product specifications 369547d 10.27.15 Remote Power Modules Remote Power Modules (RPMs) are used to control lighting, motor, and fan loads. There are several different models of RPMs. Each model controls specific load types. The RPMs are mounted in remote power panels. All RPMs must be connected to a module interface housed within the same panel enclosure. RPMs within an enclosure are connected to the module interface using a Lutron-provided harness. To minimize the effects of single power supply failure, each RPM is powered by its own internal power supply. Model Numbers Model Voltage Description HW-RPM-4A-120 120 V~ Adaptive Dimming Module HW-RPM-4A-230 220–240 V~ Adaptive Dimming Module HW-RPM-4E-230-CE 220–240 V~ ELV Dimming Module HW-RPM-4FSQ-120 120 V~ Quiet Fan Speed Control Module HW-RPM-4J-120 120 V~ Adaptive Dimming Module HW-RPM-4M-120 120 V~ Motor Control Module HW-RPM-4M-230 220–240 V~ Motor Control Module HW-RPM-4R 100–277 V~ Power Relay Module HW-RPM-4U-120 120 V~ Dimming Module HW-RPM-4U-230-CE 220–240 V~ Dimming Module HW-RPM-4U-240 240 V~ Dimming Module www.lutron.com 1 Technical support: U.S.A.: 800.523.9466 Europe: +44.(0)20.7680.4481
Page 2
product specifications 369547d 10.27.15 Remote Power Modules Specifications Model Numbers HW-RPM-4A-120, HW-RPM-4A-230, HW-RPM-4E-230-CE, HW-RPM-4FSQ-120, HW-RPM-4J-120, HW-RPM-4M-120, HW-RPM-4M-230, HW-RPM-4R, HW-RPM-4U-120, HW-RPM-4U-230-CE, HW-RPM-4U-240 Power • HW-RPM-4A-120, HW-RPM-4FSQ-120, HW-RPM-4J-120, HW-RPM-4M-120, HW-RPM-4U-120: 120 V~ 50 / 60 Hz • HW-RPM-4A-230, HW-RPM-4M-230, HW-RPM-4U-230-CE, HW-RPM-4U-240: 220–240 V~ 50 / 60 Hz • HW-RPM-4R: 100–277 V~ 50 / 60 Hz Number of Outputs 4 Regulatory Approvals UL®, CSA, NOM Environment Ambient operating temperature : 32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity, non-condensing. Indoor use only. Cooling Passive cooling. Heat Generated • HW-RPM-4A-120, HW-RPM-4A-230, HW-RPM-4E-230-CE, HW-RPM-4J-120: 90 BTUs per hour. Fully Loaded • HW-RPM-4FSQ-120, HW-RPM-4M-120, HW-RPM-4M-230, HW-RPM-4R: 18 BTUs per hour. • HW-RPM-4U-120, HW-RPM-4U-230-CE, HW-RPM-4U-240: 70 BTUs per hour. Line-Voltage Separate line-voltage feeds at the DIN rail terminal blocks for each RPM. Terminal blocks should be Connections tightened to 3.5 in-lb to 5.0 in-lb (0.40 N•m to 0.57 N•m). Low-Voltage Communication harness (included). Communications 2 2 Wiring Terminal blocks will accept one 18 AWG to 10 AWG (1.0 mm to 6.0 mm ) wire or two 2 2 18 AWG to 16 AWG (1.0 mm to 1.5 mm ) wires. • HW-RPM-4M-120, HW-RPM-4M-230, HW-RPM-4R: Require the installation of four additional gray terminal blocks (included) and three additional black terminal blocks (included) to be mounted on to the DIN rail assembly. • HW-RPM-4R gray terminal blocks accept one 18 AWG to 8 AWG (1.0 mm2 2 to 10 mm ) wire or two 2 2 16 AWG to 12 AWG (1.5 mm to 4.0 mm ) wires. Addressing Manual rotary switch. Counts as 1 of 8 RPM addresses per module interface. Diagnostics LED provided to indicate proper communications with module interface. ESD Protection Meets or exceeds the IEC 61000-4-2 standard. Surge Protection Meets or exceeds ANSI/IEEE standard c62.41. Air Gap • HW-RPM-4U-120, HW-RPM-4U-230-CE HW-RPM-4A-120, HW-RPM-4A-230, HW-RPM-4J-120, HW-4FSQ-120, HW-RPM-4M-230: Provided when all four circuits are off. • HW-RPM-4R: Individual output airgap provided when each circuit is off. Fail-Safe Operation Rotary switch on the RPM allows for manual operation of each load. 7 Dimensions 3 ⁄8 in (99 mm) wide × 7 in (178 mm) high Lamp Buzz Lamp debuzzing coils (Lutron® model HW-HIFC-10-2, LDC-10-TCP, LDC-16-TCP) are available from Lutron to reduce lamp filament buzzing. Interface Suppression EMI/RFI suppression circuitry Warranty www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf www.lutron.com/TechnicalDocumentLibrary/Intl_Warranty.pdf www.lutron.com 2 Technical support: U.S.A.: 800.523.9466 Europe: +44.(0)20.7680.4481
Page 3
product specifications 369547d 10.27.15 Remote Power Modules Load Type, Rating, and Capacity Model Voltage/ Load Types1 Minimum Maximum Load Per: Maximum Technology Frequency Load Output Module BTUs / Hour 120 V~ INC, MLV, ELV, 10 W 10 A 16 A HW-RPM-4A-120 50/60 Hz NCC, F2W 2 LED See note 2 220–240 V~ INC, MLV, ELV, 10 W 8 A 13 A HW-RPM-4A-230 50/60 Hz NCC 2 90 RTISS-TE 6 LED See note 2 TM 220–240 V~ 3 HW-RPM-4E-230-CE 50/60 Hz INC, ELV 10 W 10 A 16 A 120 V~ INC, MLV, ELV, 10 W 6 A 16 A HW-RPM-4J-120 50/60 Hz NCC, F2W 2 LED See note 2 120 V~ 4 Quiet control HW-RPM-4FSQ-120 50/60 Hz Fan Motor 0.25 A 2 A 8 A circuitry 120 V~ INC 0 A 3 A HW-RPM-4M-120 50/60 Hz Motor 5 A (1/4 HP) 16 A (Bi-directional) Mechanical INC 0 A 1.5 A 18 interlocked 220–240 V~ relays HW-RPM-4M-230 50/60 Hz Motor 5 A (1/4 HP) 16 A (Bi-directional) 100–277 V~ Lighting 0 A 16 A 7 HW-RPM-4R 50/60 Hz Motor (1/3 HP) 64 A Softswitch® 5 5 120 V~ INC , MLV , 25 W 16 A 16 A HW-RPM-4U-120 50/60 Hz NCC, F2W, SFL 2 LED See note 2 220–240 V~ INC, MLV, 40 W 10 A 13 A RTISS HW-RPM-4U-230-CE 50/60 Hz NCC, SFL 70 Equipped®8 2 LED See note 2 220–240 V~ INC, MLV, 40 W 16 A 16 A HW-RPM-4U-240 50/60 Hz NCC,SFL 2 LED See note 2 1 For higher wattages or for load types other than those listed, a power booster or interface is required. For more details, refer to the HomeWorks® software. 2 NOTICE: To avoid the risk of equipment damage and for specific LED lamp / fixture compatibility, refer to the LED Product Selection tool at www.lutron.com/ledtool. For general information about minimum/maximum load requirements and LED loads refer to Application Note #487 - Minimum and Maximum loads for LED and CFL lamps / fixtures. Please note that LED is not currently a supported load type of UL® 508. As a result, this UL® listing does not guarantee compatibility between the remote power module and connected LED loads. 3 Only use with ELV transformers. If used with MLV transformers, the module may be damaged and the warranty will be void. 4 Control up to 4 ceiling fans (1 per circuit). Do not use to control fans that have integrated fan speed controls (i.e., fan with a remote control). This module may hum or buzz when at medium-high fan setting. Do not connect to lighting loads. Damage to the module could result. 5 In rare cases, incandescent lamps and MLV transformers will “buzz” or “hum”. The HW-HIFC-10-2 filter choke assembly reduces this hum. The filter choke assembly can be installed in place of module 8 in an HWI-PNL-8 remote power panel. 6 RTISS-TETM: (Real-Time Illumination Stability System-Trailing Edge). Same as RTISS®, but operates on the trailing edge of the A/C sine wave. This allows for true instantaneous voltage compensation. 7 Softswitch®: Lutron® Softswitch® circuitry prevents the relay contacts from arcing. Even when fully loaded, the arc reduction extends a relay’s average rated life to more than 1,000,000 on/off cycles. 8 RTISS Equipped® (Real-Time Illumination Stability System). This Lutron® filter circuit technology compensates for incoming line-voltage variations, such as changes in Root Mean Square (RMS) voltage, frequency shifts, harmonics, and line noise. www.lutron.com 3 Technical support: U.S.A.: 800.523.9466 Europe: +44.(0)20.7680.4481
Page 4
product specifications 369547d 10.27.15 Remote Power Modules Dimensions For information on mounting an RPM ® panel, Measurements shown as: in (mm) within an existing LiteTouch please refer to the installation guide of the Dimming & Switching Ready 7 3 ⁄8 (99) Retrofit Subplate at www.lutron.com 7 (178) Mounting HWAP-2S, HWBP-2S HWI-PNL-5 HWI-PNL-8 (shown), HWAP-8D, HWBP-8D LiteTouch is a registered trademark of Savant. www.lutron.com 4 Technical support: U.S.A.: 800.523.9466 Europe: +44.(0)20.7680.4481
Page 5
product specifications 369547d 10.27.15 Remote Power Modules Wiring HW-RPM-4A-120, HW-RPM-4A-230, HW-RPM-4E-230-CE, HW-RPM-4FSQ-120, HW-RPM-4J-120, HW-RPM-4U-120, HW-RPM-4U-230-CE, HW-RPM-4U-240 Removable Bypass Jumpers DH1 Red 1 DH2 Red 2 DH3 Red 3 DH4 Red 4 120 V~ or 220–240 V~ Hot Black White Neutral from Distribution Panel N1 N2 N3 Rotary Address N4 Switch 4-Pin connector for Module Interface HW-RPM-4M-120, HW-RPM-4M-230 Assembly Harness Input 120–240 V~ from Distribution Panel (20 A) Input Neutral from Distribution Panel R1 Red 1 L1 Yellow 1 R2 Red 2 L2 Yellow 2 Raise Lower Raise Lower R3 Red 3 MML3 Yellow 3 R4 Red 4 L4 Yellow 4 H Black Rotary Address N White Switch N 4-Pin connector for N Module Interface Assembly Harness N N HW-RPM-4R Input 100–277 V~ from Distribution Panel SH1 Red 1 H1 Black 1 Control Power N1 Control Neutral SH2 Red 2 H2 Black 2 N2 Red 3 Input Neutral from Distribution Panel SH3 Black 3 H3 N3 Rotary Address SH4 Red 4 Switch H4 Black 4 4-Pin connector for N4 Module Interface Assembly Harness www.lutron.com 5 Technical support: U.S.A.: 800.523.9466 Europe: +44.(0)20.7680.4481
Page 6
product specifications 369547d 10.27.15 Remote Power Modules Address Switch Position Diagnostic LED Status HW-RPM-4A-120, HW-RPM-4A-230, HW-RPM-4A-120, HW-RPM-4A-230, HW-RPM-4E-230-CE, HW-RPM-4FSQ-120, HW-RPM-4E-230-CE, HW-RPM-4FSQ-120, HW-RPM-4J-120, HW-RPM-4R, HW-RPM-4J-120, HW-RPM-4R, HW-RPM-4U-120, HW-RPM-4U-230-CE, HW-RPM-4U-120, HW-RPM-4U-230-CE, HW-RPM-4U-240: HW-RPM-4U-240: Position Module Output/Purpose LED Status Possible Cause 0 All outputs OFF Off No power or defective module 1–8 Address for normal operation 1 blink per second Normal operation 9 A Not used (“Heartbeat”) 9 B Output 1 ON; Use for temporary lighting and 1 blink per 7 seconds Not communicating with zone testing (“Lighthouse”) processor: 9 C Output 2 ON; Use for temporary lighting and • Open control harness zone testing • Module set on invalid or 9 D Output 3 ON; Use for temporary lighting and diagnostic address zone testing • System not properly configured 9 E Output 4 ON; Use for temporary lighting and or addressed in HomeWorks® zone testing software 9 F All outputs ON; Use for temporary lighting and 4 blinks; pause; repeat Module in manual override zone testing 10 blinks per second Zone error on one or more outputs HW-RPM-4M, HW-RPM-4M-230: Zone Diagnostic LED Status Position Module Output/Purpose HW-RPM-4E-230-CE, HW-RPM-4A-120, 0 All relays OFF HW-RPM-4J-120, HW-RPM-4A-230 only: 1–8 Address for normal operation 9 A–D Not used: All outputs OFF Zone LED Status Load Status Description 9 E All raise relays ON; Use for directional motor Off OFF Normal; Load Off testing Continuously on ON Incandescent/electronic 9 F All lower relays ON; Use for directional motor dimming testing 1 blink per ON Magnetic dimming second Error Codes 1 1 blink; pause; OFF Load short circuit repeat 2 blinks; pause; OFF Inductive load2 repeat 3 3 blinks; pause; ON Full Shorted component repeat 1 4 blinks; pause; OFF Overload repeat 10 blinks per All outputs Multiple errors4 second OFF 1 Locate and repair fault. Cycle power to RPM. 2 Check software configuration. MLV load detected with ELV software setting. 3 Enlarged view of Address Switch Replace RPM. Internal device (FET) shorted. 4 Multiple errors exist on this output. The relay has opened to protect the modules and all 4 outputs will be off. www.lutron.com 6 Technical support: U.S.A.: 800.523.9466 Europe: +44.(0)20.7680.4481