SPS-VS-6 SLIDING PANEL MECHANISM - VERTICAL SPLIT TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
SPS-VS-6 SLIDING PANEL MECHANISM - VERTICAL SPLIT SPS-V - VERTICAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN HEIGHT MAX SCREEN HEIGHT SPS-V-5 Vertical - Single Panel 700 [27 9/16"] 800 [31 1/2"] SPS-V-6 Vertical - Single Panel 801 [31 9/16"] 950 [37 3/8"] SPS-V-7 Vertical - Single Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-V-8 Vertical - Single Panel 1101[ 43 3/8"] 1250[ 49 3/16"] SPS-VS - VERTICAL SPLIT - DOUBLE PANEL SPS-VS-5 Vertical - Double Splitting Panel 700 [27 9/16"] 800 [31 1/2"] SPS-VS-6 Vertical - Double Splitting Panel 801 [31 9/16"] 950 [37 3/8"] SPS-VS-7 Vertical - Double Splitting Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-VS-8 Vertical - Double Splitting Panel 1101[ 43 3/8"] 1250[ 49 3/16"] SPS-HZ - HORIZONTAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN WIDTH MAX SCREEN WIDTH SPS-HZ-6 Horizontal - Single Panel 1400 [55 1/8"] 1600 [63"] SPS-HZ-7 Horizontal - Single Panel 1601 [63 1/16"] 1850 [72 13/16"] SPS-HZ-8 Horizontal - Single Panel 1851 [72 7/8"] 2100 [82 11/16"] SPS-HZS - HORIZONTAL SPLIT- DOUBLE PANEL SPS-HZS-6 Horizontal - Double Splitting Panel 1400 [55 1/8"] 1600 [63"] SPS-HZS-7 Horizontal - Double Splitting Panel 1601 [63 1/16"] 1850 [72 13/16"] SPS-HZS-8 Horizontal - Double Splitting Panel 1851 [72 7/8"] 2100 [82 11/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
SPS-VS-6 SLIDING PANEL MECHANISM - VERTICAL SPLIT 2. Panel Retracts 1. Panel Closed SPECIFICATION MEASUREMENTS Minimum Screen Height 801 [31 1/2"] Maximum Screen Height 950 [37 3/8"] Minimum Screen Width 1400 [55 1/8"] Maximum Screen Width 1900 [74 13/16"] Maximum Moving Panel Weight 30Kg (66lbs) per panel Maximum Screen Weight 100Kg (220lbs) Total Mechanism Weight TBC Packaging Dimensions (LxWxH) TBC Shipping Weight TBC 4. Screen Advances 3. Panel Lifts Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption Max. 120W Power Consumption Standby 3W Mounting Patterns Supported VESA 200 - 800 W x 200 - 600 H Control Options IR Remote, RS232, Contact Closure Product Options / Features QA2 pairing option Package Contents Mechanism, IR remote control, Bolt Pack Marine Suitable Yes (Indoor) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
SPS-VS-6 SLIDING PANEL MECHANISM - VERTICAL SPLIT CABINET DIMENSIONS - WIDTH AND HEIGHT 43 1/2" 1105 5 5/16" 5 5/16" Height Below Screen Height Above Screen clearance overidden Screen Height Install Height 135 135 Center Line Center Line SECTION A-A 47 7/16" 37 3/8" 90 15/16" 43 1/2" 47 7/16" 31 1/2" 1205 Internal Cabinet Width = Screen Width + 280 950 2310 1105 1205 800
B 90 15/16" SECTION B-B SECTION B-B Screen Width Install width 2310 Minimum Screen Height Maximum Screen Height 37 3/8" 74 13/16" 55 1/8"
Screen Width + 280 B 950 1900 1400
31 1/2" 800 L C (Screen Height - 5) / 2 1105 Moving Panel Height = 43 1/2"
A A 55 1/8" 20 Height Above Screen 13/16" 1400
74 13/16" 1900 C Screen L Opening Height = Opening Width = Screen Height +10 2310 2310 2290 2290 Screen Width +10 90 3/16" 90 3/16" 90 15/16" 90 15/16" Opening Height Install Height Install Height
Opening Height = Screen Height +10 Mechanism Height Mechanism Height Opening Width = Screen Width +10 20 13/16" L C
1205 47 7/16" Height Below Screen (Screen Height - 5) / 2 Moving Panel Height = B The install height for the SPS-VS-7 is always 2460 [96 7/8"] regardless of the screen. B C TECHNICAL SHEET The SPS-VS will always require additional space below the seceen L UK +44 (0) 1438 833577 US +1 (603) 742 9181 C ISSUE 001 compared to above the screen . L WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
SPS-VS-6 SLIDING PANEL MECHANISM - VERTICAL SPLIT Screen - OUT Screen - IN 1 3/16" CABINET DIMENSIONS - DEPTH 30 Moving Panel D A The minimum depth of 205mm [8 1/16"] allows for a Thickness maximum screen depth of 30mm [1 3/16"]. Screens with a greater thickness will need the cabinet 1 15/16" 13/16" 50 depth to increase i.e. a 100mm [3 15/16"] thick screen 20 Max. Front Panel will require a cabinet of 275mm [10 13/16""]. Front Panel and Batton Thickness Thickness Screens thinner than 30mm [1 3/16"] must still use the minimum 205mm [8 1/16"] cabinet depth. DETAIL D A SCALE 1 : 3 A 2 9/16" 65 Retract Recomended batten to support front panel above opening The moving panel retracts back by 65mm [2 9/16"] before splitting. For this reason it is advised the front panel work and support batten is no more than 50mm [1 15/16"] thick to give 15mm [9/16"] clearance. A Thicker panels are possible, but will add to the cabinet depth and require customisation to the mechanism design. 8 1/16" 3/8" 205 10 Minimum Internal Mount Bracket to TECHNICAL SHEET Cabinet Depth Back of Front Panels UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 5 FUTUREAUTOMATION
Page 6
A SPS-VS-6 SLIDING PANEL MECHANISM - VERTICAL SPLIT ADVANCE - SERVICE ADVANCE - IN AB - ADVANCE BRACKET ADVANCE - OUT The Advance Bracket has a service mode that can be used during installation and servicing of the mechanism and the screen. This allows the screen to be pulled out from the wall to provide access to rear of the screen and inside the mechanism during A A 3 15/16" fitting. 100 43 5/16" 1100 A A 24 7/16" 622 Max Mount Height A 31 1/2" 800 Max Mount Width 17 11/16" 3 15/16" 450 100 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 6 FUTUREAUTOMATION
Page 7
SPS-VS-6 SLIDING PANEL MECHANISM - VERTICAL SPLIT CABINET DETAILING & ACCESS The SPS mechanism requires certain access for installation Advance Bracket and to be serviced. For installation the top panel must be removable to provide access to all the fixing points of the SPS mechanism. For servicing the best option is to have the areas to the left and right of the opening on hinges. This will provide enough Top Panel access to everything that will be needed to service and (removable for installation) maintain the mechanism. Alternatively the side panels could Hinging side panel be made to be easily removable on suitable catches / fixings. (removable for service & maintenance) The Moving Panel Mechanism mounts to the side walls of the cabinet, and the Advance Bracket mounts to the back of the Moving panel bracket cabinet. It is essential that these surfaces can take the weight of the mechanism, moving panel and screen. The mechanism is supplied with a control box on a 3m [10'] flying lead. This must be fitted in an easily accessible location. This will be the first item to be checked if there is an issue with the mechanism. Mains power and control connections Hinging side panel (IR sensor / receiver, contact closure, RS232) are all made at (removable for service the control box. & maintenance) Motor Telescopic Drive shaft Mechanism Cables Power Cables Control box wiring loom must be routed To Mains Power to the bottom left corner of the cabinet Bottom panel (removable for service & maintenance) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 7 FUTUREAUTOMATION
Page 8
SPS-VS-6 SLIDING PANEL MECHANISM - VERTICAL SPLIT CONTROL BOX
207 8 1/8"
RS232 PORT IR OUTPUT INDICATOR LED CONTACT CLOSURE PORT IR LEAD INPUT EMERGENCY STOP 3.5mm [0.14"] JACK CONNECTOR max CABLE LOOM 20 LENGTH APPROX 13/16" 8 CORE CABLE 118 1/8" 3000 SPS SWITCHES 10mm [3/8"] dia. EU SPEC: 0.5mm² US SPEC: 20AWG 1/4"
2 CORE CABLE
SPS MOTOR 8
10mm [3/8"] dia. 5/16"
EU SPEC: 4mm² US SPEC: 12AWG 52 2 1/16" MAINS INPUT
8 CORE CABLE ADVANCE BRACKET 5 5 7/8" 10mm [3/8"] dia. 3/16" 150
EU SPEC: 0.5mm² US SPEC: 20AWG NOTES • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 8 FUTUREAUTOMATION
Page 9
1. Mount the SPS side channels to the side walls of the cabinet. SPS-VS-6 Ensure the mechanism mount brackets are positioned 10mm back from the edge of the front SLIDING PANEL MECHANISM - VERTICAL SPLIT panels. 2. <PARA >Install the telescopic drive shaft between both sides of INSTALLATION OVERVIEW Up Switch the mechanism. ensure that the moving panel brackets are at the same height. 3. Run the mechanism, adjust the up switch so that the carriages moves the height of the moving panel + 25mm [1"]. C Rear View 1. Mount the mechanism side channels to the side walls of the cabinet. Ensure the mechanism Down Switch mount brackets are positioned 10mm back from the edge of the front panels. Up Switch Adjustment Loosen the bolt and slide the switch striker to the desired position. Ensure the bolt is tightened after adjustment. Switch Striker 2. Install the telescopic drive shaft between both 4. Mount the moving panel to the sides of the mechanism. Ensure that the moving panel brackets 110mm from moving panel brackets are at the same height. the base of the moving panel. 5. mount the moving panel back onto the mechanism, use the slots in the mount brackets to align the panel and get it into the desired position TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 9 FUTUREAUTOMATION
Page 10
SPS-VS-6 SLIDING PANEL MECHANISM - VERTICAL SPLIT INSTALLATION OVERVIEW 4. Mount the moving panel to the moving panel brackets 15mm 5. Mount the moving panel back onto the mechanism, use the slots in the from the base of the moving panel and 94mm in from the edge. mount brackets to align the panel and get it into the desired position. 3 11/16" 3 11/16" 94 94 3 11/16" 94 Rear View of moving panel
110 110 4 5/16" 4 5/16"
9/16" 15 1. Mount the SPS side channels to the side walls of the cabinet. Ensure 3 11/16" Recommended to use 5mm the mechanism mount 94 9/16" shims to align the top moving brackets are positioned 15 panel with the lower moving 10mm back from the panel. edge of the front panels. 2. <PARA >Install the 9/16" telescopic drive shaft 15 between both sides of Moving panel the mechanism. ensure bracket that the moving panel brackets are at the same height. Recommended to use 5mm shims to align the moving panel with the base of the aperture. 9/16" 15 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 10 FUTUREAUTOMATION