed or metallic ceiling tiles. Contact Closure Output Accepts input voltages of 0 to 24 V~ / 0 to 24 V- Resistive Load: 1.0 A (0 to 24 V-), 0.5 A (0 to 24 V~) Provides both normally open (NO) and normally closed (NC) dry contacts. Maintained or momentary output type. Output is latching. Minimum Close Time: 500 ms. Mounting Screw tabs provided for surface mounting (recommended); or mounts to a electrical junction box through a 1/2 in or 21 mm trade size knockout opening. 2 Low Voltage CCO Wiring CCO terminals accept 20 to 16 AWG (0.5 to 1.5 mm ) solid or stranded wire. Limited Warranty www.lutron.com/warranty or call 1.844.LUTRON1 for a printed copy. !WARNING – Entrapment Hazard – May result in serious injury or death. These controls should only be used to control equipment which is visible from every control location. !WARNING – Fire Hazard – May result in serious injury or death. Only use these controls to operate approved load and equipment types. IMPORTANT NOTE: Examples of such equipment which must not be operated by these controls include (but are not limited to) motorized gates, garage doors, industrial doors, microwave ovens, heating pads, fireplaces, space heaters, etc. It is the installer’s responsibility to ensure that the equipment being controlled is visible from every control location and that only suitable equipment is connected to these controls. Failure to do so could result in serious injury or death. Customer Assistance: | 1.844.LUTRON1 (U.S.A. / Canada) 2 Lutron +44.(0)20.7702.0657 (Europe)

Page 3

product specifications 369770e 02.09.26 RF CCO Module Dimensions Dimensions are shown as: in (mm) 1/2 in or 21 mm trade size knockout opening 3.94 3.42 (100) (87) 2.82 1.25 (72) (32) Wiring Diagram (Recommended) NOTE: LMJ- models are supplied with three twist-on wire connectors. LMK- models are supplied with Lever Operated Connectors. See Installation sheets for LMK- models for Lever Operated Connector information. Supply Voltage NOTE: CCO Module supply wires can be connected in any polarity. 24 V~/24 V- Wire Nut (2 Supplied) Mounting screw COM (Common) To CCO controlled device. NOTE: When wiring CCO output, use 2 2 NO NC 20 AWG to 16 AWG (0.5 mm to 1.5 mm ) (Normally Open) (Normally Closed) solid or stranded wire. NOTE: The CCO output may be wired using either the NO or NC terminal. | www.lutron.com/support Lutron 3

Page 4

product specifications 369770e 02.09.26 RF CCO Module Wiring Diagram (Junction Box Optional) NOTE: Some applications (in USA) Junction Box * * require the CCO module to be installed inside an additional junction box. For information about how to perform this installation, please visit www.lutron.com, Application Note Supply Voltage #423 (P/N 048423). Please consult 24 V~ / 24 V- all local and national electric codes for proper installation methods. NOTE: The CCO is not rated to control unclamped, inductive loads. Inductive loads include (but are not limited to): relays, solenoids, and Contact Closure Output motors. To control these types of equipment, a flyback diode must be NC used (DC voltages only). For more information, please see Application NO To 3rd-Party Note #434 (P/N 048434). COM Equipment Customer Assistance: | 1.844.LUTRON1 (U.S.A. / Canada) 4 Lutron +44.(0)20.7702.0657 (Europe)

Page 5

product specifications 369770e 02.09.26 RF CCO Module Communications Wired and RF Configuration (RadioRA 2 and HomeWorks QS) Repeater * RF CCO Module RF CCO Module RF CCO Module 30 ft (9 m) maximum 30 ft (9 m) 30 ft (9 m) maximum maximum RF Link RF Link 1000 ft (305 m) maximum 60 ft (18 m) 1000 ft (305 m) maximum wire length per run maximum wire length per run * In HomeWorks QS systems, use Hybrid Repeaters for range extension. In RadioRA 2, the repeater shown may be either a main repeater (1 required) or auxiliary repeater (up to 4 permitted). RadioRA 3 RF Range Radio Powr Savr RF Pico Radio Powr Savr Occupancy / Vacancy Module Remote Occupancy / Vacancy Sensor Control Sensor 30 ft (9 m) maximum 30 ft (9 m) maximum Processor Wireless Shade Repeater RF Module 60 ft (18 m) maximum All devices must be located within 30 ft (9 m) of a RadioRA 3 processor or wireless repeater. The range can be extended with up to 4 wireless repeaters on a single RF link. Lutron, Clear Connect, HomeWorks, Pico, RadioRA, RadioRA 2, RadioRA 3, Radio Powr Savr, and any related trade dress and logos are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. All other product names, logos, and brands are property of their respective owners. | www.lutron.com/support Lutron 5

Need assistance or looking to source this item?