Text of this document5 pages · 432 words
Page 1
MDM T1350 MOVING DOOR MECHANISM Open Position Closed Position Representative Moving panel TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
MDM T1350 MOVING DOOR MECHANISM PANEL CLOSED Recommended minimum space at end of 107.5 mechanism to allow access to belt tensioner 2730 Area requires access for the motor 0.98 7.87 25 200 Areas requires access from below for switch adjustment 52.36 1330 53.15 1350 Travel PANEL OPEN 0.98 25 52.36 1330 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
MDM T1350 MOVING DOOR MECHANISM GENERAL DIMENSIONS Cable loom to control Boards 0.39 DETAIL C 3.79 10 MDM is fixed from SCALE 1 : 6 96.3 Maximum underneath through Length of Hanger Screws to mounting holes in Fixing Head back of panel the column 7.66 195 3.94 100 Motors located at the end of the mechanism. DETAIL B Recommended to allow access from below for servicing. SCALE 1 : 5 1.60 40.6 5.72 145 107.5 3.94 2730 100 A C A SECTION A-A B SCALE 1 : 3 52.36 1330 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
MDM T1350 MOVING DOOR MECHANISM SWITCH ADJUSTMENT The limit switches can be adjusted using an allen key. Undo the bolts and slide switch to desired position. DETAIL D SCALE 1 : 2 D TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
MDM T1350 CONTROL BOX FOR MOVING DOOR MECHANISM 12.11307.5 CABLE LOOM RS232 PORT IR OUTPUT LENGTH APPROX INDICATOR LED 118 CONTACT 3000 CLOSURE PORT IR LEAD INPUT 3.5mm [0.14"] JACK EMERGENCY STOP CONNECTOR 20 max 0.79 max 0.28 7 8.2 0.32 2.0552.1 8 CORE CABLE MOTOR 5.2 10mm [0.4"] dia. 0.20 5.89 3 CORE CABLE MAINS INPUT EU SPEC: 0.5mm² 149.5 SWITCH LIMITS US SPEC: 20AWG 6mm [0.25"] dia. EU SPEC: 0.5mm² NOTES US SPEC: 20AWG • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 5 FUTUREAUTOMATION