This document could not be shown here. Open the PDF.
Text of this document5 pages · 1,390 words
Page 1
Motor Control Power Module LQSE-4M-D 4-Output AC Motor Controller 369614b 1 10.16.2015 Motor Control Power Module The motor control power module is an interface that provides seamless integration of HomeWorks® QS systems with AC blinds, shades, louvers, projection QS Zn. 1 Zn. 2 Zn. 3 Zn. 4 screens, or any compatible AC motor. It provides four (4) MUX MUX COM Def. T > 65 ºC LQSE-4M-D independently controllable AC raise/lower outputs from a Opt. 1 Opt. 230 V~ 50 / 60 Hz Opt. 2 one common AC input feed. lutron.com +44.(0)20.7702.0657 u M 230 V~ 1,5 A (x8) 8 mm 1,2 N•m LN 1 2 3 4 Features In HomeWorks® QS systems, the motor control power module's high-voltage outputs for motor loads are fully LQSE-4M-D programmable through the HomeWorks® system software. System Example 4 motor control outputs, 1,5 A each (zones 1-4) (cannot be used for non-motor loads) HomeWorksR Power Panel seeTouchR QS Module Wallstation Unit GRAFIK EyeR QS Motor Control Power LUTRON Module QS Link Link Up to 230 V~ Power 100 Control Power Supply total QS devices 1 ® SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 2
Motor Control Power Module LQSE-4M-D 4-Output AC Motor Controller 369614b 2 10.16.2015 Specifications Input Power QS Link Limits • Input voltage: 230 V~ 50/60 Hz • A QS link can have up to 100 zones (outputs) and • 6 A maximum total input current 100 devices • At standby (no motors being driven), power is • Each motor control power module counts as 4 zones less than 1 W (outputs) and 1 device on the QS link • Lightning strike protection meets ANSI/IEEE standard • The motor control power module (LQSE-4M-D) unit 62.31-1980. Can withstand voltage surges of up to does not supply or consume power draw units. When 6 000 V~ and current surges of up to 3 000 A using accessories (such as a keypad), an additional 24 V- power supply or a link power supply must Output Capacity provide power and/or power draw units • 1,5 A maximum motor load per channel For more information on Power Draw Units, see (not for lighting control) "Power Draw Units on the QS Link", • Each zone supports only one motor; do not wire motors Lutron PN 369405, at www.lutron.com/qs in parallel • Raise and Lower outputs are mechanically interlocked to Normal Mode Operation prevent simultaneously activating Raise/Lower outputs • Zone Select button selects the desired zone; raise/ • Designed to withstand 100 000 open/close cycles lower buttons control the selected zone Regulatory Requirements • Supports Open, Close, and Unaffected presets only; • IEC/EN 60669-2-1, EN50428 all other presets are ignored • Lutron Quality Systems registered to ISO 9001.2008 • Does not support shade groups or areas • CE • Does not support discrete shade levels • Does not support scenes Other Power Specifications Configurable Parameters • Standby power: • Minimum On time (also called Jog Time): the minimum - 230 V~: 660 mW time for which the Raise/Lower relay will be turned on • BTU/hour when fully loaded: 5 Configurable from 80 ms to 3520 ms in 80 ms Environment increments • Ambient temperature operating range Default: 80 ms (inside mounting panel): 0 ºC to 40 ºC • Interlock delay: the time both relays are de-energized (32 ºF to 104 ºF) while switching from Raise to Lower, or from Lower to • Calibration point maximum: 65 ºC (149 ºF) Raise • Surrounding air temperature: T 65 ºC Configurable to 320 ms, 560 ms, or 960 ms a Default: 320 ms • Relative humidity: less than 90% non-condensing • Maximum On time (also called Travel Time or Time • For indoor use only to Off): after this time, the relay is turned off as a Terminals precaution 2 Configurable from 10 seconds to 450 seconds in • Mains Wiring: 1,0 to 4,0 mm (18 to 12 AWG) 10-second increments 2 • Zone Wiring: 1,0 to 4,0 mm (18 to 12 AWG) Default: 80 seconds • QS Link Wiring: See Wiring: QS Link Mounting • Use an IP20 (minimum) rated consumer panel or breaker panel with integrated DIN rail • Width = 9 DIN modules (161,7 mm/6,4 in) 2 ® SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 3
Motor Control Power Module LQSE-4M-D 4-Output AC Motor Controller 369614b 3 10.16.2015 Mechanical Dimensions QS Zn. 1 Zn. 2 Zn. 3 Zn. 4 MUX MUX COM Def. 89,7 mm T > 65 ºC LQSE-4M-D a Opt. 1 (3,5 in) Opt. 230 V~ 50 / 60 Hz Opt. 2 lutron.com +44.(0)20.7702.0657 u M 230 V~ 1,5 A (x8) 8 mm 1,2 N•m LN 1 2 3 4 161,7 mm (6,4 in) (Equal to 9 DIN modules) 60,6 mm (2,4 in) 3 ® SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 4
Motor Control Power Module LQSE-4M-D 4-Output AC Motor Controller 369614b 4 10.16.2015 Mains Voltage and Load Wiring QS Zn. 1Zn. 2Zn. 3Zn. 4 MUX MUX COM Zone Select buttons Def. Ta > 65 ºC Opt. 1 Opt. 230 V~ 50 / 60 Hz Opt. 2 Raise/Lower buttons lutron.com +44.(0)20.7702.0657 u M 230 V~ 1,5 A (x8) 8 mm 1,2 N•m LN 1 2 3 4 L N G Button Functions QS Zone Select buttons: Zn. 1 Zn. 2 Zn. 3 Zn. 4 MUX MUX COM Select desired zone Def.LED LED indicates which zone is T > 65 ºC LQSE-4M-D a Opt. 1 selected Opt. 230 V~ 50 / 60 Hz Opt. 2 lutron.com +44.(0)20.7702.0657 u M 230 V~ 1,5 A (x8) 8 mm Raise/Lower buttons: Hot/Live 1,2 N•m LN 1 2 3 4 QS Zn. 1 Zn. 2 Zn. 3 Zn. 4 MUX MUX COM Raise/Lower selected zone From Distribution Panel Def. LEDs indicate which T > 65 ºC LQSE-4M-D a Neutral Feed Opt. 1 direction (Raise/Stop/Lower) Opt. 230 V~ 50 / 60 Hz Opt. 2 lutron.com +44.(0)20.7702.0657 is active u Raise/ M 230 V~ 1,5 A (x8) Lower/ 8 mm N 1,2 N•m LN 1 2 3 4 Open Close LEDs Motor Load Wiring from Distribution Panel to Note Motor Control Power Module Before proceeding with the line voltage/mains wiring, • Turn off all circuit breakers or isolators feeding the set the upper/open and lower/close limits for each motor control power module unit at distribution panel. motor. Refer to the manufacturer's instructions for your • Run hot/live, neutral, and ground/earth ( ) wires from specific motor. a 230 V~ 50/60 Hz feed to the motor control power module. • Follow appropriate local and national codes to avoid violating required separation guidelines between Mains wiring and IEC PELV/NEC® Class 2 wiring. 4 ® SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 5
Motor Control Power Module LQSE-4M-D 4-Output AC Motor Controller 369614b 5 10.16.2015 Wiring: QS Link IEC PELV/NEC® Class 2 QS Link Wiring • Link communicates using IEC PELV/NEC® Class 2 QS Zn. 1 Zn. 2 Zn. 3 Zn. 4 MUX MUX COM wiring. Def. T > 65 ºC LQSE-4M-D a Opt. 1 Opt. 230 V~ 50 / 60 Hz Opt. 2 • Follow all applicable national and local codes for lutron.com +44.(0)20.7702.0657 u M 230 V~ 1,5 A (x8) 8 mm 1,2 N•m LN 1 2 3 4 proper circuit separation and protection. • Wiring may be daisy chained or t-tapped. • Total length of QS link must not exceed 610 m (2 000 ft). • For lengths under 150 m (500 ft), use 2 1,0 mm (18 AWG) conductor for control power (COM). 2 (12 AWG) • For lengths over 150 m (500 ft), use 4,0 mm conductor for control power (COM). 2 (22 AWG) • Use one, twisted-shielded pair of 0,5 mm for data link (MUX, MUX). (1) COM ) (2) (no connect To additional (3) MUX QS devices (4) MUX Wire Sizes (check compatibility in your area) QS Link Wiring Length Wire Gauge Lutron Cable Part Number Less than 150 m (500 ft) Common (terminal 1) 2 1 1,0 mm (18 AWG) GRX-CBL-346S (non-plenum) Data (terminals 3 and 4) GRX-PCBL-346S (plenum) 2 1 twisted, shielded pair 0,5 mm (22 AWG) 150 to 610 m Common (terminal 1) 2 (500 to 2 000 ft) 1 4,0 mm (12 AWG) GRX-CBL-46L (non-plenum) Data (terminals 3 and 4) GRX-PCBL-46L (plenum) 2 1 twisted, shielded pair 0,5 mm (22 AWG) 5 ® SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Need assistance or looking to source this item?