This document could not be shown here. Open the PDF.
Text of this document5 pages · 423 words
Page 1
MDM-T940 MOVING DOOR MECHANISM Closed Position Open Position Representative Door TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
MDM-T940 MOVING DOOR MECHANISM 1 1/16" 27 PANEL CLOSED Recommended minimum space at end of 70 7/8" 1800 mechanism to allow access to belt tensioner Area requires access for the motor 7 7/8" 200 Areas requires access from below for switch adjustment 36" 914 37" 940 1 1/16" 27 PANEL OPEN TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
MDM-T940 MOVING DOOR MECHANISM Cable loom to control Boards GENERAL DIMENSIONS DETAIL C 3/8" 10 3 3/4" Maximum 95 MDM is fixed from Length of Hanger Adjustment underneath through Fixing Head Loosen the nuts and raise or mounting holes in the lower to desired position column Motors located at the end of the mechanism. Recommended to allow access from below for servicing. 7 1/8" 181 3 15/16" DETAIL B 100 7 1/2" ±3/16" 190 ±5 70 7/8" 1800 3/16" 4.4 C A A B SECTION A-A 1 15/16" 50 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
MDM-T940 MOVING DOOR MECHANISM SWITCH ADJUSTMENT The limit switches can be adjusted using an allen key. Undo the bolts and slide switch to desired position. DETAIL D D TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
MDM-T940 MOVING DOOR MECHANISM
307.5 12 1/8"
RS232 PORT IR OUTPUT INDICATOR LED CONTACT CABLE LOOM CLOSURE LENGTH APPROX PORT 118 1/8" IR LEAD INPUT 3000
3.5mm [0.14"] JACK EMERGENCY STOP CONNECTOR 20 max 0.79 max
5/16"
52.1 8 CORE CABLE 2 1/16"
MOTOR 5.2 10mm [0.4"] dia. 3/16" 5 7/8" 3 CORE CABLE MAINS INPUT
EU SPEC: 0.5mm² 149.5 SWITCH LIMITS US SPEC: 20AWG 6mm [0.25"] dia. EU SPEC: 0.5mm² NOTES US SPEC: 20AWG • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 5 FUTUREAUTOMATION