LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP SPECIFICATION MEASUREMENTS Maximum Screen Height 545mm (21 7/16") Maximum Lifting Capacity 50Kg (110lb) Maximum Lifting Capacity (Marine) 30Kg (66lb) Internal Cabinet Height 694mm (27 5/16") Decibel Rating 52 dB Packaging Dimensions 955 x 850 x 330mm (37 5/8" x 33 7/16 x 13") Shipping Weight 35Kg (77lb) Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption 250 - 500W Power Consumption Standby 3W Mounting Patterns Supported VESA 400, 300, 200 W x 400, 300, 200 H Control Options IR Remote, RS232, Contact Closure, RF Available Product Options / Features Specific B&O and Loewe mounts / adapters, Custom RAL paint finishes Package Contents Mechanism, IR remote control, Push Flap Kit, Box Enclosure Kit Marine Suitable Yes TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP 1 1/2" 38 CABLE ROUTING Maximum Possible Depth of Conduit The LSM has an easily removable Mount Cover that cables from the screen can be routed underneath. Cables then travel through the centre of the Mount Boss and into the beam. Cables must be routed carefully to prevent any interference with the LSM beam as it operates. Screen and Mechanism cables should be routed to a control box outside of the cabinet via an TOP VIEW opening in the back of the cabinet or a conduit leading to the bottom. SCREEN CABLES MECHANISM CABLES POWER CABLE P P A To Mains Power DETAIL A TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP Aperture Depth = Screen Depth + 83 [3 1/4"] LSM-BE 2 - MECHANISM UP - IN CABINET (Minimum 121 [4 3/4"]) 1/8" 13/16" 3 20 Minimum Distance 1 13/16" from Screen to inside of Cabinet SECTION C-C 46 4 9/16" 116 13/16" Back of Mechanism 20 to Back of Mount B C C Box Enclosure Internal Width = 22 3/8" Screen Width DETAIL D 569 + 40mm [1 9/16"] Internal Box 545 Enclosure 21 7/16" Height Max Screen height 13/16" 20 D Max Thickness 27 5/16" of Base and 694 Cabinet Top Internal Cabinet Height 6 1/16" 154 B SECTION B-B Internal Cabinet Width = Screen Width + 100 [3 15/16"] Minimum Width = 850 [33 7/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP LSM-BE 2 - MECHANISM DOWN - IN CABINET Shown with tapered Box Enclosure Lid in square Cabinet Aperture. A tapered Cabinet Aperture can be Aperture Depth = used to improve the fit. Screen Depth + 83 [3 1/4] (Minimum 121 [4 3/4]) Aperture Width = Screen Width +86mm [3 3/8"] 13/16" 20 Maximum Thickness of Base and E DETAIL F Cabinet Top 13/16" F 20 Minimum Distance between Box Enclosure and Cabinet 21 7/16" 22 3/8" 545 569 5 3/4" 27 5/16" Max 145 Internal Box 694 Screen Minimum Screen Enclosure Internal Height Height from Base Height Cabinet of Cabinet Height 6 7/16" 164 SECTION E-E E TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 5 FUTUREAUTOMATION
Page 6
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP NOTE: A tapered Box Enclosure Lid creates a good fit in the Cabinet Aperture and helps the Box Enclosure to locate within the cabinet. BOX ENCLOSURE BASE PANEL AND LID DETAILS BOX ENCLOSURE LID (TAPERED) TOP VIEW Lid Depth = Cabinet Aperture Depth Depth -2mm [1/16"] Box Enclosure Lid Width = Cabinet Aperture Width -2mm [1/16"] 3 1/8" 3 1/16" 2 9/16" 2 1/4" 80 65 BASE PANEL TOP VIEW 57 78 Base Panel Depth = Cabinet Aperture Depth -6mm [1/4"] (Minimum 115mm [4 1/2"]) 1 3/4" 4 5/16" 1/2" Viewing Side 45 110 12 Base Panel Width = Cabinet Aperture Width - 6mm [1/4"] 3 1/16" BASE PANEL BOTTOM VIEW 6 7/8" 3/8" 78 175 10 Viewing Side G SECTION G-G
3/8" G R10 32 1 1/4"
TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 6 FUTUREAUTOMATION
Page 7
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP Aperture Depth = LSM-PF 2 - MECHANISM UP - IN CABINET Screen Depth + 83 [3 1/4"] (Minimum 121 [4 3/4"]) 13/16" 20 1/8" 3 Minimum Distance Base Panel to from Screen to inside of aperture SECTION I-I 1 13/16" Cabinet aperture 46 H I I 21 7/16" 545 Max Screen J Height DETAIL J 4 9/16" 13/16" 116 20 Back of Max Thickness Mechanism 27 5/16" of Base and 694 to Mount Cabinet Top Internal Cabinet Height 6 1/16" 154 H SECTION H-H Internal Cabinet Width = Screen Width + 60 [2 3/8"] Minimum Width = 850 [33 7/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 7 FUTUREAUTOMATION
Page 8
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP Rebate Aperture Depth LSM-PF 2 - MECHANISM DOWN - IN CABINET Aperture Depth 1/8" Aperture Width = Screen Width +46mm [1 13/16"] 3 DETAIL L Maintain Shadow Gap 1/8" 3 Flap to Cabinet 3/16" Aperture 5 Aperture Depth = Recommended Screen Depth + 83 [3 1/4"] 13/16" Rebate Width (Minimum 121 [4 3/4"]) 20 Maximum Thickness of Base and K Cabinet Top L 21 7/16" 545 27 5/16" Maximum 694 5 11/16" Screen Height Internal 144 Cabinet Minimum Screen Height Height from Base of Cabinet SECTION K-K TECHNICAL SHEET K UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 8 FUTUREAUTOMATION
Page 9
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP A step is required on the front of PUSH FLAP BASE PANEL AND FLAP DETAILS the flap to meet a step in the DETAIL M front edge of the cabinet aperture Flap depth dimensions are based on a 3mm thick piano hinge. Required flap dimensions may vary dependant on the hinge used. FLAP PANEL - BOTTOM VIEW M O Flap Panel Depth = Rebate Aperture Depth Aperture Depth -6mm [1/4"] -6mm[1/4"] (Minimum 120mm [4 3/4"]) 13/16" O 20 Flap Panel Width = Cabinet Aperture Width -6mm [1/4"] SECTION O-O 3 1/8" 3 1/16" BASE PANEL - TOP VIEW 1/2" 80 1 5/8" 1 5/16" 78 12 42 34 Base Depth = Aperture Depth -29mm [1 1/8"] (Minimum 92mm [3 5/8"]) 13/16" 20 4 5/16" 1 3/4" Viewing Side 110 45 6 13/16" BASE PANEL - BOTTOM VIEW 173 3/8" N 10 Viewing Side 3 1/16" 78
SECTION N-N 3/8" 9 3/8" N R10
TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 9 FUTUREAUTOMATION
Page 10
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP BOX ENCLOSURE POSITION ADJUSTMENT The countersink bolts enable fine tuning the position of the box AU enclosure relative to the uprights 19 11/16" 500 Recommended Service 5mm Adjustment Panel Aperture Width 1 7/16" P 36 Q 1" 26 1 7/16" 36 Required distance between top of aperture and bottom of lid DETAIL Q SECTION P-P P TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 10 FUTUREAUTOMATION
Page 11
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP SCREEN MOUNT ADJUSTABILITY A standard adjustable height VESA 400 mount is included. This is also compatible with VESA 300 and 200 mounting patterns Separate VESA 300 and 200 mounts are available. 11 13/16" 11 13/16" 300 300 7 7/8" 7 7/8" 200 200 12 1/2" 318 8 9/16" Highest Possible 218 Centreline of Mount Lowest Possible Centreline of Mount
C V400 L C L 370 14 9/16"
V300 V200 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 11 FUTUREAUTOMATION
Page 12
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP MECHANISM INSTALLATION OVERVIEW Box Enclosure Top The Flap Panel is attached to a hinge at the back of the Box Enclosure Top Support cabinet aperture. Box Enclosure Back Cover The LSM is fixed to the back of the cabinet with wood screws. Box Enclosure Back Section Box Enclosure Base Screen mount must be removed for installation of Base Panel Screen mount easily removed with concealed bolts The LSM is fixed to the back of the cabinet with wood screws. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 12 FUTUREAUTOMATION
Page 13
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP OVERALL MECHANISM DIMENSIONS MECHANISM - UP POSITION MECHANISM - DOWN POSITION 27 1/4" 692 27 5/16" Back 694 Tray Height 31 5/16" 19 3/4" 6 1/16" 6 7/16" 795 501 154 164 22 5/16" 568 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 13 FUTUREAUTOMATION
Page 14
LSM-BE/PF 2 LIFT SYSTEM FOR BOX ENCLOSURE/ PUSH FLAP CONTROL BOX DIMENSIONS
207
20 max. 13/16" max.
RS232 PORT CONTACT CLOSURE PORT
1/4" IR OUTPUT 52 7 INDICATOR LED 2 1/16"
EMERGENCY STOP CONNECTOR
IR LEAD INPUT 8 5 5/16" 3/16" 3.5mm [1/8"] JACK
5 7/8" 150 NOTES CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"] CONTROL BOX MUST BE LOCATED IN ACCESSIBLE LOCATION TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 014 WWW NET . . SHEET 14 FUTUREAUTOMATION