Lutron QSE-CI-DMX Control Interface – specification submittal (369372k)

Page 1 of 8100%
Text of this document8 pages · 2,227 words

Page 1

QS System QSE-CI-DMX Control Interfaces 369372k 1 04.23.26 QSE-CI-DMX Control Interface Description The QSE-CI-DMX operates either in a standalone QS system, a Quantum system, an Athena system, or a HomeWorks system. It performs different functions depending on the system in which it is operating. QS Standalone System The QSE-CI-DMX control interface allows zones on a GRAFIK Eye QS to control DMX512-controlled devices. Any zone on the GRAFIK Eye QS can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB / CMY color-control applications. Quantum, Athena, or HomeWorks Systems The DMX channels (maximum of 32) are mapped to Quantum, Athena, or HomeWorks zones, and can be programmed as 1-channel lighting, 1-channel integration, or 3-channel RGB / CMY. If the QSE-CI-DMX is part of a Quantum or HomeWorks system, GRAFIK Eye QS zones cannot be programmed to control DMX channels. Features • Map any zone on a GRAFIK Eye QS control unit (in QS Standalone systems) or any zone in a Quantum, Athena, or HomeWorks system to any single DMX512 channel • Map any zone on a GRAFIK Eye QS control unit, any Quantum zone, Athena zone, or any HomeWorks zone simultaneously to three DMX512 channels for RGB / CMY color-control • Integral RGB / CMY lookup table that maps GRAFIK Eye QS zone intensities, Quantum zone intensities, Athena zone intensities, or HomeWorks zone intensities to RGB / CMY values (colors) • RGB / CMY table can be customized by using the Lutron QS Color Configuration Tool within the HomeWorks Designer, Quantum Q-Design, or Athena design software • BAA-compliant model number available (UQSE-CI-DMX)* * For a complete list of BAA/TAA compliant products, please visit our website at www.lutron.com/BAA SPECIFICATION SUBMITTAL Page 1 ® Job Name: Model Numbers: Job Number:

Page 2

QS System QSE-CI-DMX Control Interfaces 369372k 2 04.23.26 Specifications Regulatory Approvals Limitations • RoHS Compliant • In a Quantum, Athena, or HomeWorks system, • CE Marked the 32 channels can be any of the 512 available • NOM addresses within the DMX universe. DMX mergers • cULus can be used if more than 32 DMX channels need to Power Requirements be controlled within a single DMX universe • Low-voltage SELV / PELV / NEC Class 2 • Daylighting is not supported for DMX loads ® • Loadshedding is not supported for DMX loads • Operating Voltage: 24 – 36 V- 65 mA • Nightlighting is not supported for DMX loads Environment • D MX 1-channel lighting can be raised / lowered, but • 32 °F to 104 °F (0 °C to 40 °C) DMX 1-channel integration and DMX 3-channel • Relative humidity less than 90% non-condensing lighting cannot • Unit generates heat, maximum 8 BTU / hr Note: In a QS standalone system, raise / lower System / Device Capabilities / Limits can be used to cycle through colors from a customizable RGB color table using the Lutron QS • E ach QSE-CI-DMX control interface counts as 1 QS DMX Color Programming Tool device and 0 zones. For QS system link limits, refer Requirements to the Lutron Residential and Commercial System The QSE-CI-DMX requires the following: Rules Specification Submittal (P/N 369982) at • At least one GRAFIK Eye QS control unit connected www.lutron.com for more information to the QSE-CI-DMX through the QS communication • Each DMX channel = 1 switch leg. Refer to the Lutron link, Residential and Commercial System Rules or Specification Submittal (P/N 369982) at A Quantum system www.lutron.com for more information or • One QSE-CI-DMX per QS link in QS standalone. A HomeWorks system Up to 16 QSE-CI-DMX interfaces per QS link in or HomeWorks, Athena, or Quantum systems An Athena system • 32 DMX channels per QSE-CI-DMX control interface • Q S Link power supply capable of providing 2 • Each QSE-CI-DMX control interface consumes 2 PDUs. Refer to the QS Link Power Draw Units Power Draw Units (PDU) on the QS link. Refer to the Specification Submittal (P/N 369405) at QS Link Power Draw Units Specification Submittal www.lutron.com for more information (P/N 369405) at www.lutron.com for more information • DMX512 link terminators at both ends of the DMX512 QS Link Wiring Limits link (available from Lutron, part number LT-1a) • Total length of link must not exceed 2000 ft (610 m) • Q S Communication Link Wire (SELV / PELV / NEC • Do not allow SELV / PELV / NEC Class 2 wires to Class 2). See the Wire Sizes table ® ® contact line / mains wires DMX512 Link System Limits • Consult your DMX equipment installer DMX512 Link Wiring Limits • E ach terminal can accept up to two 18 AWG 2 (1.0 mm ) wires • Link must be 1000 ft (305 m) or less • DMX Link must begin and end with link terminators (available from Lutron; part number LT-1a) • Three pins on the DMX connector for connecting the QSE-CI-DMX to DMX512-controlled equipment SPECIFICATION SUBMITTAL Page 2 ® Job Name: Model Numbers: Job Number:

Page 3

QS System QSE-CI-DMX Control Interfaces 369372k 3 04.23.26 Example Application The QSE-CI-DMX can be programmed so that any or all zones on a GRAFIK Eye QS control unit can control either 3 channels (e.g., RGB) or 1 channel (i.e., intensity of a single light). Raising or lowering a zone will change the color (for a 3-channel zone) or the intensity (for a 1-channel zone). If, for example, you have an RGB LED fixture and a single stage light, you can configure your settings as shown in the table below: GRAFIK Eye QS Zone Zone Configuration Controls DMX Fixture affected address(es) 1 RGB / CMY DMX 3, 4, and 5 RGB LED fixture 2 DMX 6 Intensity of stage light Example use cases: • Scene activation: When you select a pre-programmed scene on the GRAFIK Eye QS control unit, it can send any or all zones on the GRAFIK Eye QS to pre-programmed levels • Zone adjustment: The individual zone raise / lower buttons on the GRAFIK Eye QS can be used to fine-tune the levels of each zone. For example, raising zone 2 (shown in the table above) will increase the intensity of the stage light GRAFIK Eye QS control unit QSE-CI-DMX LUTRON SELV / PELV / NEC® Class 2 DMX output QS link wiring for system communication SPECIFICATION SUBMITTAL Page 3 ® Job Name: Model Numbers: Job Number:

Page 4

QS System QSE-CI-DMX Control Interfaces 369372k 4 04.23.26 Dimensions Dimensions are in inches (mm) 2.5 Mounting holes (63) Terminal blocks LEDs and addressing on this side switches on this side 3.75 4.25 Mounting Hole Detail (95) (108) 0.1875 (5) dia. 0.3125 (9) dia. 5.25 0.1875 (134) (5) dia. 0.25 (6) 1.0 #6 or #8 (M3 or M4) (27) screw recommended Mounting Options Mount where terminal blocks, switches, and LEDs Mounting Methods are accessible. Strip 3/8 in (10 mm) of insulation from wires. Each data link terminal will accept up 1 2 2 to two 18 AWG (1.0 mm ) wires. Connect wiring as shown on the Wiring page. LED 1 is continuously lit (Power) and LED 7 blinks rapidly (Data Link RX) when the SELV / PELV / NEC® Class 2 Data Link is installed correctly. Choose from the following LUT-19AV-1U mounting methods: 1. Direct Wall Mounting 3 Mount the control interface directly on a wall, as Wall 2.50 shown in Mounting Methods at right, using screws (not included). When mounting, provide Control Interface sufÏcient space for connecting cables. 2. Rack Mounting 3.75 4.26 Place the unit in the LUT-19AV-1U AV rack using screws provided with the unit. The LUT-19AV-1U LUT-5x10-ENC will hold up to four units. 5.26 3. Enclosed Wall Mounting If conduit is desired for wiring, use the 1.06 LUT-5x10-ENC to mount one unit. SPECIFICATION SUBMITTAL Page 4 ® Job Name: Model Numbers: Job Number:

Page 5

QS System QSE-CI-DMX Control Interfaces 369372k 5 04.23.26 SELV / PELV / NEC Class 2 QS Link Requirements and Wiring ® • System communication uses SELV / PELV / NEC® Class 2 wiring • Wiring can be daisy-chained or T-tapped (see below) • Wiring must be run separately from line / mains voltage • Total length of control link must not exceed 2000 ft (610 m) • Connect the terminal 1, 3, and 4 connections to all control units, wallstations, and control interfaces. See Powering the QSE-CI-DMX for pin 2 connectivity • The QSE-CI-DMX consumes 2 Power Draw Units (PDUs) on the QS link. For more information, see Power Draw Units on the QS Link, PN 369405, at www.lutron.com/qs Wire Sizes (check compatibility in your area) QS Link Wiring Length Wire Gauge Lutron Cable Part Number Less than 500 ft (153 m) Power (terminals 1 and 2) GRX-CBL-346S (non-plenum) 2 1 pair 18 AWG (1.0 mm ) GRX-PCBL-346S (plenum) Data (terminals 3 and 4) 2 1 twisted, shielded pair 22 AWG (0.5 mm ) 500 to 2000 ft Power (terminals 1 and 2) GRX-CBL-46L (non-plenum) 2 (153 to 610 m) 1 pair 12 AWG (4.0 mm ) GRX-PCBL-46L (plenum) Data (terminals 3 and 4) 2 1 twisted, shielded pair 22 AWG (0.5 mm ) Daisy-Chain Wiring Example GRAFIK Eye QS seeTouch QS control unit wallstations QSE-CI-DMX LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON Sivoia QS power panel T-Tap Wiring Example seeTouch QS GRAFIK Eye QS wallstations control unit LUTRON Sivoia QS LUTRON LUTRON LUTRON LUTRON power panel LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON Sivoia QS LUTRON shade QSE-CI-DMX LUTRON (powered separately) LUTRON QSPS power supply SPECIFICATION SUBMITTAL Page 5 ® Job Name: Model Numbers: Job Number:

Page 6

QS System QSE-CI-DMX Control Interfaces 369372k 6 04.23.26 SELV / PELV / NEC Class 2 Terminal Connections ® Wire Sizes (check compatibility in your area) QS Link Wiring Length Wire Gauge Lutron Cable Part Number Less than 500 ft (153 m) Power (terminals 1 and 2) GRX-CBL-346S (non-plenum) 2 1 pair 18 AWG (1.0 mm ) GRX-PCBL-346S (plenum) Data (terminals 3 and 4) 2 1 twisted, shielded pair 22 AWG (0.5 mm ) 500 to 2000 ft Power (terminals 1 and 2) GRX-CBL-46L (non-plenum) 2 (153 to 610 m) 1 pair 12 AWG (4.0 mm ) GRX-PCBL-46L (plenum) Data (terminals 3 and 4) 2 1 twisted, shielded pair 22 AWG (0.5 mm )

Connect Drain / Shield as shown. Do not connect to Ground (Earth) or Wallstation / Control Interfaces. Connect the bare drain wires and cut off the outside shield. Data Link: (1) shielded, twisted 2 pair 22 AWG (0.5 mm ) 4: MUX 3: MUX D: Drain / Shield Note: Do not connect Drain / Shield to Ground (Earth) or Wallstation / Control QSE-CI-DMX (2) 12 AWG Interfaces. Connect the bare drain 2 wires and cut off the outside shield. (4.0 mm ) 2 Note: 12 AWG (2.5 mm ) conductors for Common (terminal 1) and V+ Power (terminal 2) will not fit in terminals; use 2 SELV / PELV / NEC (Class 2: USA) 18 AWG (1.0 mm ) pigtails (< 6 in [152 mm]). ® Power wiring: (2) 12 AWG 1: Common 2 (4.0 mm ) 2: V+ 2 (2) 18 AWG (1.0 mm ) pigtails, To DMX equipment 6 in (152 mm) maximum length SPECIFICATION SUBMITTAL Page 6 ® Job Name: Model Numbers: Job Number:

Page 7

QS System QSE-CI-DMX Control Interfaces 369372k 7 04.23.26 Powering the QSE-CI-DMX • The QSE-CI-DMX requires 2 PDUs (Power Draw Units) on the QS link. The GRAFIK Eye QS ouptuts 3 PDUs on the QS link, so it is capable of powering a single QSE-CI-DMX with 1 PDU to spare • The QSE-CI-DMX can also be powered from a QS Link power supply (QSPS-P1-1-35V, QSPS-P2-1-35V, or QSPS-P3-1-35V); a QS shade panel power supply (QSPS-10PNL for 230 V~, or QSPS-10PNL for 120 V~); or a Quantum light management hub • For more information on PDUs (Power Draw Units), see the Lutron PDU Spec Submittal (P/N 369405) at www.lutron.com Wiring Examples QSE-CI-DMX Powered by a GRAFIK Eye QS Control Unit DMX Link QS Link Rear View of GRAFIK Eye QS control unit QS link: 1 : Common 2: V+ 3: MUX 4: MUX QSE-CI-DMX Powered by a QSPS Power Supply GRAFIK Eye QS seeTouch QS control unit wallstations QSE-CI-DMX (powered separately by QSPS) LUTRON LUTRON LUTRON LUTRON DMX Link QS Link Lutron Cable QSPS GRX-CBL-346S-500 power supply SPECIFICATION SUBMITTAL Page 7 ® Job Name: Model Numbers: Job Number:

Page 8

QS System QSE-CI-DMX Control Interfaces 369372k 8 04.23.26 DMX512 Link Wiring Connect the DMX link terminals on the QSE-CI-DMX interface to input terminals on DMX512-controlled equipment. 2 • Each terminal on the QSE-CI-DMX accepts two 18 AWG (1.0 mm ) wires • Link must be 1000 ft (305 m) or less • Link must begin and end with link terminators (available from Lutron; part number LT-1a) Pin on QSE-CI-DMX Terminal Connection to DMX Equipment 1: DMX512 system COMMON DMX512 system COMMON Note: Do NOT connect to COMMON on GRAFIK Eye QS control unit or other Lutron equipment NC Not connected 3: DMX512 system DATA + DMX512 system DATA + 4: DMX512 system DATA - DMX512 system DATA - Lutron, Athena, GRAFIK Eye, HomeWorks, seeTouch, Sivoia, Q-Design, Quantum, and any related trade dress and logos are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. All other product names, logos, and brands are property of their respective owners. SPECIFICATION SUBMITTAL Page 8 ® Job Name: Model Numbers: Job Number: