Instruction Manual WLED75CV1 Wired Single Channel Constant Voltage Dimmer 2024 Version 2.2.0

Page 2

For programming system programming information: Wired system setup guide. For a general overview: Wired RAK application sheet. Contents 1WhatistheWLED75CV1? 2Loadings 3Installing the WLED75CV1 4Terminating the WK-CONNECT 5AddingtheWLED75CV1intoRasoftPro Appendix 1 - Wiring Examples A1.1 STAR Wiring A1.2 Radial Wiring 1WhatistheWLED75CV1? TheWLED75CV1isasingleChannelconstantvoltagedimmerusedinaRakoWired network. TheRJ11portontheWLED75CV1isusedtoconnecttotheRakoWirednetwork,ifitisnot connected to one of the RAK-LINKs RJ11 ports, a WK-CONNECT is required. 2Loadings Voltage (MAX) Wattage (MAX) 12VDC 75W 24VDC 150W WLED75CV1 Manual Version 2.2.0

Page 3

3Installing the WLED75CV1 Installation should only be carried out by a competent electrician. DONOTCONNECTDIRECTLYTOTHEMAINSSUPPLY. WLED75CV1modulesshouldbemountedinareasthatareadequatelyventilated, anddry. Modulesshouldbemountedvertically, with the terminals at the bottom, or horizontally. Whilethemodulesaredesignedtobemaintenance-free, they should be mounted in an accessible location should investigation or re-addressing of the units be necessary. Ensurethat the cable clamps are fitted tightly to secure the cables. Theunitinputvoltage is 12V or 24V DC, and the power supply must be adequately rated for the connected load. STEP1 Removethecoversandcableclamps. STEP2 Connect the 12/24V DC power supply to the ‘DC Input’ terminals. Connect the 12/24V load to the ‘Output’ terminals. NB Theconnectedpowersupplymustbe adequately rated for the load. WLED75CV1 Manual Version 2.2.0

Page 4

STEP3 Connect the RJ11 cable to the RJ11 port. If the WK-CONNECT is used, connect the opposite side of the RJ11 cable to the WK-CONNECTRJ11port. TheWK-CONNECTpunch-down connection can accept up to two CAT5orCAT6cables. STEP4 Secure the cables with the cable clamps provided. STEP5 Replace the covers. 4Terminating the WK-CONNECT TheWK-CONNECTisusedtoconnectbetweentheWLED75CV1andtheRakoWired network. The WK-CONNECTmustbeterminatedcorrectly otherwise the WLED75CV1 will not function. The termination requirements depend on the nature of the installation and the position of the WK-CONNECT within the system. NoTERM-BothJumpersremoved WhentheWK-CONNECTisnotattheendofline.Thisisusually identifiable by two cables being punched down to the WK-CONNECT. TERM-Jumperfittedacross1+2&4+5 WhentheWK-CONNECTistheendoflineinadaisychain configuration. STARTERM-Jumperfittedacross2+3&5+6 WhentheWK-CONNECTisendoflineinaSTARwireconfiguration. WLED75CV1 Manual Version 2.2.0

Page 5

5AddingtheWLED75CV1intoRasoftPro OncetheWLED75CV1hasbeeninstalledandconnectedtotheRakoWirednetwork,it needs to be assigned as a Device in Rasoft Pro. Thefollowing steps assume: - AProject File has been created. - RoomshavebeenaddedtotheProjectFile. - Channels have been added to the Project File. - TheHUBhasbeenconfigured. If any of the above steps have not been completed, see Wired System Setup Guide. - Connect to the HUB in the communications window by double-clicking it, there will beagreentick to confirm the connection has been successful. - Select “File” - “New device” to bring up the “New device Wizard” and choose “WLED75CV1”fromthelist. - ChooseaDevicename,ifmultiple devices are being programmed it is advised to addauniquedescription. To assign an automatic name and leave the text field blank, tick the box ‘Automatic Name’. - Assign the WLED75CV1 a Room, and leave ‘Associate to new Channel’ blank. WLED75CV1 Manual Version 2.2.0

Page 6

- Press and hold the clear button on the WLED75CV1 for 3-4 seconds until it starts to flash, ‘Device Found’ will appear in the software window. - Select ‘Finish’. NB TheRakoWirednetworkmustbeconnectedandpoweredtotheWLED75CV1for pairing to be successful. TheWLED75CV1hasnowbeenaddedasaDevice,theChannelfortheDevicecanbe found by selecting the Room it was programmed to. WLED75CV1 Manual Version 2.2.0

Page 7

Appendix 1 - Wiring Examples A1.1 STAR Wiring Star Wired systems are connected back to the RAK-STAR unit with individual runs of CAT5 or CAT6 cable, there can be multiple Devices on a single run, although the end of line must beset to ‘STAR’ at the end of line. WLED75CV1 Manual Version 2.2.0

Page 8

A1.2 Radial Wiring Radial wiring connects two or more Devices together in a single continuous run, each end of line must have a ‘Term’ set on the termination jumpers. WLED75CV1 Manual Version 2.2.0