Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Future Automation SPS-HZS-7 technical sheet

Page 1 of 11100%
Text of this document11 pages · 2,450 words

Page 1

SPS-HZS-7 SLIDING PANEL MECHANISM - HORIZONTAL SPLIT TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

SPS-HZS-7 SLIDING PANEL MECHANISM - HORIZONTAL SPLIT SPS-V - VERTICAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN HEIGHT MAX SCREEN HEIGHT SPS-V-5 Vertical - Single Panel 700 [27 9/16"] 800 [31 1/2"] SPS-V-6 Vertical - Single Panel 801 [31 9/16"] 950 [37 3/8"] SPS-V-7 Vertical - Single Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-V-8 Vertical - Single Panel 1101[ 43 3/8"] 1250[ 49 3/16"] SPS-VS - VERTICAL SPLIT - DOUBLE PANEL SPS-VS-5 Vertical - Double Splitting Panel 700 [27 9/16"] 800 [31 1/2"] SPS-VS-6 Vertical - Double Splitting Panel 801 [31 9/16"] 950 [37 3/8"] SPS-VS-7 Vertical - Double Splitting Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-VS-8 Vertical - Double Splitting Panel 1101[ 43 3/8"] 1250[ 49 3/16"] SPS-HZ - HORIZONTAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN WIDTH MAX SCREEN WIDTH SPS-HZ-6 Horizontal - Single Panel 1400 [55 1/8"] 1600 [63"] SPS-HZ-7 Horizontal - Single Panel 1601 [63 1/16"] 1850 [72 13/16"] SPS-HZ-8 Horizontal - Single Panel 1851 [72 7/8"] 2100 [82 11/16"] SPS-HZS - HORIZONTAL SPLIT- DOUBLE PANEL SPS-HZS-6 Horizontal - Double Splitting Panel 1400 [55 1/8"] 1600 [63"] SPS-HZS-7 Horizontal - Double Splitting Panel 1601 [63 1/16"] 1850 [72 13/16"] SPS-HZS-8 Horizontal - Double Splitting Panel 1851 [72 7/8"] 2100 [82 11/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

SPS-HZS-7 SLIDING PANEL MECHANISM - HORIZONTAL SPLIT 1. Panel Closed 2. Panel Retracts SPECIFICATION MEASUREMENTS Minimum Screen Width 1601 [63 1/16"] Maximum Screen Width 1850 [72 13/16"] Minimum Screen Height 850 [33 7/16"] Maximum Screen Height 1250 [49 3/16"] Maximum Moving Panel Weight 15Kg (33lbs) (Per Panel) Maximum Screen Weight 100Kg (220lbs) Total Mechanism Weight TBC Packaging Dimensions (LxWxH) TBC Shipping Weight TBC 3. Panel Slides 4. Screen Advances Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption Max. 120W Power Consumption Standby 3W Mounting Patterns Supported VESA 200 - 800 W x 200 - 600 H Control Options IR Remote, RS232, Contact Closure Product Options / Features QA2 pairing option Package Contents Mechanism, IR remote control, Bolt Pack Marine Suitable Yes (Indoor) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

• The Screen Advance Heavy bracket can SPS-HZS-7 accommodate a screen bolt pattern up 63 3/4" to: VESA 800x600. Up to M8 diameter fixings. 1620 • The bracket can be positioned within the SLIDING PANEL MECHANISM - HORIZONTAL SPLIT opening as required based on TV VESA 61 7/16" A 1560 mount location. CABINET DIMENSIONS - WIDTH AND HEIGHT 6 5/16" B B 160 Width Left of Width Right of Screen Width Instal Width 3 1/8" Screen Center Line Screen Center Line 80 63 1/16" 72 13/16" 6 5/16" 3 1/8" 3 1/8" The SPS-HZ will always require 110mm [4 5/16"] to the side the opening oposite 1601 1850 (2 x Screen) + 160 Screen + 80 Screen + 80 72 13/16" Opening Height = the slide direction. 1850 Screen Height +10 58 1/4" Screen Height Install Height Opening Width = The remaining height required is determined by the width of the screen being 1480 Screen Width +10 installed in the mechanism. 33 7/16" 49 3/16" 11" 63 1/16" 850 1250 Screen Height + 280 1601 The install height is calculated be the following formula (2 x Screen Height) + 190. If this comes out under the mechanism height the mechanism height needs to be used instead. A 126" 33 7/16" SECTION B-B 3200 850 Minimum Screen Height Mechanism Width

49 3/16" A 1250 135 5 5/16"

11" SECTION A-A 280 C C Width Left of Screen = Screen Width + 80 Width Right of Screen = Screen Width + 80 B B L L Screen C SECTION B-B L Maximum Screen Height Instal Width = (2 x Screen Width) + 160 Opening Height C C Width left of Screen = Screen Width + 80 Width Right of Screen = Screen Width + 80 L L Opening Width = Screen Width +10

135 5 5/16"

Screen Opening Height = Moving Panel Width = Moving Panel Width = C L Screen Height +10 (Screen Width - 5) / 2 (Screen Width - 5) / 2 1 15/16" 1 15/16" Opening Width A 50 50 13/16" 13/16" Clearance Clearance 20 20 SECTION A-A TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 4 FUTUREAUTOMATION

Page 5

In order to calculate the positioning of the mechanism within the cabinetwork the following calculation is used: a = ( X + Y ) - 30mm X = Thickness of front panel & battening Y = Thickness of moving panel SPS-HZS-7 a = Distance of mechanism mounting plate to finish serface of cabinet work. The front panel work and support batten (X) must be no thicker than 50mm [1 15/16"]. The front panel work can be no more than 20mm thicker than the moving panel. If the front panel and batten has to be more than 20mm thicker, the moving panel needs to be packed out inorder to keep this difference SLIDING PANEL MECHANISM - HORIZONTAL SPLIT FRONT PANEL AND SUPPORTS DEPTH 20mm. This new total thickness needs to be used as Y not just the panel thickness. The moving panel retracts back by 65mm [2 9/16"] Example : A 30mm [1 3/16”] thick front panel (X) and a 40mm [1 9/16”] moving panel (Y) ( X + Y ) - 30 = a before rising. For this reason it is advised the front ( 30 + 40 ) - 30 = 40 The mechanism needs to be positioned 40mm from the outer edge of the front panel. MECHANISM POSITIONING panel work and support batten is no more than 50mm [1 15/16"] thick to give 15mm [9/16"] clearance. Moving Panels greater than 32mm [1 1/4] thick Moving Panels less than 32mm [1 1/4] thick Thicker panels are possible, but will add to the cabinet For panels thicker that 32mm [1 1/4"] move the mechanism back by the If the moving panel is up to 32mm [1 1/4"] thick then mount the mechanism flush to the depth and require customisation to the mechanism increase in thickness. inside of the front panel as shown. design. For example: a 38mm [1 1/2"] thick moving panel needs the mechanism If the front panel and batten has to be more than 20mm thicker than the moving panel, AA mounted 6mm [1/4"] away from the inside of the front panel (and battens). the moving panel needs to be packed out in order to keep this difference 20mm. This total thickness of the panel and the packer needs to be used as the new moving panel thickness. AA 1 1/2" 38 1 1/4" max. Moving Panel 32 max. thickness Moving Panel Thickness mount plate mount plate Mechanism needs to be positioned so the mount 1/4" brackets are flush with the inside face of the front 6 panel and battening. MOVING PANEL DEPTH Front panel Front panel Not touching For moving panels thicker than 30mm [1 3/16”] Touching and battening and battening Spacing required move the mechanism back by the extras No gap required thickness above 30mm [1 3/16”]. Example : For a 40mm [1 9/16”] panel move the mechanism 10mm [3/8”] back. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 5 FUTUREAUTOMATION

Page 6

SPS-HZS-7 SLIDING PANEL MECHANISM - HORIZONTAL SPLIT CABINET DIMENSIONS - DEPTH The moving panel can retract up to 65mm [2 9/16"] The minimum depth 235mm [9 1/4"] allows for a maximum screen depth of 60mm [2 3/8"]. Moving Panel before rising. For this reason it is advised the front Thickness panel work and support battens are no more than Cabinet depth needs to be increased if: 50mm [1 15/16"] thick to give 15mm [9/16"] clearance. • Moving panel depth is greater than 32mm [1 1/4"]. • Screen depth is greater than 60mm [2 3/8"]. If the Moving panel thickness is greater than 32mm [1 1/4"], the internal cabinet depth will need to be increased by the difference i.e. a 52mm [2 1/16"] thick panel requires the DETAIL D cabinet depth to be increased by 20mm to 255mm [10 1/16"]. AA If the screen thickness is greater than 60mm [2 3/8"], the internal cabinet depth will need 1 15/16" to be increased i.e. a 100mm [3 15/16"] thick screen requires the cabinet depth to be 50 2 9/16" increased by 40mm to 275mm [10 13/16"]. 65 Max. Front Panel Max. Retract and Batton Thickness The minimum depth 235mm [9 1/4"] allows for a maximum screen Screen - IN depth of 60mm [2 3/8"]. AA Screens with a greater thickness will cause the cabinet depth to increase i.e. a 100mm [3 15/16"] thick screen will require a cabinet of 275mm [10 13/16""]. Screens thinner than 65mm [2 9/16"] must be in the minimum 240mm [9 7/16"] cabinet. Recomended battens to support Recomended battens to support front panel above opening front panel above opening Screen - OUT The moving panels retract back by 65mm [2 9/16"] before sliding. For this reason it is advised the front panel work and support batten is no more than 9 1/4" 50mm [1 15/16"] thick to give 15mm [9/16"] clearance. 235 Minimum Internal Thicker panels are possible, but will add to the cabinet Cabinet Depth depth and require customisation to the mechanism design. 13/16" 20 D Front Panel Thickness TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 6 FUTUREAUTOMATION

Page 7

SPS-HZS-7 SLIDING PANEL MECHANISM - HORIZONTAL SPLIT

AB - ADVANCE BRACKET AA 100 3 15/16" ADVANCE - IN

The Advance Bracket has a service mode that can be used during installation and servicing of the mechanism and the screen. This allows the screen to be pulled out from the wall to provide access to rear of the screen and inside the mechanism during fitting. 3 15/16" 100 AA ADVANCE - OUT 43 5/16" 1100 AA 24 7/16" 622

Max Mount Height 510 ADVANCE - SERVICE 20 1/16"

31 1/2" 800 Max Mount Width TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 7 FUTUREAUTOMATION

Page 8

SPS-HZS-7 SLIDING PANEL MECHANISM - HORIZONTAL SPLIT Removable Right Side Panel CABINET DETAILING & ACCESS The SPS mechanism requires certain access for installation and servicing. For installation, the top panel must be removable to provide access to all the fixing points. Hinging top panel For servicing, the best option is to have the panels to the left and right of the opening on hinges. This will provide enough access to everything that will need to be serviced and maintained. Alternatively, the side panels could be made to be easily removable on suitable catches / fixings. Moving Panel Bracket he Moving Panel Mechanism mounts to the side walls of the cabinet, and the Advance Bracket mounts to the back of the cabinet. It is essential that these surfaces can take the weight of the mechanism, moving panel and screen. Motor The mechanism is supplied with a control box on a 3m [10'] flying lead. This must be fitted in an easily accessible location. This will be the first item to be checked if there is an issue with the mechanism. Mains power and control connections (IR sensor / receiver, contact closure, RS232) are all made at the control box. Moving Panel Bracket To Mains Power Hinging bottom panel Mechanism Cables Power Cables Control box wiring loom must be routed to the bottom right Side Panel corner of the cabinet. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 8 FUTUREAUTOMATION

Page 9

SPS-HZS-7 SLIDING PANEL MECHANISM - HORIZONTAL SPLIT CONTROL BOX

207 8 1/8"

HZ RS232 PORT IR OUTPUT INDICATOR LED CONTACT CLOSURE PORT IR LEAD INPUT EMERGENCY STOP 3.5mm [0.14"] JACK max CONNECTOR CABLE LOOM 20 LENGTH APPROX 13/16" 118 1/8" 3000 8 CORE CABLE SPS SWITCHES 10mm [3/8"] dia. 1/4" EU SPEC: 0.5mm²

US SPEC: 20AWG 8

5/16" 4 CORE CABLE

SPS MOTOR 52 2 1/16" 10mm [0.4"] dia.

2 CORE CABLE EU SPEC: 0.75mm² SPS MOTOR US SPEC: 18AWG 5 5 7/8" MAINS INPUT 10mm [3/8"] dia. 3/16" 150

EU SPEC: 2.5mm² 8 CORE CABLE US SPEC: 14AWG ADVANCE BRACKET 10mm [3/8"] dia. EU SPEC: 0.5mm² NOTES US SPEC: 20AWG • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 9 FUTUREAUTOMATION

Page 10

SPS-HZS-7 SLIDING PANEL MECHANISM - HORIZONTAL SPLIT INSTALLATION OVERVIEW 2. Install the telescopic drive shaft between both sides of the mechanism. Ensure that the moving panel brackets are at the same height. Rear View Up Switch Adjustment Loosen Bolt and slide the switch striker to desired position. Ensure C bolt is tightened after adjustment. Switch Striker 3. Run the mechanism, adjust the up switch so that the carriages move the height of you panel + 25mm [1"]. Down Switch 1. Mount the mechanism side channels to the side walls of the cabinet. Up Switch TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 10 FUTUREAUTOMATION

Page 11

SPS-HZS-7 SLIDING PANEL MECHANISM - HORIZONTAL SPLIT INSTALLATION OVERVIEW 4. Mount the Panel Brackets to the rear of the moving panel as 5. Mount the moving panel back onto the mechanism, use the slots in the dimensioned below. mount brackets to align the panel and get it into the desired position. 3 11/16" 94 3 11/16" 3 11/16" 94 Rear View of moving panel 94 Recommended to use 5mm

shims to align the moving panel with the side of the aperture. 110 110 4 5/16" 4 5/16"

3 11/16" 94 1 9/16" 40 1 9/16" 40 1 9/16" 40 1 9/16" Recommended to use 5mm 40 shims to align the left and right 3 11/16" 94 moving panels. 3 11/16" 94 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 11 FUTUREAUTOMATION

Need assistance or looking to source this item?