PH2 PROJECTOR HINGE MECHANISM INSTALLATION INSTRUCTIONS ISSUE 007
Page 3
SAFETY DISCLAIMER IMPORTANT SAFETY INSTRUCTIONS BELOW WARNING: Failure to provide adequate structural strengthening, prior to installation can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure the structure to which the component is affixed can support four times the weight of the component and any additional apparatus mounted to the component. WARNING: Do not exceed the weight capacity for this product as listed below. This can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure that the total combined weight of all attached components does not exceed that of the maximum figure stated. WARNING: Risk of death or serious injury may occur when children climb on audio and/or video equipment or furniture. A remote control or toys placed on the furnishing may encourage a child to climb on the furnishing and as a result the furnishing may tip over on to the child. WARNING: Risk of death or serious injury may occur. Relocating audio and/or video equipment to furniture not specifically designed to support audio and/or video equipment may result in death or serious injury due to the furnishing collapsing or over turning onto a child or adult. WARNING – RISK OF INJURY! Only for use with equipment weighing 33LBS (15KG) OR LESS. Use with heavier projectors/equipment may lead to instability causing tip over or failure resulting in death or serious injury. Bracket Suitable for Residential and Commercial Use. ADDITIONAL WARNINGS: 1. Keep all documentation/instructions after fitting. 2. Read all technical instructions fully before installation and use. It is the installer’s responsibility to ensure that all documentation is passed on to the end user and read fully before operation. 3. Do not use near water or outdoors unless the product has been specifically designed to do so. 4. Protect any cables or cords being used near this bracket from being walked on or pinched to prevent damage and risk of injury. 5. Use this product only for its intended purpose as described in the product instructions and only use attachments/ accessories specified by the manufacturer. 6. Do not operate the product if it is damaged in any way, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Contact the original installer/manufacturer to arrange repair or return. WARNING - To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Clean only with a dry cloth and always unplug any electrical items being used in conjunction with this product before cleaning. Future Sound & Vision trading as Future Automation intend to make this and all documentation as accurate as possible. However, Future Automation makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without prior notice or obligation of any kind. Future Automation makes no representation of warranty, expressed or implied, regarding the information contained herein. Future Automation assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document. 1
Page 4
PRODUCT WARRANTY & RISK ASSESSMENT WARRANTY INFORMATION WARNING - The warranty offered for this product shall be annulled if the product is used improperly or in a way that is in breach of our Terms of Service. Future Automation provides warranty for the mechanism you purchased for the period of 24 months from the date of purchase, provided that it isn’t used for unintended purposes. Under the warranty, Future Automation aims to either solve the issue remotely (via telephone or email support) or if the mechanism requires a part, arrange a visit to your premises by a Future Automation approved engineer or send replacement items where appropriate. Warranty repairs will be carried out as quickly as possible, but subject to parts availability. This warranty period is respectively extended for the period of a repair. A malfunctioning product must be cleaned and placed into suitable packaging to protect against transit damage before organising delivery to a repair workshop. All the complaints about defects must be submitted to the vendor/installer that sold this product, rather than directly to the manufacturer. Any part of your system that needs to be replaced during a warranty repair becomes the property of Future Automation. The warranty does not cover the following: • Damages resulting from improper product use or maintenance. • Repairs carried out by unauthorized persons. • Natural wear and tear during operation. • Damages caused by the buyer. • Accidental damages caused by a customer or damages caused as a result of careless attitude or usage, or damages caused by natural disasters (natural phenomena). • Any electrical, or other environmental work external to your Future Automation mechanism including power cuts, surges etc. • Additional items not supplied by Future Automation although they may have been supplied together by the retailer • Any 3rd party software products controlling your mechanism • Any transfer of ownership. Warranty is provided only to the initial purchaser. • Compensation for loss of use of the product, and consequential loss of any kind. A separate Safety and Servicing Information document is provided with these instructions (additional copies can be found at www.futureautomation.co.uk/safety), and this document MUST be filled out by the approved Future Automation Dealer who is installing the product. This Warranty Sheet must be held by the end user for the duration of the products life and will be referred to during servicing or warranty queries. The Safety and Servicing Information document also contains two Service History Forms that must be filled in by the approved Future Automation dealer who is performing the first required yearly service of this product. One copy of the Service History Form must be held by the customer (along with the Warranty Sheet) and a duplicate copy must be held by the approved Future Automation dealer that performed the service. Missing and/or mismatching documents may delay or invalidate warranty claims. Additional Service History Forms can be found on the Future Automation website for further yearly services. RISK ASSESSMENT INFORMATION It is the installer’s responsibility to perform a risk assessment of installed products. Future Automation can provide guidelines to installers/dealer about what should be included in a risk assessment, but due to the individual nuances of each location/site, Future Automation cannot provide a full list of areas to risk assess. For full risk assessment and safety information please view our Safety and Servicing guide available at www.futureautomation.net/safety 2
Page 5
GUIDE CONTENTS SAFETY DISCLAIMER 1 PRODUCT WARRANTY & RISK ASSESSMENT 2 GUIDE CONTENTS 3 PACKAGE CONTENTS 4 MECHANISM QUICK-START GUIDE 5 INITIAL TESTING 6 WALL CUTOUT 7 IN-WALL INSTALLATION 8 IN-WALL INSTALLATION (CONT.) 9 PANEL FITTING 10 PANEL FITTING (CONT.) 11 PROJECTOR MOUNTING 12 PROJECTOR MOUNTING (CONT.) 13 SWITCH ADJUSTMENTS 14 GENERAL CONTROL 15 INFRARED (IR) 16 RADIO FREQUENCY (RF) 17 CONTACT CLOSURE 18 RS232 CONTROL 19 3
Page 6
PACKAGE CONTENTS 1 - PH2 1.1 - MAIN CARRIAGE 1.2 - INNER COVERS 1.3 - PROJECTOR MOUNT BARS 1.4 - DOOR PANEL MOUNT 2 - CONTROL BOARD 3 - INFRARED (IR) REMOTE CONTROL ITEMS NOT SHOWN ON PAGE PH2 ACCESSORY PACK: - X2 AAA BATTERIES - MULTIPACK OF NUTS, BOLTS AND WASHERS - MAINS POWER, IR AND CONTACT CLOSURE LEADS 1.2 1 1.2 3 1.3 1.3 2 1.4 4
Page 7
MECHANISM QUICK-START GUIDE Some Future Automation mechanisms may ship with the control box disconnected to prevent damage during transit. In order to operate the mechanism, the control box will need to reconnected, then have mains power applied along with the desired control method. RECONNECTING THE CONTROL BOX To reconnect the mechanism control box, follow the below steps: 1. Make sure the power is disconnected from the control box. 2. Remove the retaining screw and washer from the end of the control box to allow removal of the control box lid. (Image 1 Below). 3. Slide off the control box lid to reveal the control board inside. 4. Locate the green connector on the end of the loom leading from the lift mechanism. This plug will have a small tag attached stating the correct connecting socket on the control board (e.g. “AC1”, “DC2”...) (Image 2 Below). 5. Plug the green connector into the corresponding socket on the control board. This plug is handed and will only connect correctly one way. Do NOT force the connector into the socket, this can cause serious damage to the control board and mechanism. 6. Route the wiring loom out of the end of the control box by inserting the black plastic inserts into the slots provided. (Image 3 Below). 7. Slide the control box cover back over the control board and replace the fixing screw and washer. Image 1. Image 2. Image 3. Image 4. IMPORTANT For the mechanism to operate, the green three way safety connector with the loop of wire attached, must also be plugged into the end of the control box. (Image 4 above). If this connector is not plugged in, a bright red LED will be visible inside control board and the Input Confirmation Input LED will be permanently illuminated. 5
Page 8
INITIAL TESTING 1 • Unpack and check the mechanism fully for any damage or obvious visual faults before operation. 2 • Test the mechanism by running it between the fully OPEN and fully CLOSED positions (refer to the mechanism control section of the instructions for more details). WARNING: THE CT MECHANISM DOES NOT HAVE AN ANTI-JAM CAPABILITY. THE MOTOR DRIVE SYSTEM WILL CONTINUE TO MOVE UNTIL A LIMIT SWITCH IS CONTACTED. KEEP HANDS AND ANY OBJECTS CLEAR OF MECHANISM DURING OPERATION TO REDUCE RISK OF DAMAGE OR INJURY. 6
Page 9
WALL CUTOUT 1 • As the PH2 Mechanism has been design for in-wall fixing, it requires a void size of Width 800mm [31.5”] x Height 710mm [28.0”] x Depth 300mm [11.8”] + Front Panel Thickness. • It is strongly recommended that a supporting structure is attached to all four faces of the Main Enclosure. 2 • Power and Signal cables will need to be run to the lower portion of the wall void for entry into the PH2 Mechanism. 800 [31.5] Back Joist 710 Framework [28.0] Front Panel 300 [11.8] + Panel Thickness 7
Page 10
IN-WALL INSTALLATION 1 • Using the Infrared (IR) Remote Control, open the PH2 mechanism to its fully OPEN position (refer to the mechanism control section of the instructions for more details). • Remove the Internal Covers from the PH2 Mechanism and keep them for installation later. • Power and Signal cables for the projector will need to be run through the mechanism’s cable entry/exit hole shown Internal Covers Cable Entry/Exit Holes below, prior to positioning the mechanism into the wall cavity. 2 • Insert the PH2 Mechanism into wall cavity in the orientation shown below. 8
Page 11
IN-WALL INSTALLATION (CONT.) 1 • The PH2 Mechanism should be secured into the wall cavity using suitable wall fixings (not supplied) through the 8 fixing holes indicated below. Fixing Holes • Once secured to the wall void, replace the internal covers removed in the previous stage. • Ensure enough slack has been left in the projector power and signal cables for the mechanism to open and close correctly once the projector has been installed. 2 • AfÏx the aperture cladding panel to the front of the PH2 mechanism. Dimensions for this cladding panel can be found on the PH2 Technical Specification Sheet. NOTE: This cladding should be removeable to allow access to the mechanism for servicing. Aperture Cladding Panel 9
Page 12
PANEL FITTING 1 • A decorative front panel can be attached to the PH mechanism to provide a clean finish when the mechanism is in the CLOSED position. • This can be mounted using the fixing hole indicated below, or by using the adhesive pads provided. Adhesive Pads Decorative Panel Fixing Holes 2 • Position the decorative panel so that it has an even 5mm [0.2”] gap all around. This gap is required to allow clearance when the mechanism is in movement. 5mm [0.2”] Shadow Gap Required 10
Page 13
PANEL FITTING (CONT.) 1 • To fix the decorative panel using the fixing holes, the mechanism will need to be in the OPEN position. • The internal fixing panel can be detached by removing the four side lock bolts as shown. 2 • Once the locking bolts have been removed, the internal fixing panel can be unhooked and removed. • The decorative panel can be attached using the hole and slots on the fixing panel. 11
Page 14
PROJECTOR MOUNTING 1 • With the mechanism in the OPEN position and the Internal Fixing Panel removed, the Projector Mount Bars can be removed by release the 4 nuts that hold them from underneath. 2 • The projector mount bars should be secured to the projectors mount holes using suitable fixings. • The projector Mount Bars are slotted to cater for most common projectors. 12
Page 15
PROJECTOR MOUNTING (CONT.) 1 • Place the Projector Mount Bars (with projector attached) back into the PH2 mechanism. Adjust the projector forwards and back to allow even clearance all round inside the PH2 mechanism. 2 • Secure the Projector Mount Bars in place by replacing the four securing bolts and replace the Internal Fixing Panel. Secure the Internal Fixing Panel in place with the 4 side locking bolts. 3 • Attach the projector power and source cables, making sure to leave enough slack to allow safe movement between the mechanisms OPEN and CLOSED positions. 13
Page 16
SWITCH ADJUSTMENTS 1 • The PH2 mechanism will be factory supplied with the CLOSED position set to 0°. If this needs adjusting, the CLOSED limit switch is located at the top of the mechanism as shown. • To adjust the position of this switch, loosen the two nuts that hold the switch in place and slide the switch forwards or backwards as required. 2 • The PH2 mechanism will be factory supplied with the OPEN position set to 90°. If this needs adjusting, the OPEN limit switch is located at the bottom of the mechanism as shown. • To adjust the position of this switch, loosen the two nuts that hold the switch in place and slide the switch up or down as required. 14
Page 17
GENERAL CONTROL This mechanism has multiple standard control methods, each of which requires a different input method to the control box. For ease, the input sockets on the control board are labelled below. (Control box size and style may vary to image shown) Mains Voltage Input CONTROL BOX INPUTS RS232 (RJ11/RJ25) Contact Closure (RJ45) Input Confirmation LED Emergency Stop Connector IR Input Jack (3.5mm) MECHANISM EMERGENCY STOP CONNECTOR This mechanism features an Emergency Stop Connector, which MUST be plugged into the control box in the connector labelled above for the mechanism to operate. If this connector is not plugged in, the Input Confirmation LED will be permanently lit. As per the red plastic tag attached to the Emergency Stop Connector (and shown below), the small loop of wire in this connector is designed to be replaced by a third party safety mechanism. REPLACING MECHANISM BATTERIES The standard Future Automation Infrared (IR) remote control required x2 AAA batteries to operate. These are provided with the mechanism in the Accessories Pack. These batteries can be replaced as the per the image below. 15
Page 18
INFRARED (IR) This mechanism can be controlled via the supplied 14 button Infrared (IR) Remote Control, paired with the supplied Infrared (IR) lead and sensor. The mechanism's functions can be controlled by plugging the Infrared (IR) lead and sensor into the 3.5mm IR Input Jack shown on the General Mechanism Control page. Confirmation of Infrared (IR) input will be shown by a single flash of the large green LED located on the end of the control box. As Infrared (IR) control works over line of site, the Infrared (IR) sensor must be directly viewable from what ever location the remote control is being used from. Infrared (IR) Remote Control Button Layout IN - Brings the mechanism into the cabinet. OUT - Brings the mechanism out of the cabinet, without swivelling. STOP - Will stop the operation of the mechanism at ANY position. IMPORTANT Only buttons indicated above are functional with the product. Any other button press will STOP the mechanism. 16
Page 19
RADIO FREQUENCY (RF) If purchased with the Radio Frequency (RF) control option, this mechanism can be controlled via the supplied 4 button Radio Frequency (RF) Remote Control, paired with the in-built Radio Frequency (RF) sensor. Confirmation of Radio Frequency (RF) input will be shown by a single flash of the large green LED located on the end of the control box. Radio Frequency (RF) control does not require line of site, but signal can affected cabinet thickness, cabinet material or other electronic signals (i.e. strong WIFI signals). Radio Frequency (RF) Remote Control Button Layout IN - Brings the mechanism into OUT - Brings the mechanism the cabinet. out of the cabinet, without swivelling. STOP - Will stop the operation of STOP - Will stop the operation of the mechanism at ANY position. the mechanism at ANY position. The Radio Frequency (RF) Remote Control can only be used to recall the above functions. The mechanism limits and preset positions must be programmed using the supplied Infrared (IR) Remote Control. IMPORTANT Pressing any button while the mechanism is moving will STOP the mechanism. 17
Page 20
CONTACT CLOSURE This Mechanism can be controlled via Contact Closure, utilising an 8 Pin RJ45 Connector attached to a length of CAT5 (Type 568A or 568B) cable. The mechanism’s functions can be controlled by plugging this into the RJ45 port on the mechanism control board, then shorting pins 1-8 on this connector as shown in the Contact Closure Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box, as well as illumination of the corresponding Contact Closure LED on the printed circuit board as shown below. RJ45 PIN LAYOUT CONTACT CLOSURE LED LAYOUT LED 1 LED 2 LED 3 LED 4 LED 5 (NOT USED) Contact Closure Input Port CONTACT CLOSURE INPUT TABLE WIRE/CABLE TYPE PIN DESCRIPTION ACTION LED 568A 568B INDICATOR 1 12V SUPPLY 12V SUPPLY - CURRENT LIMITED W W G O 2 12V LATCH WHEN 12V ATTACHED, DEVICE WILL MOVE TO PRESET G O POSITION. WHEN 12V REMOVED, DEVICE WILL GO IN. 3 GROUND GROUND W O W G 4 DEVICE LATCH (OUT) SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO OUT B B POSITION, WHEN REMOVED DEVICE WILL MOVE TO IN POSITION. 5 DEVICE LATCH (PRE- SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO PRESET W W LED 4 SET) POSITION, WHEN REMOVED DEVICE WILL MOVE TO IN POSITION. B B 6 DEVICE STOP MOMENTARY SHORT TO GROUND (PIN 3), STOPS DEVICE IN O G LED 3 CURRENT POSITION. 7 DEVICE OUT MOMENTARY SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO W W LED 2 OUT POSITION. BR BR 8 DEVICE IN MOMENTARY SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO IN BR BR LED 1 POSITION. 18
Page 21
RS232 CONTROL This Mechanism can be controlled via RS232, utilising a 6 Pin RJ11/RJ25 connector OR 9 Pin Serial connector attached to a length of 6 core cable. The mechanism's functions can be controlled by plugging this into the RJ11/RJ25 port on the mechanism control box, then inputting the RS232 commands shown in the RS232 Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box. RJ11/RJ25 PIN LAYOUT SERIAL PIN LAYOUT PIN 1: TX PIN 2: RX PIN 6: RX PIN 3: TX PIN 3 & 4: GROUND PIN 5: GROUND RS232 PROGRAMMING DETAILS RJ11/RJ25RJ11/RJ25 Func.Func. 9 PIN Serial9 PIN Serial ColourColour Baud Rate: 9600 PIN 1PIN 1 TX-RXTX-RX PIN 2PIN 2 Blue Stop Bit: 1 PIN 3PIN 3 GROUNDGROUND PIN 5PIN 5 Green Parity: None PIN 4PIN 4 GROUNDGROUND PIN 5PIN 5 Red Databits: 8 PIN 6PIN 6 RX-TXRX-TX PIN 3PIN 3 WhiteWhite RS232 INPUT TABLE IMPORTANT - Ensure all protocols are entered exactly as written below, including Carriage Return (ENTER / ASCII 13) Protocol Action fa_in Carriage Return (Enter / ASCII 13) Device IN fa_out Carriage Return (Enter / ASCII 13) Device OUT fa_stop Carriage Return (Enter / ASCII 13) Device STOP (At any position) 19
Page 22
NOTES:
Page 23
NOTES:
Page 24
EUROPEAN OFFICE NORTH AMERICAN OFFICE Address: Address: Unit 6-8 Enterprise Park Brunel Road 127 Venture Drive Bedford Dover Bedfordshire NH MK41 9TG 03820 Phone: +44 (0) 1438 833577 Phone: +1 (603) 742 9181 Email: info@futureautomation.co.uk Email: info@futureautomation.net OfÏce Hours: OfÏce Hours: Mon - Fri 8:00 to 17:30 GMT Mon - Fri 7:00 to 17:00 EST Saturday & Sunday - Closed Saturday & Sunday - Closed www.FUTUREAUTOMATION.net