Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Future Automation SPS-VS-7 technical sheet

Page 1 of 10100%
Text of this document10 pages · 1,882 words

Page 1

SPS-VS-7 SLIDING PANEL MECHANISM - VERTICAL SPLIT TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

SPS-VS-7 SLIDING PANEL MECHANISM - VERTICAL SPLIT SPS-V - VERTICAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN HEIGHT MAX SCREEN HEIGHT SPS-V-5 Vertical - Single Panel 700 [27 9/16"] 800 [31 1/2"] SPS-V-6 Vertical - Single Panel 801 [31 9/16"] 950 [37 3/8"] SPS-V-7 Vertical - Single Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-V-8 Vertical - Single Panel 1101[ 43 3/8"] 1250[ 49 3/16"] SPS-VS - VERTICAL SPLIT - DOUBLE PANEL SPS-VS-5 Vertical - Double Splitting Panel 700 [27 9/16"] 800 [31 1/2"] SPS-VS-6 Vertical - Double Splitting Panel 801 [31 9/16"] 950 [37 3/8"] SPS-VS-7 Vertical - Double Splitting Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-VS-8 Vertical - Double Splitting Panel 1101[ 43 3/8"] 1250[ 49 3/16"] SPS-HZ - HORIZONTAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN WIDTH MAX SCREEN WIDTH SPS-HZ-6 Horizontal - Single Panel 1400 [55 1/8"] 1600 [63"] SPS-HZ-7 Horizontal - Single Panel 1601 [63 1/16"] 1850 [72 13/16"] SPS-HZ-8 Horizontal - Single Panel 1851 [72 7/8"] 2100 [82 11/16"] SPS-HZS - HORIZONTAL SPLIT- DOUBLE PANEL SPS-HZS-6 Horizontal - Double Splitting Panel 1400 [55 1/8"] 1600 [63"] SPS-HZS-7 Horizontal - Double Splitting Panel 1601 [63 1/16"] 1850 [72 13/16"] SPS-HZS-8 Horizontal - Double Splitting Panel 1851 [72 7/8"] 2100 [82 11/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

SPS-VS-7 SLIDING PANEL MECHANISM - VERTICAL SPLIT 2. Panel Retracts 1. Panel Closed SPECIFICATION MEASUREMENTS Minimum Screen Height 951 [37 7/16"] Maximum Screen Height 1100[ 43 5/16"] Minimum Screen Width 1550 [61"] Maximum Screen Width 2050 [80 11/16"] Maximum Moving Panel Weight 30Kg (66lbs) per panel Maximum Screen Weight 100Kg (220lbs) Total Mechanism Weight TBC Packaging Dimensions (LxWxH) TBC Shipping Weight TBC 4. Screen Advances 3. Panel Lifts Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption Max. 120W Power Consumption Standby 3W Mounting Patterns Supported VESA 200 - 800 W x 200 - 600 H Control Options IR Remote, RS232, Contact Closure Product Options / Features QA2 pairing option Package Contents Mechanism, IR remote control, Bolt Pack Marine Suitable Yes (Indoor) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

SPS-VS-7 SLIDING PANEL MECHANISM - VERTICAL SPLIT CABINET DIMENSIONS - WIDTH AND HEIGHT 46 7/16" Height Below Height Below 1180 5 5/16" 5 5/16" Screen Height Install Height clearance overidden Screen Center Line Screen Center Line 135 135 SECTION A-A 50 3/8" 96 7/8" 50 3/8" 46 7/16" 43 5/16" 37 3/8" 1280 2460 1280 1180 1100 950 Internal Cabinet Width = Screen Width + 280 B 96 7/8" Screen Width Install Width 2460 SECTION B-B SECTION B-B Maximum Screen Height Minimum Screen Height 61" 80 11/16" 11" 1550 2050 Screen Width + 280 43 5/16" 1100 B 37 3/8" 950 50 L C 1 15/16" Clearance 61" 1550 (Screen Height - 5) / 2 Moving Panel Height = 1180 A A

80 11/16" 46 7/16" 2050 20 13/16" 11" Height Above Screen

280 Opening Height = Screen Height +10 Opening Width = C Screen L Screen Width +10 2460 2460 2440 2440 Opening Height = 96 7/8" 96 7/8" Screen Height +10 96 1/16" 96 1/16" Opening Width = Opening Height Install Height Install Height Screen Width +10

Mechanism Height Mechanism Height L C 20 13/16"

1280 50 3/8" Height Below Screen (Screen Height - 5) / 2 Moving Panel Height = B The install height for the SPS-VS-7 is always 2460 [96 7/8"] regardless of the B screen. C TECHNICAL SHEET The SPS-VS will always require additional space below the seceen L UK +44 (0) 1438 833577 US +1 (603) 742 9181 C ISSUE 001 compared to above the screen . L WWW NET . . SHEET 4 FUTUREAUTOMATION

Page 5

SPS-VS-7 SLIDING PANEL MECHANISM - VERTICAL SPLIT Screen - OUT Screen - IN 1 3/16" CABINET DIMENSIONS - DEPTH 30 Moving Panel D A The minimum depth of 205mm [8 1/16"] allows for a Thickness maximum screen depth of 30mm [1 3/16"]. Screens with a greater thickness will need the cabinet 1 15/16" 13/16" 50 depth to increase i.e. a 100mm [3 15/16"] thick screen 20 Max. Front Panel will require a cabinet of 275mm [10 13/16""]. Front Panel and Batton Thickness Thickness Screens thinner than 30mm [1 3/16"] must still use the minimum 205mm [8 1/16"] cabinet depth. DETAIL D A SCALE 1 : 3 A 2 9/16" 65 Retract Recomended batten to support front panel above opening The moving panel retracts back by 65mm [2 9/16"] before splitting. For this reason it is advised the front panel work and support batten is no more than 50mm [1 15/16"] thick to give 15mm [9/16"] clearance. A Thicker panels are possible, but will add to the cabinet depth and require customisation to the mechanism design. 8 1/16" 3/8" 205 10 Minimum Internal Mount Bracket to TECHNICAL SHEET Cabinet Depth Back of Front Panels UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 5 FUTUREAUTOMATION

Page 6

A SPS-VS-7 SLIDING PANEL MECHANISM - VERTICAL SPLIT ADVANCE - SERVICE ADVANCE - IN AB - ADVANCE BRACKET ADVANCE - OUT The Advance Bracket has a service mode that can be used during installation and servicing of the mechanism and the screen. This allows the screen to be pulled out from the wall to provide access to rear of the screen and inside the mechanism during A A 3 15/16" fitting. 100 43 5/16" 1100 A A 24 7/16" 622 Max Mount Height A 31 1/2" 800 Max Mount Width 17 11/16" 3 15/16" 450 100 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 6 FUTUREAUTOMATION

Page 7

SPS-VS-7 SLIDING PANEL MECHANISM - VERTICAL SPLIT CABINET DETAILING & ACCESS The SPS mechanism requires certain access for installation Advance Bracket and to be serviced. For installation the top panel must be removable to provide access to all the fixing points of the SPS mechanism. For servicing the best option is to have the areas to the left and right of the opening on hinges. This will provide enough Top Panel access to everything that will be needed to service and (removable for installation) maintain the mechanism. Alternatively the side panels could Hinging side panel be made to be easily removable on suitable catches / fixings. (removable for service & maintenance) The Moving Panel Mechanism mounts to the side walls of the cabinet, and the Advance Bracket mounts to the back of the cabinet. It is essential that these surfaces can take the weight of the mechanism, moving panel and screen. Moving panel bracket The mechanism is supplied with a control box on a 3m [10'] flying lead. This must be fitted in an easily accessible location. This will be the first item to be checked if there is an issue with the mechanism. Mains power and control connections (IR sensor / receiver, contact closure, RS232) are all made at Hinging side panel the control box. (removable for service & maintenance) Motor Telescopic Drive shaft Mechanism Cables Power Cables Control box wiring loom must be routed To Mains Power to the bottom left corner of the cabinet Bottom panel (removable for service & maintenance) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 7 FUTUREAUTOMATION

Page 8

SPS-VS-7 SLIDING PANEL MECHANISM - VERTICAL SPLIT CONTROL BOX

207 8 1/8"

RS232 PORT IR OUTPUT INDICATOR LED CONTACT CLOSURE PORT EMERGENCY STOP IR LEAD INPUT CONNECTOR 3.5mm [0.14"] JACK max CABLE LOOM 20 LENGTH APPROX 13/16" 8 CORE CABLE 118 1/8" 3000 SPS SWITCHES 10mm [3/8"] dia. EU SPEC: 0.5mm² US SPEC: 20AWG 1/4"

2 CORE CABLE

SPS MOTOR 8

10mm [3/8"] dia. 5/16"

EU SPEC: 4mm² US SPEC: 12AWG 52 2 1/16" MAINS INPUT

8 CORE CABLE ADVANCE BRACKET 5 5 7/8" 10mm [3/8"] dia. 3/16" 150

EU SPEC: 0.5mm² US SPEC: 20AWG NOTES • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 8 FUTUREAUTOMATION

Page 9

1. Mount the SPS side channels to the side walls of the cabinet. SPS-VS-7 Ensure the mechanism mount brackets are positioned 10mm back from the edge of the front SLIDING PANEL MECHANISM - VERTICAL SPLIT panels. 2. <PARA >Install the telescopic drive shaft between both sides of INSTALLATION OVERVIEW Up Switch the mechanism. ensure that the moving panel brackets are at the same height. 3. Run the mechanism, adjust the up switch so that the carriages moves the height of the moving panel + 25mm [1"]. C Rear View 1. Mount the mechanism side channels to the side walls of the Down Switch cabinet. Ensure the mechanism mount brackets are positioned 10mm back from the edge of the front panels. Up Switch Adjustment Loosen the bolt and slide the switch striker to the desired position. Ensure the bolt is tightened after adjustment. Switch Striker 2. Install the telescopic drive shaft between both sides of the mechanism. Ensure that the 4. Mount the moving panel to the moving panel brackets are at the same height. moving panel brackets 110mm from the base of the moving panel. 5. mount the moving panel back onto the mechanism, use the slots in the mount brackets to align the panel and get it into the desired position TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 9 FUTUREAUTOMATION

Page 10

SPS-VS-7 SLIDING PANEL MECHANISM - VERTICAL SPLIT INSTALLATION OVERVIEW 4. Mount the moving panel to the moving panel brackets 15mm 5. Mount the moving panel back onto the mechanism, use the slots in the from the base of the moving panel and 94mm in from the edge. mount brackets to align the panel and get it into the desired position. 3 11/16" 3 11/16" 94 94 3 11/16" 94 Rear View of moving panel

110 110 9/16" 4 5/16" 4 5/16"

15

1. Mount the SPS side channels to the side walls of the cabinet. Ensure 3 11/16" Recommended to use 5mm the mechanism mount 94 9/16" shims to align the top moving brackets are positioned 15 panel with the lower moving 10mm back from the panel. edge of the front panels. 2. <PARA >Install the 9/16" telescopic drive shaft 15 between both sides of Moving panel the mechanism. ensure bracket that the moving panel brackets are at the same height. Recommended to use 5mm shims to align the moving panel with the base of the aperture. 9/16" 15 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 10 FUTUREAUTOMATION

Need assistance or looking to source this item?