Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Future Automation RTE7 technical sheet

Page 1 of 8100%
Text of this document8 pages · 916 words

Page 1

EDIT CUSTOM PROPERTIES 29. TITLE TO DESIRED RTE-7 PRODUCT CODE RACK TERMINATION ENCLOSURE 30. SUBHEADING TO DESIRED PRODUCT DESCRIPTION EDIT CUSTOM PROPERTIES TECHNICAL SHEET 31. ISSUE NO. UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 009 TO DESIRED ISSUE NUMBER WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

RTE-7 RACK TERMINATION ENCLOSURE DESIGN HIGHLIGHTS UPPER COVER HAS CABLE TIE POINTS FOR MANAGING CABLE LOOM TOO RACK. A premium quality enclosure to allow in-wall wiring terminations for an AV rack installation. Enclosure fits in a standard 14" wide (16" centres) 6" HIGH UPPER COVER EASILY REMOVED single stud bay and is under 4" deep in wall. PROVIDING ACCESS TO INCOMING CABLES. CENTRAL CABLE TRUNKING HAS ENTIRE TERMINATION FRAME/S CAN 3" SQUARE INTERNAL SPACE BE REMOVED WITH JUST 6 SCREWS FOR CONTAINING CABLE LOOM. PROVIDING UNOBSTRUCTED ACCESS INTO THE ENCLOSURE. FRONT COVER OF CABLE CONNECTOR PLATES AVAILABLE TRUNKING HOOKS OFF EASILY IN DIFFERENT FORMATS. WITH NO TOOLS REQUIRED. WALL FLANGE ENSURES A NEAT HINGING CONNECTOR FINISH TO THE INSTALLATION. HATCHES (90 DEG MAX) FOR EASE OF ACCESS TO REAR CONNECTIONS AND CABLES. POWDER COATED FINISH HATCHES HELD SHUT WITH THROUGHOUT. MAGNETS FOR EASE OF ACCESS WITH TOOLS. GROUND / EARTHING BAR 8" HIGH LOWER COVER CAN BE SCREEN PRINTED WITH INSTALLER DETAILS, LOGO, ETC. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 009 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

RTE-7 RACK TERMINATION ENCLOSURE DESIGN HIGHLIGHTS OPTIONAL GUARD PLATES REMOVABLE CABLE CONDUIT SECTION Guard plates can be added after installation Entire Cable management conduit section is complete to ensure external connections is easily removed with a simple hook on- are not tampered with or accidentally off feature. damaged. This allows the rack wiring to remain Connector hatches can still be opened enclosure and secure as part of the AV when guards are in place. rack when delivered to site. This can be easily fitted to the RTE enclosure and Product Order Code: RTE-GP connection made quickly and efficiently. REMOVABLE CONDUIT COVER PANEL Conduit cover is also removed with a simple hook on-off design. GUARD PLATES PROTECT EXTERNAL CONNECTIONS CONDUIT FRONT COVER PANEL CABLE CONDUIT SECTION TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 009 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

RTE-7 RACK TERMINATION ENCLOSURE SUPPLIED PARTS THREE STANDARD TERMINATION PLATES As standard, the RTE7 will be supplied with these three standard types of plates. These can be ordered separately should they be required. BLANKING PLATES AUDIO TERMINATION PLATES KEYSTONE TERMINATION PLATES Used to blank off unused windows in the hinging Populated with Phoenix Contact style pass through Ready to be populated with any keystone based RTE hatches. connectors on both sides, suitable for 14 AWG cable. connector. Total Quantity supplied = 6 Total Quantity supplied = 6 Total Quantity supplied = 24 Product Order Code: RTE-BLP Product Order Code: RTE-ATP Product Order Code: RTE-KTP TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 009 WWW NET . . SHEET 4 FUTUREAUTOMATION

Page 5

RTE-7 RACK TERMINATION ENCLOSURE INTERNAL WIRING DETAILS GENERAL CABLES ENTER FROM ABOVE CABLE TIE POINTS WIRING DETAILS & LAYOUT For a hinging connector group, the cables going to the upper connectors should be Cables should be kept as neat and tidy as possible within tied to the higher cable tie points on the cable management plate. For the lower the enclosure. There are numerous cable tie points connectors, cables should be tied to the lower points on the plate, as shown below. available in the rear of the RTE enclosure. Cables running to each hinging connector assembly Cable should be tied to the cable management plate directly Management above, as shown here, right. Plate 1 Higher Tie Hinging for Upper Connector Connectors Group 1 Cable Management Plate 2 Lower Tie for Lower Hinging Connectors Connector Group 2 Cable Management Plate 3 Hinging Connector Group 3 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 009 WWW NET . . SHEET 5 FUTUREAUTOMATION

Page 6

RTE-7 RACK TERMINATION ENCLOSURE EXTERNAL WIRING DETAILS WIRING HARNESS CABLE SEPARATION Ideally cables should be separated in the central conduit section as shown here. To To There should be two wiring harnesses made, AV AV one for each side of the RTE enclosure. Rack Rack TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 009 WWW NET . . SHEET 6 FUTUREAUTOMATION

Page 7

RTE-7 RACK TERMINATION ENCLOSURE FIBRE WIRING DETAILS FIBRE CONNECTIONS KEPT TO LOWER SECTION OF ENCLOUSRE Ideally fibre cables should be routed into the enclsoure from below, keeping these separate from the other AV cables in the enclosure. By fitting the RTE-FSA assembly (sold separtely - shown below), fibre cables can be managed neatly and excess cable length wound around configurable spools. Strain relief is provided by using ties around the numerous slots at the top of the assembly. Product Order Code: RTE-FSA FIBRE CABLES ENTER FROM BELOW TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 009 WWW NET . . SHEET 7 FUTUREAUTOMATION

Page 8

RTE-7 RACK TERMINATION ENCLOSURE 13 7/8" 353 DIMENSIONS 2 1/2" 63 4 x Dimensions apply for the RTE-7 wiring enclosure. 4 7/8" 124

150 5 7/8"

1333 52 1/2"

298 11 3/4"

1326 1355 53 3/8" 52 3/16"

14"

356

200 7 7/8"

3 13/16" 97 15 7/8" 404 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 009 WWW NET . . SHEET 8 FUTUREAUTOMATION

Need assistance or looking to source this item?