TSLM-3 TELESCOPIC SCREEN LIFT MEDIUM TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
TSLM-3 TELESCOPIC SCREEN LIFT MEDIUM SPECIFICATION MEASUREMENTS Product Dimensions 892mm (35 1/8") x 1280mm (50 3/8") x 240mm (9 7/16") Minimum Screen Height 850mm (33 7/16") Maximum Screen Height 1175mm (46 1/4") Minimum Screen Width 1280mm (50 3/8") - (Lower Width option available apon request) Maximum Weight Capacity 75Kg (165lb) (Screen + Enclosure) Product Weight 45Kg (99lb) Packaging Dimensions TBC Shipping Weight TBC Movement Type Motorised Power Supply Required 110V - 240V Power Consumption Max. 250W Power Consumption Standby 3W Mounting Patterns Supported VESA 200, 300, 400 W x 200, 300, 400 H - (Other VESA patterns apon request) Control Options IR Remote, RS232, Contact Closure Product Options / Features Specific B&O and Loewe mounts / adapters, Custom RAL paint finishes, Outdoor suitable version Package Contents Mechanism, IR remote control Marine Suitable YES Outdoor Suitable NO TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
TSLM-3 TELESCOPIC SCREEN LIFT MEDIUM GENERAL INFORMATION VESA 200, 300 & 400 LID and ENCLOSURE - To be mounting patterns covered. made by others. Total allowable Bracket has full height weight for all timber work and the adjustment . screen 75Kg. The lid must be easily removed if the mechanism was stuck in the down position. A lift off arrangement being ideal. The fixings for the screen are then accessible so it can then be lifted off to give access to the motor. Screen Screen cables cables enter here. enter here. TRIM PANEL - Not supplied. Front access is required to install the lift. This trim panel is lifted up as the screen is lowered into the Allow 20mm+ in front of the screen if cabinet. Brackets are the mechanism is to be partially sunk supplied to attach it. below floor level. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
TSLM-3 TELESCOPIC SCREEN LIFT MEDIUM 13/16" 20 CABINET SIZING Box Enclosure Cap Height All sizing calculations are based off a 20mm [0.79"] C box enclosure panel thickness. Any increases in this thickness will increase the required space. A Internal Cabinet Depth = Screen Depth + 230 [9 1/16"] Box Enclosure Depth = Screen Depth + 100 [3 15/16"] B B 3 11/16" Screen DETAIL C 93 Depth SCALE 1 : 3 Back of Cabinet to Aperture Aperture Depth = Screen Height Screen Depth + 116 [4 9/16"] A Min. 850 [33 7/16"] Max. 1175 [46 1/4"] SECTION B-B SCALE 1 : 7 888 34 15/16" 13/16" 20 Box Enclosure Height = Screen Height + 30 [1 3/16"] Internal Cabinet Height = Screen Height + 55 [2 3/16"] Mechanism Back Tray Height Screen Width Box Enclosure Width = Screeen Width +50 [1 15/16"] SECTION A-A Aperture Depth = Screen Depth + 66 [2 5/8"] SCALE 1 : 7 Internal Cabinet Width = Screen Width + 100 [3 15/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
TSLM-3 TELESCOPIC SCREEN LIFT MEDIUM 15° Suggested Taper BOX ENCLOSURE DETAILING 0" 0 Block to locate The Screen, Enclosure, Lid and the Trim 1/4" in enclosure panel must weigh no more than 75Kg. 7 E 13/16" 20 Optional ventilation DETAIL E SCALE 1 : 1 Suggested taper detail to help prevent finger traps Fixing Brackets Blocks to locate lid. 25 3/16" 640 44 7/8" 1140 D D 31 7/8" 810 11 13/16" 22 1/16" 300 560 1/2" 12 Trim Panel 22 13/16" 1/4" 13/16" 580 7 20 23 5/8" 3 9/16" 600 90 SECTION D-D 13 3/8" 340 Enclosure also fixed along here TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 5 FUTUREAUTOMATION
Page 6
TSLM-3 TELESCOPIC SCREEN LIFT MEDIUM Mount fixing bolts INSTALL INSTRUCTIONS F Check that the cabinet, enclosure, lid and the trim panel are made to the details shown on the previous pages. • You can stand the mechanism up on its base to test it before putting in the cabinet. See control document for details. Use the IR remote with caution and always cover the STOP button in case of issues. Mount bracket • Centrally fix the mechanism to the back of the cabinet in the places shown. Enclosure • Run up and down and then add the enclosure. • Adjust the position of the enclosure and adjust the up and down switches with caution. Temporarily add lid to check height. • Run screen cables up into enclosure. Secure cables as they enter and leave the cable tracks with cable ties. Make sure no cables can get tangled or caught as the Trim Panel Fixing holes mechanism moves. • Add trim panel. And adjust. This trim panel moves up into position as the TV lifts. Observe this movement and Either or both Up Switch cable tracks can understand it before fixing. be used. • The upright plate can be adjusted in height by moving it Down Switch to a different set of keyholes. Fix the plate to the back of the screen and mount to mechanism using the keyholes. Ensure the plate is secured using the fixing bolts located at the top of the keyhole plates. Fixing holes • Check movement with screen with caution. SECTION F-F F TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 6 FUTUREAUTOMATION
Page 7
TSLM CONTROL BOX CONTROL BOX FOR TELESCOPIC SCREEN LIFT
307.5 12 1/8"
RS232 PORT IR OUTPUT CABLE LOOM INDICATOR LED CONTACT LENGTH APPROX CLOSURE 118 1/8" PORT 3000 IR LEAD INPUT 3.5mm [0.14"] JACK EMERGENCY STOP CONNECTOR
20 max 0.79 max 1/4"
5/16"
8 CORE CABLE 52.1 MOTOR 2 1/16"
10mm [0.4"] dia. MAINS INPUT 3 CORE CABLE EU SPEC: 0.5mm² 5.2 3/16" 5 7/8" SWITCH LIMITS
US SPEC: 20AWG 149.5 6mm [0.25"] dia. EU SPEC: 0.5mm² NOTES US SPEC: 20AWG • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 7 FUTUREAUTOMATION
Page 8
TSLM TELESCOPIC SCREEN LIFT MEDIUM General Mitigations: INTEGRATION CONSIDERATIONS • Implement a hold to run/dead man switch operation. • Control methods should be located within direct line of site of the mechanism. High Risk - Crush Hazard • Implement password or key switch protected operation. Crush hazard between the top panel and the Top panel cabinet top as the lift closes. Mitigation The top panel can also be floating/not permanently fixed to allow vertical movement if an obstruction is caught between it and the cabinet top. Keep all shadow gaps to a minimum (no smaller than 3mm [1/8"]) to reduce the risk of obstruction. Low Risk - Falling Objects Hazard Falling objects hazard if items are left on the top panel. Mitigation High Risk - Crush Hazard See general mitigations. Crush hazard between the cabinet top and the base panel when the mechanism is opening. Mitigation Box enclosure Keep all shadow gaps to a minimum (no smaller than 3mm [1/8”]) to reduce the risk of obstruction. Cabinet Low Risk - Cable Snagging Hazard Cables could be snagged if not properly managed through and around the mechanism, High Risk - Crush Hazard causing damage to the mechanism and Crush hazard below the mechanism when electronics. mechanism is closing. Mitigation Mitigation Ensure sufficient cable slack is allowed around Ensure area below the mechanism is kept clear movement joints to prevent stretching and/ or at all times when the mechanism is being used. damage to the cables and/ or mechanism. If installing or maintaining the mechanism do so
with the mechanism turned off. CONSIDERATIONS SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 1 FUTUREAUTOMATION