R Control Unit Preset Dimming Controls QSG-105.08.07 GRAFIK Eye® QSControl Unit Description • Provides pushbutton recall of four preset lighting scenes, plus Off. • Offers optional integrated shade control buttons, which can be added to the unit after installation. • Includes master override buttons to Open 1 temporarily raise and lower all lights. Preset 2 Close 3 • Allows setup of lighting scenes and shade 4 presets using buttons on the control unit. Off • Controls many light source types directly and LUTRON others using power interfaces. • Provides individual control of light sources. • Includes built-in infrared receiver. • Includes external IR connection. • Includes built-in astronomic timeclock. • Provides info screen for zone light level percentage, energy savings, zone labeling, accessing additional scenes, programming, 1 2 3 4 5 6 and timeclock scheduling. • Info screen is language-selectable. OK • Provides lockout options to prevent accidental changes. • Includes one occupant sensor input and Open 1 24 V power for occupant sensors or other Preset 2 building management systems. Close 3 4 • Includes communication link for seamless Off integration of lights, motorized window treatments, and control stations. • Backlit buttons with optional engraving make unit easy to find and to operate. • Available in a variety of colors and finishes to match any decor. • Compatible with all Lutron QS system components. Optional Zone Infrared Lighting Info shade control receiver control screen control keypad keypad Note: General Engraving (-EGN) shown. R SPECIFICATION SUBMITTAL Page1 Job Name: Model Numbers: Job Number:
Page 2
R Control Unit Preset Dimming Controls QSG-205.08.07 Specifications Input Power Scene and Shade Buttons • 120 V 50/60 Hz. • Large, rounded buttons are easy to use. • Lightning strike protection meets ANSI/IEEE standard • Backlit buttons with optional engraving make it easy to 62.41-1980. Can withstand voltage surges of up to find and to operate the control unit in low light 6000 V and current surges of up to 3000 A. conditions. Lighting Sources/Load Types • Optional button engraving is angled up to the eye for easy reading. Controls the following lighting sources with a smooth, • Predefined label stickers are included for field labeling. continuous square law dimming curve or on a full conduction non-dim basis: Preset Light and Shade Control • Incandescent. • 4 preset lighting scenes, plus Off, are accessible from • Magnetic low-voltage transformer. the front of the control unit. • Lutron Tu-Wire® electronic fluorescent dimming ballast. • 12 additional scenes are stored in the control unit. • Neon and cold cathode. These are accessible via the info screen or via other • Non-dim. control stations. Controls the following lighting sources with a smooth, • Light levels fade smoothly between scenes. Fade time continuous square law dimming curve through separate can be set differently for each scene: 0 to 59 seconds, power interfaces: or 1 to 60 minutes. Fade time from Off is capped at • Electronic low-voltage transformer. 5 seconds. • Lutron Hi-Lume® and Eco-10TM electronic fluorescent • Open, preset, and close shade buttons. Raise and dimming ballast. lower is also available for each shade column. Each shade column can be programmed to operate one Key Design Features shade or multiple shades (a group of shades). • Meets IEC 801-2. Tested to withstand 15 kV Zone Control electrostatic discharge without damage or • Each zone has a dedicated raise and lower button to memory loss. adjust the zone. • Compensates in real time for incoming line voltage • Each zone has a dedicated 7 LED bar graph for level variations (no visible flicker with +/-2% change in RMS status. Light % and energy saved % is displayed on voltage per cycle, and +/-2% Hz change in frequency per the info screen. second). • All zone information has blue backlit LEDs. Backlight is • 10-year power failure memory automatically restores programmable to Off. lighting to the scene selected prior to power • 4 preset scenes can be programmed as zone toggles. interruption, and stores timeclock and scene Zones to toggle are fully programmable to integral and programming. external zones. • Faceplate is hinged top and bottom and stays open at 180° for ease of access. Info Screen Environment • Screen is viewable from all angles. • 32-104 °F (0-40 °C). • Programmable zone labels. • Relative humidity less than 90% non-condensing. • Programmable scene labels. • Status of real-time zone percentage and energy Standards savings. • UL listed. • Programmable timeclock schedules. • CSA. • NOM. R SPECIFICATION SUBMITTAL Page2 Job Name: Model Numbers: Job Number:
Page 3
R Control Unit Preset Dimming Controls QSG-305.08.07 Specifications Astronomic Timeclock • Integral to all units. • 7 daily schedules available. • Holiday schedules are programmable by date up to one year in advance. • 25 events per day available. • Astronomic times are programmable by integral city database or by entering latitude and longitude. Times automatically adjust throughout the year based on location. • Automatically adjusts for Daylight Saving Time, adjusted for the new 2007 dates. • California Energy Commission, complies with Title 24. System Communications and Capacities System Limits • Low-voltage type PELV (Class 2: USA) wiring connects QSDevice Zone Count Device Count control units, wallstations, motorized shades, and control 3-zone QS 3 1 interfaces. LUTRON • A QS system can have up to 100 devices and 100 zones 4-zone QS 4 1 LUTRON (see table at right). 6-zone QS 6 1 Infrared LUTRON seeTouch QS 0 1 • Infrared receiver allows infrared transmitters to select 8 LUTRON scenes, raise/lower lighting zones, or raise/lower shades. Sivoia QS 1 1 • Transmitter buttons imitate buttons on faceplate. • 50 ft. (15 m) line of sight range. • Terminal block infrared input for direct contact with external IR connection. • IR can be disabled via programming. Accessory Controls • SeeTouch QS controls can be added to the control link. • Each GRAFIK Eye QS can power up to 3 SeeTouch QS controls. • Works with Lutron GRX-IT and GRX-8IT infrared remote controllers. Occupant Sensor Connection • Control unit supplies power for and receives a control signal back from one occupant sensor. • One contact closure input can be programmed to select a scene on the contact closing, opening, or both. No power pack required. • Power Supply Output (Terminal B): - 24 V , 50 mA maximum. - An auxiliary power supply must be used if the device requires more than 50 mA. • Occupant Sensor Signal Input (Terminal A): - The occupant sensor must provide a dry contact closure or solid-state output. • Control unit is miswire-protected up to 36 V . R SPECIFICATION SUBMITTAL Page3 Job Name: Model Numbers: Job Number:
Page 4
R Control Unit Preset Dimming Controls QSG-405.08.07 Mechanical Dimensions 9-3/8 in. (239 mm) 3/8 in. (10 mm) 1-13/16 in. (46 mm) 4-11/16 in. (119 mm) Front View Side View Fits into a 4-gang U.S. backbox, 3.5 in. (89 mm) deep; Lutron P/N 241-400 R SPECIFICATION SUBMITTAL Page4 Job Name: Model Numbers: Job Number:
Page 5
R Control Unit Preset Dimming Controls QSG-505.08.07 Standard GRAFIK Eye QS Model Numbers See following pages for Custom Options and Model Numbers See Standard Color Combinations page for faceplate, stripe, and button colors QSG - 3P120 - WH QSG - 3P120 - TWH QSG - 4P120 - WH QSG - 4P120 - TWH QSG - 6P120 - WH QSG - 6P120 - TWH Prefix Phase Control Voltage Triac Number Top Door Unit of Zones Color Color/Finish 3 = 3 zones Omit = same Architectural 4 = 4 zones as unit Matte 6 = 6 zones T = Translucent Finishes WH White Mechanical Dimensions Fits into a 4-gang U.S. backbox, 3.5 in. (89 mm) deep; Lutron P/N 241-400 Capacities Zones Unit Capacity Zone Capacity Unit Dissipation (watts) (watts) (BTUs/hour) 3 2000 800 61.5 4 2000 800 61.5 6 2000 800 61.5 R SPECIFICATION SUBMITTAL Page5 Job Name: Model Numbers: Job Number:
Page 6
R Control Unit Preset Dimming Controls QSG-605.08.07 Custom GRAFIKEye QS Model Numbers See previous page for Standard Model Numbers See following page for Custom Options and Model Numbers See Standard Color Combinations page for faceplate, stripe, and button colors QSG - _ P120 - _ _ ___ - __ Prefix Phase Unit Control Voltage Color/Finish Keypad Triac Engraving Number Code Number of Shade Top Door of Zones Zones Color 3 = 3 zones Omit = none Omit = same 4 = 4 zones 1 = 1 zone as unit 6 = 6 zones 2 = 2 zones T = Translucent 3 = 3 zones Custom Keypad Engraving Codes Colors/Finishes Omit = Unengraved Architectural Matte Satin Color Matte EGN = General Engraving Finishes Finishes NST = Non-Standard Text Engraving Standard Snow SW Please visit the GRAFIK Eye QS website at (ship in 48 hours) Biscuit BI wwwwww..lluuttrroonn..ccoomm//ggrraaffiikkeeyyeeqqss for custom White WH Eggshell ES engraving forms Ivory IV Taupe TP Beige BE Midnight MN Gray GR Limestone LS Brown BR Stone ST Black BL Desert Stone DS Almond AL Terracotta TC Light Almond LA Hot HT Goldstone GS Architectural Metal Palladium PD Finishes Plum PL Bright Brass BB Turquoise TQ Bright Chrome BC Bluestone BG Bright Nickel BN Sea Glass SG Satin Brass SB Greenbrier GB Satin Chrome SC Sienna SI Satin Nickel SN Merlot MR Mechanical Dimensions Antique Brass QB Mocha Stone MS Antique Bronze QZ Fits into a U.S. 3.5 in. (89 mm) deep 4-gang backbox Anodized Aluminum Capacities Finishes See previous page Clear CLA Black BLA Brass BRA R SPECIFICATION SUBMITTAL Page6 Job Name: Model Numbers: Job Number:
Page 7
R Control Unit Preset Dimming Controls QSG-705.08.07 GRAFIKEyeQS Custom Options and Model Numbers See previous pages for Standard and Custom Model Numbers See Standard Color Combinations page for faceplate, stripe, and button colors Faceplate Kit Stripe Kit (includes coordinating stripe and buttons) QSGF - 3T WH - ___ QSGS - WH Faceplate Number Top Door Unit Keypad Stripe Stripe Prefix of Shade Color Color/ Engraving Kit Color/Finish Zones Finish Code Prefix Omit = none Omit = same Stripe Custom Color/Finish Codes 1 = 1 zone as unit Same as Faceplate colors at left 2 = 2 zones T = Translucent 3 = 3 zones Faceplate Custom Keypad Engraving Codes Color/Finish Codes Omit = Unengraved Architectural Matte Anodized Aluminum EGN = General Engraving Finishes Finishes NST = Non-Standard Text Engraving Standard Clear CLA Please visit the GRAFIK Eye QS website at (ship in 48 hours) Black BLA wwwwww..lluuttrroonn..ccoomm//ggrraaffiikkeeyyeeqqss for custom White WH Brass BRA engraving forms Ivory IV Beige BE Satin Color Matte Gray GR Finishes Brown BR Snow SW Black BL Biscuit BI Almond AL Eggshell ES Light Almond LA Taupe TP Midnight MN Architectural Metal Limestone LS Finishes Stone ST Bright Brass BB Desert Stone DS Bright Chrome BC Terracotta TC Bright Nickel BN Hot HT Satin Brass SB Goldstone GS Satin Chrome SC Palladium PD Satin Nickel SN Plum PL Antique Brass QB Turquoise TQ Antique Bronze QZ Bluestone BG Sea Glass SG Greenbrier GB Sienna SI Merlot MR Mocha Stone MS R SPECIFICATION SUBMITTAL Page7 Job Name: Model Numbers: Job Number:
Page 8
R Control Unit Preset Dimming Controls QSG-805.08.07 GRAFIKEyeQS Custom Options and Model Numbers See previous pages for Standard and Other Custom Model Numbers See Standard Color Combinations page for faceplate, stripe, and button colors Button Kit QSGB - 5B - WH - Custom Button Button Button Keypad Kit Prefix Configuration Color/ Engraving Finish Code 3BRL = 3-button with raise/lower (shade keypad) 5B = 5-button Keypad Engraving Codes (lighting keypad) Omit = Unengraved EGN = General Engraving Button Kit Custom NST = Non-Standard Text Engraving Please visit the GRAFIK Eye QS website at Color/Finish Codes wwwwww..lluuttrroonn..ccoomm//ggrraaffiikkeeyyeeqqss for custom Architectural Matte Satin Color Matte engraving forms Finishes Finishes White WH Snow SW Ivory IV Biscuit BI Beige BE Eggshell ES Gray GR Taupe TP Brown BR Black BL Almond AL Light Almond LA R SPECIFICATION SUBMITTAL Page8 Job Name: Model Numbers: Job Number:
Page 9
R Control Unit Preset Dimming Controls QSG-905.08.07 GRAFIKEyeQS Standard Color Combinations See previous pages for Standard and Custom Model Numbers Faceplate is comprised of a top and bottom. The bottom will always be the color indicated F (faceplate) under “faceplate.” The top may be the same color or translucent. Use the chart for faceplates that have the same color top and S(stripe) bottom. If a translucent lid is chosen, the stripe will automatically be the same color as Open 1 the bottom lid. Preset 2 B(buttons) Close 3 Example: 4 F (faceplate) If you order QSG-4P120-1WH, your GRAFIK Off LUTRON Eye QS with 4 lighting zones and 1 shade zone will come with a white faceplate (both top and bottom), gray stripe, and white buttons. Suffix Faceplate (F) Stripe (S) Button (B) Suffix Faceplate (F) Stripe (S) Button (B) Architectural Matte Satin Matte WH White Gray White MN Midnight Gray Black IV Ivory Beige Ivory TP Taupe Gray Taupe BE Beige Ivory Beige SW Snow Gray Snow GR Gray Black Gray ES Eggshell Beige Eggshell BR Brown Black Brown BI Biscuit Eggshell Biscuit BL Black Gray Black LS Limestone Gray Gray AL Almond Light Almond Almond ST Stone Gray Gray LA Light Almond Almond Light Almond DS Desert Stone Taupe Taupe Architectural Metal TC Terracotta Taupe Taupe BB Bright Brass Black Black BG Bluestone Gray Gray BC Bright Chrome Black Black HT Hot Taupe Taupe BN Bright Nickel Black Black MR Merlot Taupe Taupe SB Satin Brass Black Black SI Sienna Brown Brown SC Satin Chrome Black Black GB Greenbrier Gray Gray SN Satin Nickel Black Black SG Sea Glass Gray Gray QB Antique Brass Black Black MS Mocha Stone Taupe Taupe QZ Antique Bronze Black Black GS Goldstone Ivory Ivory Anodized PD Palladium Gray Gray CLA Clear Black Black PL Plum Taupe Taupe BLA Black Black Black TQ Turquoise Gray Gray BRA Brass Black Black R SPECIFICATION SUBMITTAL Page9 Job Name: Model Numbers: Job Number:
Page 10
R Control Unit Preset Dimming Controls QSG-10 05.08.07 Wiring Diagrams Terminations Communication link 123456LN Occupant sensor/contact closure input and 24 V power 1234 ABC 12 IR input Load wiring PELV(Class 2: USA) QS System Low-Voltage Terminal Connections 2 • Each PELV (Class 2: USA) terminal accepts up to two #18 AWG (1.0 mm ) wires. • Connect the terminal 1, 3, and 4 connections to all control units, wallstations, and control interfaces. • Each control unit has its own power supply. Terminate the terminal 2 connection (24 V power) so that each control unit supplies power to a maximum of three wallstations. Each wallstation should receive power from only one control unit. • Total length of control link must not exceed 2,000 ft. (610 m). • Do not allow PELV (Class 2: USA) wires to contact line/mains wires. Control units shown in rear view 123456HN A3 1234 A3 powers wallstations 2, 3, ABC 12 and 4; no terminal 2 connection between A2 and A3 wallstations 4 and 5 123456HN have their A1 1234 own power 5 ABC supply; no 4 3 12 terminal 2 2 connection 1 6 Sivoia QS 4 power panel 3 1 2 2 1 4 4 P1 3 3 P1 2 2 1 1 7 powers shade 4 A1 powers wallstation 1 3 S1 only 3 2 only; terminal 2 1 terminates at wallstation 1 4 3 2 1 Sivoia QS 123456HN shade 123456HN 4 1234 1234 4 A4 ABC A2 3 ABC 2 12 S1 12 1 A4 powers wallstations 5, 6, and 7 only; no terminal 2 connection between wallstations 4 and 5 R SPECIFICATION SUBMITTAL Page10 Job Name: Model Numbers: Job Number:
Page 11
R Control Unit Preset Dimming Controls QSG-11 05.08.07 Mounting Mounting screws (4) Standard 4-gang Hinged U.S. wallbox, 3.5 top lid in. (89 mm) deep GRAFIKEye QS control unit Hinged bottom lid Line Voltage Wiring Rear of QS control unit 123456LN To Load 1 To Load 2 Line voltage (hot/live) To Load 3 is labeled L. To Load 4 To Load 5 To Load 6 LN Distribution Panel • Pull power wiring from distribution panel and to light fixtures. 2 • Each line voltage terminal can accept one #12 AWG (2.5 mm ) wire. • Consult Lutron for non-dim relay wiring and/or load side emergency transfer wiring. R SPECIFICATION SUBMITTAL Page11 Job Name: Model Numbers: Job Number:
Page 12
R Control Unit Preset Dimming Controls QSG-12 05.08.07 PELV(Class 2: USA) QS System Low-Voltage Wiring • System communication uses low-voltage wiring. • Wiring can be daisy-chained or T-tapped. • Wiring must be run separately from line/mains voltage. • PELV (Class 2: USA) wiring link requires: 2 Two #18 AWG(1.0 mm)conductors for control power. 2 One twisted, shielded pair of #22 AWG (1.0 mm ) for data link. Available from Lutron, P/N GRX-CBL-346S; check compatibility in your area. • Total length of control link must not exceed 2,000 ft. (610 m). Daisy-Chain Wiring Example QS Sivoia QS SeeTouch QS Control Unit Shade LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON LUTRON Sivoia QS power panel T-Tap Wiring Example QS Control Unit SeeTouch QS LUTRON LUTRON LUTRON LUTRON Sivoia QS power panel Sivoia QS LUTRON Shade LUTRON LUTRON R SPECIFICATION SUBMITTAL Page12 Job Name: Model Numbers: Job Number: