Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Future Automation SPS-V-5 technical sheet

Page 1 of 12100%
Text of this document12 pages · 2,734 words

Page 1

SPS-V-5 SLIDING PANEL MECHANISM - VERTICAL TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

SPS-V-5 SLIDING PANEL MECHANISM - VERTICAL SPS-V - VERTICAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN HEIGHT MAX SCREEN HEIGHT SPS-V-5 Vertical - Single Panel 700 [27 9/16"] 800 [31 1/2"] SPS-V-6 Vertical - Single Panel 801 [31 9/16"] 950 [37 3/8"] SPS-V-7 Vertical - Single Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-V-8 Vertical - Single Panel 1101[ 43 3/8""] 1250[ 49 3/16"] SPS-VS - VERTICAL SPLIT - DOUBLE PANEL SPS-VS-5 Vertical - Double Splitting Panel 700 [27 9/16"] 800 [31 1/2"] SPS-VS-6 Vertical - Double Splitting Panel 801 [31 9/16"] 950 [37 3/8"] SPS-VS-7 Vertical - Double Splitting Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-VS-8 Vertical - Double Splitting Panel 1101[ 43 3/8""] 1250[ 49 3/16"] SPS-HZ - HORIZONTAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN WIDTH MAX SCREEN WIDTH SPS-HZ-6 Horizontal - Single Panel 1400 [55 1/8"] 1600 [63"] SPS-HZ-7 Horizontal - Single Panel 1601 [63 1/16""] 1850 [72 13/16"] SPS-HZ-8 Horizontal - Single Panel 1851 [72 7/8"] 2100 [82 11/16"] SPS-HZS - HORIZONTAL SPLIT- DOUBLE PANEL SPS-HZS-6 Horizontal - Double Splitting Panel 1400 [55 1/8"] 1600 [63"] SPS-HZS-7 Horizontal - Double Splitting Panel 1601 [63 1/16""] 1850 [72 13/16"] SPS-HZS-8 Horizontal - Double Splitting Panel 1851 [72 7/8"] 2100 [82 11/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

SPS-V-5 SLIDING PANEL MECHANISM - VERTICAL 1. Panel Closed 2. Panel Retracts SPECIFICATION MEASUREMENTS Minimum Screen Height 700 [27 9/16"] Maximum Screen Height 800 [31 1/2"] Minimum Screen Width 1100 [43 5/16"] Maximum Screen Width 1600 [63"] Maximum Moving Panel Weight 40Kg (88lbs) Maximum Screen Weight 100Kg (220lbs) Total Mechanism Weight TBC Packaging Dimensions (LxWxH) TBC Shipping Weight TBC 3. Panel Lifts 4. Screen Advances Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption Max. 120W Power Consumption Standby 3W Mounting Patterns Supported VESA 200 - 800 W x 200 - 600 H Control Options IR Remote, RS232, Contact Closure Product Options / Features QA2 pairing option Package Contents Mechanism, IR remote control, Bolt Pack Marine Suitable Yes (Indoor) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

To determine the cavity height use the following SPS-V-5 formula: SECTION A-A SLIDING PANEL MECHANISM - VERTICAL Cavity Height = (2 x Screen Height) + 80 SECTION B-B Maximum Screen Height If the cavity height is larger than the min. cavity height CABINET DIMENSIONS - WIDTH AND HEIGHT shown below that is your cavity height if not use the 5 5/16" 5 5/16" 135 135 min. cavity height. Screen Height Install Height B SECTION B-B Internal Cabinet Width = Screen Width + 280 SPS-V SizeScreen HeightInstal Height Minimum Screen Height 700 [27 9/16"] 710 [27 15/16"] 1610 [63 3/8"] 650 [25 9/16"] 710 [27 15/16"]1610 [63 3/8"] 50 800 [31 1/2"] (2 x Screen Height) + 190 710 [27 15/16"] Size 5 1 15/16" Clearance 710 [27 15/16"] 800 [31 1/2"](2 x Screen Height) + 190 Screen Width Install width 800 [31 1/2"] 785 [30 7/8"]1760 [69 5/16"] 1100 [43 5/16"] 1600 [63"] Screen Width + 280 785 [30 7/8"] 950 [37 3/8"](2 x Screen Height) + 190 Size 6 Screen Height Moving Panel Height = 950 [37 3/8"] 960 [37 13/16"]2110 [83 1/16"] 5 5/16" 5 5/16" A A Screen Height 135 135 SECTION A-A 960 [37 13/16"] 1100[ 43 5/16"] (2 x Screen Height) + 190 Size 7 Moving Panel Height = Internal Cabinet Width = Screen Width + 280 B 1100[ 43 5/16"] 1030 [40 9/16"]2250 [88 9/16"] Opening Width = Screen Width +10 1030 [40 9/16"] 1250[ 49 3/16"] (2 x Screen Height) + 190 Size 8

Opening Height = Screen Height +10

1590 1590 62 5/8" 62 5/8" 20 13/16" 20

13/16" Mechanism Height Mechanism Height SPS-V SizeScreen HeightInstal Height

Install Height = (2 x Screen Height) + 190 650 [25 9/16"] 710 [27 15/16"]1610 [63 3/8"] B Size 5 Minimum Install Height = 1610 [63 3/8"] 710 [27 15/16"] 800 [31 1/2"](2 x Screen Height) + 190 A A The SPS-V will always require 110mm [4 5/16"] below the opening. Opening Height 800 [31 1/2"] 785 [30 7/8"]1760 [69 5/16"] Opening Height The remaining height required is determined either by the size of the height of

the screen or the height of the mechanism. 785 [30 7/8"] 950 [37 3/8"](2 x Screen Height) + 190 Size 6

110 The install height is calculated be the following formula (2 x Screen Height) + 190. 4 5/16"

If this comes out under the mechanism height the mechanism height needs to 110 4 5/16" be used instead. 950 [37 3/8"] 960 [37 13/16"]2110 [83 1/16"]

Opening Width = Opening Height = Screen Height +10 Screen Width +10 960 [37 13/16"] 1100[ 43 5/16"] (2 x Screen Height) + 190 Size 7 TECHNICAL SHEET 1100[ 43 5/16"] 1030 [40 9/16"]2250 [88 9/16"] UK +44 (0) 1438 833577 US +1 (603) 742 9181 B ISSUE 002 WWW NET . . SHEET 4 FUTUREAUTOMATION 1030 [40 9/16"] 1250[ 49 3/16"] (2 x Screen Height) + 190 Size 8

Page 5

In order to calculate the positioning of the mechanism within the cabinetwork the following calculation is used: a = ( X + Y ) - 30mm X = Thickness of front panel & battening Y = Thickness of moving panel SPS-V-5 a = Distance of mechanism mounting plate to finish serface of cabinet work. The front panel work and support batten (X) must be no thicker than 50mm [1 15/16"]. The front panel work can be no more than 20mm thicker than the moving panel. If the front panel and batten has to be more than 20mm thicker, the moving panel needs to be packed out inorder to keep this difference SLIDING PANEL MECHANISM - VERTICAL FRONT PANEL AND SUPPORTS DEPTH 20mm. This new total thickness needs to be used as Y not just the panel thickness. The moving panel retracts back by 65mm [2 9/16"] Example : A 30mm [1 3/16”] thick front panel (X) and a 40mm [1 9/16”] moving panel (Y) ( X + Y ) - 30 = a before rising. For this reason it is advised the front ( 30 + 40 ) - 30 = 40 The mechanism needs to be positioned 40mm from the outer edge of the front panel. MECHANISM POSITIONING Screen - IN panel work and support batten is no more than Screen - IN 50mm [1 15/16"] thick to give 15mm [9/16"] clearance. Moving Panels greater than 32mm [1 1/4] thick Moving Panels less than 32mm [1 1/4] thick Thicker panels are possible, but will add to the cabinet A For panels thicker that 32mm [1 1/4"] move the mechanism back by the If the moving panel is up to 32mm [1 1/4"] thick then mount the mechanism flush to the depth and require customisation to the mechanism increase in thickness. inside of the front panel as shown. design. For example: a 38mm [1 1/2"] thick moving panel needs the mechanism If the front panel and batten has to be more than 20mm thicker than the moving panel, mounted 6mm [1/4"] away from the inside of the front panel (and battens). the moving panel needs to be packed out in order to keep this difference 20mm. This total thickness of the panel and the packer needs to be used as the new moving panel thickness. 1 1/2" 1 1/4" max. 38 32 max. A Moving Panel thickness Moving Panel Thickness A Front panel Front panel A and battening and battening Mechanism needs to be positioned so the mount brackets are flush with the inside face of the front panel and battening. Not touching Touching Spacing required No gap required F F MOVING PANEL DEPTH For moving panels thicker than 30mm [1 3/16”] move the mechanism back by the extras 1/4" mount plate mount plate 6 thickness above 30mm [1 3/16”]. Example : For a 40mm [1 9/16”] panel move the mechanism 10mm [3/8”] back. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 5 FUTUREAUTOMATION

Page 6

SPS-V-5 SLIDING PANEL MECHANISM - VERTICAL Screen - IN Screen - OUT CABINET DIMENSIONS - DEPTH Moving Panel D Thickness A cabinet depth of 235mm [9 1/4"] allows for a maximum screen depth of 60mm [2 3/8"]. A 1 15/16" Cabinet depth needs to be increased if: 50 • Moving panel depth is greater than 32mm [1 1/4"]. Max. Front Panel • Screen depth is greater than 60mm [2 3/8"]. and Batten Thickness 2 9/16" 65 If the Moving panel thickness is greater than 32mm [1 1/4"], the Retract internal cabinet depth will need to be increased by the difference i.e. a 52mm [2 1/16"] thick panel requires the cabinet depth to be increased by 20mm to 255mm [10 1/16"]. DETAIL D If the screen thickness is greater than 60mm [2 3/8"], the internal 2 9/16" 65 cabinet depth will need to be increased i.e. a 100mm [3 15/16"] thick A Max. Retract screen requires the cabinet depth to be increased by 40mm to 275mm [10 13/16"]. A The moving panel can retract up to 65mm [2 9/16"] Cabinet depth can be reduced if the screen thickness is less than before rising. For this reason it is advised the front 60mm [2 3/8"]. Minimum cabinet depth possible is 205mm [8 1/16"]. panel work and support battens are no more than 50mm [1 15/16"] thick to give 15mm [9/16"] clearance. Recommended batten to support front panel above opening A Recommended batten to support front panel below opening 9 1/4" 235 TECHNICAL SHEET Internal UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 Cabinet Depth WWW NET . . SHEET 6 FUTUREAUTOMATION

Page 7

SPS-V-5 SLIDING PANEL MECHANISM - VERTICAL CABINET DETAILS INVERTED Screen Height Install Height 710 [27 15/16"] 1610 [63 3/8"] 700 [27 9/16"]

B 800 [31 1/2"] (2 x Screen Height) + 190 710 [27 15/16"] 110 4 5/16"

Screen Width Install width A A 1100 [43 5/16"] 1600 [63"] Screen Width + 280 The SPS-V can be inverted so the panel retracts then drops. The Opening Height

mechanism used is the same as in the retract and rise configuration, the Opening Width = mechanism is just rotated through 180 . Opening Height = Screen Height +10 20 Screen Width +10 13/16"

1590 1. Panel Retracts 2. Panel Drops 62 5/8" Mechanism Height Minimum Install Height = 1610 [63 3/8"] Install Height = (2 x Screen Height) + 190 Screen Height Opening Height = Screen Height +10 Moving Panel Height = Opening Width = 50 Screen Width +10 B 1 15/16" Clearance SECTION B-B The SPS-V will always require 110mm [4 5/16"] below the opening. Internal Cabinet Width = Screen Width + 280 5 5/16" 5 5/16" The remaining height required is determined either by the size of the height of 135 135 the screen or the height of the mechanism. The install height is calculated be the following formula (2 x Screen Height) + 190. If this comes out under the mechanism height the mechanism height needs to TECHNICAL SHEET be used instead. UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 SECTION A-A WWW NET . . SHEET 7 FUTUREAUTOMATION

Page 8

SPS-V-5 A SLIDING PANEL MECHANISM - VERTICAL ADVANCE - SERVICE ADVANCE - IN ADVANCE - OUT AB - ADVANCE BRACKET The Advance Bracket has a service mode that can be used during installation and servicing of the mechanism and the screen. This allows the screen to be pulled out from the wall to provide access to rear of the screen and inside the mechanism during A fitting. 3 15/16" A 100 43 5/16" 1100 A A 24 7/16" 622 Max Mount Height A VESA 200 [7 7/8"] TO 800 [31 1/2"] VESA 100 [3 15/16"] TO 600 [23 5/8"] 31 1/2" 800 Max Mount Width 20 1/16" 3 15/16" 510 100 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 NET WWW . . SHEET 8 FUTUREAUTOMATION

Page 9

SPS-V-5 SLIDING PANEL MECHANISM - VERTICAL CABINET DETAILS & ACCESS The SPS mechanism requires certain access for installation and servicing. For installation, the top panel must be removable to provide access to all the fixing points. Top Panel (removable for installation) For servicing, the best option is to have the panels to the left and right of the opening on hinges. This will provide enough access to everything that will need to be serviced and maintained. Alternatively, the side panels could be made to be easily removable on suitable catches / fixings. The Moving Panel Mechanism mounts to the side walls of the cabinet, and the Advance Bracket mounts to the back of the cabinet. It is essential that these surfaces can take the weight of the mechanism, moving panel and screen. Advance Bracket The mechanism is supplied with a control box on a 3m [10'] flying lead. This must be fitted in an easily accessible location. This will be the first item to be checked if there is an issue with the mechanism. Mains power and control connections (IR sensor / receiver, contact closure, RS232) are all made at the control box. Hinging side panel (removable for service & maintenance) Moving panel bracket Hinging side panel (removable for service & maintenance) Moving Panel Mechanism Motor Mechanism Cables Moving panel bracket Power Cables Control box wiring loom must be routed to the bottom left corner of the cabinet Telescopic Drive shaft To Mains Power TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 9 FUTUREAUTOMATION

Page 10

SPS-V-5 SLIDING PANEL MECHANISM - VERTICAL CONTROL BOX

V 207 8 1/8"

RS232 PORT IR OUTPUT INDICATOR LED CONTACT CLOSURE PORT IR LEAD INPUT EMERGENCY STOP 3.5mm [0.14"] JACK CONNECTOR max CABLE LOOM 20 LENGTH APPROX 13/16" 118 1/8" 8 CORE CABLE 3000 SPS SWITCHES 10mm [3/8"] dia. EU SPEC: 0.5mm² US SPEC: 20AWG 1/4"

5/16" 4 CORE CABLE

2 CORE CABLE SPS MOTOR 52 SPS MOTOR 2 1/16" 10mm [0.4"] dia. MAINS INPUT

10mm [3/8"] dia. EU SPEC: 0.75mm² EU SPEC: 4mm² 8 CORE CABLE US SPEC: 18AWG 5 5 7/8" US SPEC: 12AWG ADVANCE BRACKET 3/16" 150

10mm [3/8"] dia. EU SPEC: 0.5mm² US SPEC: 20AWG NOTES • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 10 FUTUREAUTOMATION

Page 11

SPS-V-5 SLIDING PANEL MECHANISM - VERTICAL INSTALLATION OVERVIEW Up Switch 3. Run the mechanism, adjust the up switch so that the carriages travels the height of the moving panel + 25mm [1"]. 1. Mount the mechanism side Rear View C channels to the side walls of the cabinet. Up Switch Adjustment Loosen the bolt and slide the switch striker to the desired position. Ensure the bolt is Down Switch tightened after adjustment. Switch Striker 2. Install the telescopic drive shaft between both sides of the mechanism. Ensure that the moving panel brackets are at the same height. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 11 FUTUREAUTOMATION

Page 12

SPS-V-5 SLIDING PANEL MECHANISM - VERTICAL INSTALLATION OVERVIEW 4. Mount the Panel Brackets to the rear of the moving panel as 5. Mount the moving panel back onto the mechanism, use the slots in the dimensioned below. mount brackets to align the panel and get it into the desired position. 3 11/16" 94 Rear View of moving panel 3 11/16" 94 4 5/16" 110 Moving panel bracket 4 5/16" 110 Recommended to use 5mm shims to align the moving panel with the base of the aperture. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 12 FUTUREAUTOMATION

Need assistance or looking to source this item?