Page 1

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP SPECIFICATION MEASUREMENTS Maximum Screen Height 730mm (28 3/4") Maximum Lifting Capacity 50Kg (110lb) Maximum Lifting Capacity (Marine) 30Kg (66lb) Internal Cabinet Height 880mm (34 5/8") Decibel Rating 52 dB Packaging Dimensions 1080 x 850 x 330mm (42 1/2 x 33 7/16 x 13") Shipping Weight 35Kg (77lb) Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption 250 - 500W Power Consumption Standby 3W Mounting Patterns Supported VESA 400, 300, 200 W x 400, 300, 200 H Control Options IR Remote, RS232, Contact Closure, RF Available Product Options / Features Specific B&O and Loewe mounts / adapters, Custom RAL paint finishes Package Contents Mechanism, IR remote control, Push Flap Kit, Box Enclosure Kit Marine Suitable Yes TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP 1 5/16" 33 CABLE ROUTING Maximum Possible Depth of Conduit The LSM has an easily removable Mount Cover that cables from the screen can be routed underneath. Cables then travel through the centre of the Mount Boss and into the beam. Cables must be routed carefully to prevent any interference with the LSM beam as it operates. Screen and Mechanism cables should be routed TOP VIEW to a control box outside of the cabinet via an opening in the back of the cabinet or a conduit leading to the bottom. SCREEN CABLES MECHANISM CABLES POWER CABLE P P AB To Mains Power DETAIL AB TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP LSM-BE 5 - MECHANISM UP - IN CABINET Aperture Depth = Screen Depth + 83 [3 1/4"] (Minimum 121 [4 3/4"]) 1/8" 13/16" 3 20 Base Panel to Minimum Distance Cabinet aperture from Screen to inside of Cabinet SECTION C-C 1 13/16" 46 13/16" 20 B C C Box Enclosure 28 3/4" 29 3/4" 730 Internal Width = 755 DETAIL D Max Screen Width Internal Box Screen + 40mm [1 9/16"] Enclosure Height Height 4 9/16" 13/16" 116 20 D Back of Mechanism Max Thickness to Back of Mount of Base and Cabinet Top 34 5/8" 880 Internal Cabinet Height 6 1/16" B 154 Internal Cabinet Width = SECTION B-B Screen Width + 100 [3 15/16"] Minimum Width = 850 [33 7/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 4 FUTUREAUTOMATION

Page 5

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP LSM-BE 5 - MECHANISM DOWN - IN CABINET Shown with tapered Box Enclosure Lid in square Cabinet Aperture. Aperture Depth = A tapered Cabinet Aperture can be Screen Depth + 83 [3 1/4] used to improve the fit. (Minimum 121 [4 3/4]) Aperture Width = Screen Width +86mm [3 3/8"] 13/16" 20 DETAIL F Maximum Thickness of Base and Cabinet Top E F 3/8" 10 Minimum Distance between Box Enclosure and Cabinet 28 3/4" 29 3/4" 730 755 34 5/8" Max Internal Box 880 Screen 5 3/4" Enclosure Internal 145 Height Height Cabinet Minimum Screen Height Height from Base of Cabinet 6 7/16" 164 SECTION E-E E TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 5 FUTUREAUTOMATION

Page 6

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP BOX ENCLOSURE BASE PANEL AND LID DETAILS NOTE: A tapered Box Enclosure Lid creates a good fit in the Cabinet Aperture and helps the Box Enclosure to BOX ENCLOSURE LID (TAPERED) TOP VIEW locate within the cabinet. Lid Depth = Cabinet Aperture Depth Depth -2mm [1/16"] Box Enclosure Lid Width = Cabinet Aperture Width -2mm [1/16"] 3 1/8" 3 1/16" 2 9/16" 2 1/4" BASE PANEL TOP VIEW 80 65 57 78 Base Panel Depth = Cabinet Aperture Depth -6mm [1/4"] (Minimum 115mm [4 1/2"]) 1 3/4" 4 5/16" 1/2" Viewing Side 45 110 12 Base Panel Width = Cabinet Aperture Width - 6mm [1/4"] 3 1/16" 6 7/8" BASE PANEL BOTTOM VIEW 3/8" 78 175 10 Viewing Side G

SECTION G-G 3/8" G R10 32 1 1/4"

TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 6 FUTUREAUTOMATION

Page 7

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP LSM-PF 5 - MECHANISM UP - IN CABINET Aperture Depth = Screen Depth + 83 [3 1/4"] (Minimum 121 [4 3/4"]) 13/16" 1/8" 20 3 Minimum Distance Base Panel to SECTION I-I from Screen to inside of aperture Cabinet aperture 1 13/16" 46 H I I 28 3/4" 730 Max Screen 4 9/16" Height 116 DETAIL J 13/16" 20 J Max Thickness of Base and Cabinet Top 34 5/8" 880 Internal Cabinet Height 6 1/16" 154 H SECTION H-H Internal Cabinet Width = Screen Width + 60 [2 3/8"] Minimum Width = 850 [33 7/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 7 FUTUREAUTOMATION

Page 8

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP 1/8" LSM-PF 5 - MECHANISM DOWN - IN CABINET 3 Rebate Aperture Depth Maintain Shadow Gap Aperture Depth = Aperture Width = Screen Width +46mm [1 13/16"] Screen Depth + 83 [3 1/4"] (Minimum 121 [4 3/4"]) 3/16" 5 Recommended Rebate Width 1/8" 3 Flap to Cabinet Aperture Aperture Depth DETAIL N K N 13/16" 20 Maximum Thickness of Base and Cabinet Top 28 3/4" 730 34 5/8" Maximum 880 Screen Height Internal Cabinet 5 11/16" Height 145 Minimum Screen Height from Base of Cabinet SECTION K-K TECHNICAL SHEET K UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 8 FUTUREAUTOMATION

Page 9

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP A step is required on the front of PUSH FLAP BASE PANEL AND FLAP DETAILS the flap to meet a step in the Flap depth dimensions are based on a 3mm thick piano hinge front edge of the cabinet aperture Required flap dimensions may vary dependant on the hinge used FLAP PANEL - BOTTOM VIEW M L DETAIL M Flap Panel Depth = Rebate Aperture Depth Aperture Depth -6mm [1/4"] -6mm[1/4"] (Minimum 120mm [4 3/4"]) 13/16" L 20 Flap Panel Width = Cabinet Aperture Width -6mm [1/4"] SECTION L-L 3 1/8" BASE PANEL - TOP VIEW 3 1/16" 1/2" 80 1 5/8" 1 5/16" 78 12 42 34 Base Depth = Aperture Depth -29mm [1 1/8"] (Minimum 92mm [3 5/8"]) 13/16" 20 Viewing Side 4 5/16" 1 3/4" 110 45 BASE PANEL - BOTTOM VIEW 6 13/16" 173 3/8" N 10 Viewing Side 3 1/16" 78

SECTION N-N 9 3/8" 3/8" N R10

TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 9 FUTUREAUTOMATION

Page 10

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP BOX ENCLOSURE POSITION ADJUSTMENT The countersink bolts enable fine tuning the position of the box enclosure relative to the uprights AU 19 11/16" 500 Recommended Service Panel Aperture Width 1 7/16" 5mm Adjustment N 36 O 1" 26 1 7/16" 36 Required distance between top of aperture and bottom of lid DETAIL O SECTION N-N N TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 10 FUTUREAUTOMATION

Page 11

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP SCREEN MOUNT ADJUSTABILITY A standard adjustable height VESA 400 mount is included. This is also compatible with VESA 300 and 200 mounting patterns 15 3/4" Separate VESA 300 and 200 mounts are available. 400 11 13/16" 300 7 7/8" 200 10 7/16" 15 3/4" 265 C L 400 Lowest Possible V400 Centreline of Mount 18 5/16" C 15 3/4" 465 L 400 Highest Possible Centreline of Mount V300 V200 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 11 FUTUREAUTOMATION

Page 12

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP MECHANISM INSTALLTION OVERVIEW The Flap Panel is attached Box Enclosure Top to a hinge at the back of the cabinet aperture. Box Enclosure Top Support Box Enclosure Back Cover The LSM is fixed to the back of the cabinet with wood screws. Box Enclosure Back Section Box Enclosure Base Screen mount easily removed with concealed bolts Screen mount must be removed for installation of Base Panel The LSM is fixed to the back of the cabinet with wood screws. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 12 FUTUREAUTOMATION

Page 13

LSM-BE/PF 5 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP OVERALL MECHANISM DIMENSIONS MECHANISM - UP POSITION MECHANISM - DOWN POSITION 34 9/16" 878 34 5/8" Back 880 Tray Height 31 5/16" 19 3/4" 6 1/16" 6 7/16" 795 501 154 164 22 5/16" 568 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 013 WWW NET . . SHEET 13 FUTUREAUTOMATION