Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Lutron Sivoia QS Smart Panel QSPS-10PNL – installation guide (045528 Rev. E)

Page 1 of 1100%
Text of this document1 page · 2,048 words

Page 1

English Sivoia QS Smart Panel Installation Guide - Please read before installing QSPS-10PNL Input : 120 – 240 V~ 50/60 Hz 10 A Important Notes QSPS-10PNL-NPM Per Output: 35 V- 143 mA 5 W 3 1. For Power Module installation or replacement instructions, please refer to the • If the device will use wired communication, insert the MUX and MUX wires • Flashing LED: Indicates an overload condition has occurred. This may result a. WIN-PS-5CC-R Installation Guide, PN 045550. into the corresponding terminals (refer to the terminal labels at the power from wiring errors or interference with a shade’s motion. After the fault condition 5/16 in (8 mm) 2. All wiring and circuit protection must comply with national and local electrical codes. output receptacle on the circuit board), of the 4-pin terminal block as shown. is cleared, press the Clear Alerts button (see section 6c) to resume operation. Some installations may require a readily accessible disconnect device be incorporated • Tighten each terminal screw securely to 5 in-lb (0.5 N•m), and ensure there 1 a. b. external to the equipment. c. Diagnostic buttons: 3. Minimum feed circuit breaker size: 15 A (limiting factor is inrush current) is no insulation inside the terminal block. 5 in-lb (0.5 N•m) (In some countries, a 16 A circuit breaker may be appropriate.) • Plug the 4-pin terminal block into a power output receptacle. All Lights On: Tap once to turn ON all connected lighting devices 4. Maximum feed circuit breaker size: 20 A • Tighten the strain relief to secure the cable where it enters the enclosure. All Lights Off: Tap once to turn OFF all connected lighting devices 5. This product must be installed by a quali ed electrician. 6. Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0 to 90% humidity, Rules for QS Link Wiring All Shades Open: Tap once to OPEN all connected window treatments non-condensing. b. 7. This product is intended for indoor use only. • QS wiring is NEC Class 2 / PELV. Follow all applicable local and national codes for All Shades Closed: Tap once to CLOSE all connected window treatments 8. This device is not intended for phase-to-phase installations. proper circuit separation and protection. • Power (V+ and COM): 12–18 AWG (4.0–1.0 mm²) Clear Alerts: Tap once to clear all LED alerts and resume normal operation 1 Prepare the Smart Panel • Communication (MUX and MUX): 22 AWG (0.5 mm²) twisted/shielded pair d. Verify communication: Use the All Shades Open button to activate Link N L a. Remove the front cover: Loosen the 4 front cover screws, then slide the cover Diagnostic Mode, and verify active communication to all devices on the QS Link. upward, and lift it off. • V+ terminals must NEVER be connected between outputs • Total length of QS link wiring on Smart Panels outputs (all outputs combined), must • Tap, then press and hold the button for 5 seconds; release and again, tap, b. Remove the line voltage shield: Remove the 2 line voltage shield screws and not exceed 2000 ft (610 m) then press and hold the button for 5 seconds. lift the line voltage shield out of the enclosure. • Total length of QS link wiring on 3-pin communication link (between multiple Smart > The Smart Panel will signal all devices on the QS Link. 4 Panels and system devices) must not exceed 2000 ft (610 m) > All devices receiving the signal will react: 2 Mount the Smart Panel • Maximum of 100 devices per QS link (panel outputs and communication link combined) • LED-equipped devices will ash their LED 1/4 in (6 mm) Mount the Smart Panel in a location that will remain accessible using one of the • Motorized window treatments will “wiggle” following methods (mounting hardware is not provided). NOTE: The 3-pin communication link must be used when interconnecting multiple > Check power and communication wiring of any devices not reacting. a. Surface-mount: Use the 3 keyholes in the back of the enclosure to fasten the Smart Panels. Smart Panels cannot be interconnected using the 4-pin outputs. • The test signal will automatically time out after 10 minutes. 5 in-lb (0.5 N•m) • To exit Link Diagnostic Mode, press and hold the button for 5 seconds. 2 a. a. Smart Panel to the wall. Use fasteners that are appropriate for the mounting Maximum devices Maximum total length of link 4.75 in surface and rated for a 50 lb (23 kg) load. powered per output wiring based on wire gauge (121 mm) b. Recess-mount: Install a horizontal board between the wall studs as a bottom b. support. Fasten the Smart Panel to the right stud and bottom support, inserting Shades + Devices 12 AWG 16 AWG 18 AWG 0.75 in fasteners through the mounting holes provided. (4.0 mm²) (1.5 mm²) (1.0 mm²) (22 mm) None + Up to 2000 ft 1000 ft 600 ft Customer Assistance 3 Connect Line Voltage 8 PDUs* (610 m) (305 m) (183 m) USA and Canada: +1.800.523.9466 (24 hrs / 7 days) 1 shade or + Up to 500 ft 200 ft 125 ft UK +44.(0)20.7680.4481 – 08.00 - 18.00 GMT ! drapery drive 1 PDU* (152 m) (61 m) (38 m) WARNING: RISK OF ELECTRIC SHOCK. Lock the supply circuit breaker in 5 the OFF position before wiring the terminal block. Failure to do so could 2 Roller 64 Up to 200 ft 75 ft 50 ft support@lutron.com | forums.lutron.com result in death or serious injury. 30 sq ft + 1 PDU* (61 m) (23 m) (15 m) Worldwide Headquarters | USA (2.75 sq m) each 1/4 in (6 mm) a. Cable entry: 3 Roller 64 Up to 200 ft 75 ft 50 ft Lutron Electronics Co., Inc. • Remove one of the knockout tabs near the input terminal blocks. 20 sq ft + 1 PDU* (61 m) (23 m) (15 m) 7200 Suter Road, Coopersburg, PA 18036-1299 USA (1.80 sq m) each USA, Canada, Caribbean: 1.844.LUTRON1 (588-7661) 5 in-lb (0.5 N•m) • Install a strain relief device (not included) in the knockout hole. 2 Roller 100 Up to 200 ft 75 ft 50 ft Mexico: +1.888.235.2910 • Run the 10 – 14 AWG (4.0 – 2.5 mm) power wire through the strain relief to 50 sq ft + 1 PDU* (61 m) (23 m) (15 m) Central & South America: +1.610.282.6701 the input terminal blocks at the top left side of the enclosure. (4.60 sq m) each Online: www.lutron.com/help | email: support@lutron.com a. b. * PDU = Power Draw Unit. For more information, refer to the QS Link Power Draw b. Connection: Unit Speci cation Submittal (P/N 369405). Europe Headquarters | United Kingdom • Strip 5 ⁄16 in (8 mm) of insulation from each conductor. In EEA imported by: Lutron EA Ltd • Insert the Line, Neutral, and Ground wires into the terminal block, arranged 5 Connect Multiple Smart Panels and other QS Devices 125 Finsbury Pavement, 4th fl oor, London EC2A 1NQ, UK as shown. TEL: +44.(0)20.7702.0657 | FAX: +44.(0)20.7480.6899 1.50 in • Tighten each terminal screw securely to 5 in-lb (0.5 N•m), and ensure there a. Cable entry: Tech Support: +44.(0)20.7680.448 | FREEPHONE: 0800.282.107 (38 mm) is no insulation inside the terminal block. • Remove the required number of knockout tabs adjacent to the 6.00 in 1.77 in communication pass-through receptacles (labeled Link on the circuit board). Asian Headquarters | Singapore (152 mm) (45 mm) • Tighten the strain relief to secure the cable where it enters the enclosure. Lutron GL Ltd. c. Reinstall the line voltage shield: • Install a strain relief (not included) in each knockout hole to be used. 390 Havelock Road, #07-04 King’s Centre, Singapore, 169662 6 a. • Reattach the line voltage shield removed in step 1b., using the original screws. • Run 3-conductor cable from the other Smart Panel or Sivoia QS device TEL: +65.6220.4666 | FAX: +65.6220.4333 | asiasales@lutron.com b. • through the strain relief. For product warranty information, please see: 16.00 in (406 mm) ! WARNING: RISK OF ELECTRIC SHOCK. Do not energize or operate the b. Connection: www.lutron.com/TechnicalDocumentLibrary/Window Systems Warranty.pdf device without the line voltage shield in place. Ensure all line voltage • Strip 1/4 in (6 mm) of insulation from each conductor. wiring and connections are enclosed behind the shield. Failure to follow these instructions could result in death or serious injury. • Insert the COM, MUX, and MUX wires into the corresponding terminals (refer FCC / IC to the terminal labels at the Link receptacles on the circuit board), of each This device complies with part 15 of the FCC Rules. Operation is subject to a. 4 Connect Lutron Sivoia QS window treatments or lighting devices 3-pin terminal block (2 are provided, packaged separately) as shown. the following two conditions: NOTE: It is recommended that the nal connection between a device and the • Tighten each terminal screw securely to 5 in-lb (0.5 N•m), and ensure there (1) This device may not cause interference. b. is no insulation inside the terminal blocks. (2) This device must accept any interference, including interference that may panel be made at the device after panel installation is complete. Shade limits and cause undesired operation. free operation should be validated immediately after power up to ensure safe • Plug the 3-pin terminal blocks into the Link receptacles. Modifications not expressly approved by Lutron Electronics Co., Inc. could b. operation during commissioning. • Tighten each strain relief to secure the cables where they enter the enclosure. void the user’s authority to operate this equipment. a. Cable entry: Note: This equipment has been tested and found to comply with the limits for 6 Monitor, Verify, Diagnose Operation (with Power Modules installed) a Class B digital device, pursuant to part 15 of the FCC Rules. These limits • Remove knockout tabs from the left side of the enclosure as needed. are designed to provide reasonable protection against harmful interference • Install a strain relief device (not included) in each knockout hole to be used. a. Link LEDs: The QS Link pass-through channel is equipped with status and in a residential installation. This equipment generates, uses and can radiate diagnostic LEDs radio frequency energy and, if not installed and used in accordance with • Run the power cable from a Sivoia QS device through each strain relief. the instructions, may cause harmful interference to radio communications. c. • Diagnostic LED on/ ashing: Connected devices are communicating normally. However, there is no guarantee that interference will not occur in a particular c. b. Connection: • Diagnostic LED off: Connected devices are not communicating. installation. If this equipment does cause harmful interference to radio or ! television reception, which can be determined by turning the equipment off WARNING: RISK OF ELECTRIC SHOCK AND FIRE. Do not interconnect • Status LED on: Indicates Smart Panel is operating properly. and on, the user is encouraged to try to correct the interference by one or power output terminals. Failure to follow these instructions could result in b. Output status LED: Each power output is equipped with a status LED more of the following measures: death or serious injury. — Reorient or relocate the receiving antenna • LED on: Power output and connected devices are operating normally. — Increase the separation between the equipment and receiver • Strip 1/4 in (6 mm) of insulation from each conductor. • LED off: Indicates a short circuit. If no short exists on the output, the power — Connect the equipment into an outlet on a circuit different from that to which • Insert the COM and V+ wires into the corresponding terminals (refer to the supply module has failed and must be replaced. the receiver is connected terminal labels at the power output receptacle on the circuit board), of a — Consult the dealer or an experienced radio/TV technician for help 4-pin terminal block (10 are provided, packaged separately) as shown. This Class B digital apparatus complies with Canadian ICES-003. 11/2017 Lutron Electronics Co., Inc. NEC is a registered trademark of the National Fire Protection Association P/N 045528 Rev E 7200 Suter Road Lutron and Sivoia are trademarks of Lutron Electronics Co., Inc., registered in the U.S. and other countries Coopersburg, PA 18036-1299, U.S.A. O

Need assistance or looking to source this item?