SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL SPS-V - VERTICAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN HEIGHT MAX SCREEN HEIGHT SPS-V-5 Vertical - Single Panel 700 [27 9/16"] 800 [31 1/2"] SPS-V-6 Vertical - Single Panel 801 [31 9/16"] 950 [37 3/8"] SPS-V-7 Vertical - Single Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-V-8 Vertical - Single Panel 1101[ 43 3/8""] 1250[ 49 3/16"] SPS-VS - VERTICAL SPLIT - DOUBLE PANEL SPS-VS-5 Vertical - Double Splitting Panel 700 [27 9/16"] 800 [31 1/2"] SPS-VS-6 Vertical - Double Splitting Panel 801 [31 9/16"] 950 [37 3/8"] SPS-VS-7 Vertical - Double Splitting Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-VS-8 Vertical - Double Splitting Panel 1101[ 43 3/8""] 1250[ 49 3/16"] SPS-HZ - HORIZONTAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN WIDTH MAX SCREEN WIDTH SPS-HZ-6 Horizontal - Single Panel 1400 [55 1/8"] 1600 [63"] SPS-HZ-7 Horizontal - Single Panel 1601 [63 1/16""] 1850 [72 13/16"] SPS-HZ-8 Horizontal - Single Panel 1851 [72 7/8"] 2100 [82 11/16"] SPS-HZS - HORIZONTAL SPLIT- DOUBLE PANEL SPS-HZS-6 Horizontal - Double Splitting Panel 1400 [55 1/8"] 1600 [63"] SPS-HZS-7 Horizontal - Double Splitting Panel 1601 [63 1/16""] 1850 [72 13/16"] SPS-HZS-8 Horizontal - Double Splitting Panel 1851 [72 7/8"] 2100 [82 11/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL 1. Panel Closed 2. Panel Retracts SPECIFICATION MEASUREMENTS Minimum Screen Width 1400 [55 1/8"] Maximum Screen Width 1600 [63"] Minimum Screen Height 750 [29 1/2"] Maximum Screen Height 1050 [41 5/16"] Maximum Moving Panel Weight 15Kg (33lbs) Maximum Screen Weight 80Kg (176lbs) Total Mechanism Weight TBC Packaging Dimensions (LxWxH) TBC Shipping Weight TBC 3. Panel Slides 4. Screen Advances Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption Max. 120W Power Consumption Standby 3W Mounting Patterns Supported VESA 400, 300, 200 W x 400, 300, 200 H Control Options IR Remote, Contact Closure Product Options / Features AB pairing option Package Contents Mechanism, IR remote control, Bolt Pack Marine Suitable Yes (Indoor) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
To determin the cavity height use the folowing • The Screen Advance Heavy bracket can SPS-HZ-6 - QA2-60 formula: accommodate a screen bolt pattern up to: VESA 800x600. Up to M8 diameter fixings. SLIDING PANEL MECHANISM - HORIZONTAL Cavity Height = (2 x Screen Height) + 80 • The bracket can be positioned within the opening as required based on TV VESA A If the cavity height is larger than the min. cavity height mount location. CABINET DIMENSIONS - WIDTH AND HEIGHT shown below that is your cavity height if not use the B B min. cavity height. Screen Width Install Width SPS-V SizeScreen HeightInstal Height 1600 [63"] (2 x Screen Width) + 190 1400 [55 1/8"] 1610 [63 3/8"] Opening Height = Size 5 Screen Height +10 (2 x Screen Height) + 190 Screen Height Install Height 750 [29 1/2"] 1050 [41 5/16"] Screen Height + 280 Opening Width = A 1760 [69 5/16"] Screen Width +10 Size 6(2 x Screen Height) + 190 A 2110 [83 1/16"] B B 105 7/8" SECTION B-B 2690 Size 7(2 x Screen Height) + 190 Minimum Screen Height Mechanism Width 5 5/16"135 SECTION A-A
2250 [88 9/16"] Size 8(2 x Screen Height) + 190 Opening Width = Screen Width +10 Opening Width Moving Panel Width = Screen Width 1 15/16" 50 4 5/16" 13/16" SPS-V SizeScreen HeightInstal Height 110 Clearance Opening Height 20 1610 [63 3/8"] Opening Height = 105 7/8" Size 5 Screen Height +10 2690 SECTION B-B (2 x Screen Height) + 190 Mechanism Width Maximum Screen Height 5 5/16"135 A
1760 [69 5/16"] The SPS-HZ will always require 110mm [4 5/16"] to the side the opening oposite the slide direction. Size 6(2 x Screen Height) + 190 The remaining height required is determined by the width of the screen being Install Width = (2 x Screen Width) + 190 installed in the mechanism. 2110 [83 1/16"] SECTION A-A The install height is calculated be the following formula (2 x Screen Height) + 190. Size 7(2 x Screen Height) + 190 If this comes out under the mechanism height the mechanism height needs to be used instead. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 2250 [88 9/16"] WWW NET . . SHEET 4 FUTUREAUTOMATION Size 8(2 x Screen Height) + 190
Page 5
SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL AA CABINET DIMENSIONS - DEPTH 1 3/16" 30 The moving panel retracts back by 65mm [2 9/16"] The minimum depth of 245mm [9 5/8"] allows for a maximum Moving Panel before Sliding. For this reason it is advised the front screen depth of 30mm [1 3/16"]. Thickness panel work and support batten is no more than 50mm [1 15/16"] thick to give 15mm [9/16"] clearance. Screens with a greater thickness will need the cabinet depth to increase i.e. a 100mm [3 15/16"] thick screen will require a cabinet Thicker panels are possible, but will add to the cabinet of 315mm [12"]. depth and require customisation to the mechanism design. Screens thinner than 30mm [1 3/16"] must still use the minimum DETAIL D 245mm [12 3/8"] cabinet depth. SCALE 1 : 3 AA 2 9/16" 1 15/16" 65 50 Retract Max. Front Panel and Batton Thickness Screen - IN 9 5/8" Recomended battens to support 245 front panel above opening Minimum Internal Cabinet Depth Screen - OUT 13/16" D 20 Front Panel Thickness TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 5 FUTUREAUTOMATION
Page 6
SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL A CABINET DETAILS - RIGHT SLIDE Screen Width Install Width 1400 [55 1/8"] 1600 [63"] (2 x Screen Width) + 190 Opening Width = Screen Width +10 Screen Height Install Height Opening Height = Screen Height +10 750 [29 1/2"] 1050 [41 5/16"] Screen Height + 280 The SPS-HZ can be inverted so the panel slides right instead. The mechanism used is the A same as in the original orientation, the mechanism is just rotated through 180 . 1. Panel Retracts 2. Panel Slides Right A B B A A A 5 5/16"135
SECTION B-B Maximum Screen Height 1 15/16" 50 4 5/16" 13/16" 110 20 Clearance Opening Width Moving Panel Width = Screen Height Internal Cabinet Height = Screen Width + 280 5 5/16"135
105 7/8" 2690 Mechanism Width SECTION A-A Install Width = (2 x Screen Height) + 190 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 6 FUTUREAUTOMATION
Page 7
SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL 140 DEPTH OVERWRITTEN ADVANCE - IN 5 1/2" QA2-60 - QUAD ARM The Quad Arm has a service mode that can be used during installation and servicing of the mechanism and the screen. This allows the screen to be advanced out from the wall to ADVANCE - OUT provide access to rear of the screen and inside the mechanism AA during fitting. 5 1/2"140 ADVANCE - SERVICE AA AA 36 3/16"919
ADVANCE - SERVICE AA 27 9/16"700Max Mount Height 23 5/8" 600 Maximum QA2 swivel is 75 . 40° Max Mount Width However depending on the screen and cabinet depth this will need to be reduced to prevent the screen being obscured by the cabinet. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 7 FUTUREAUTOMATION
Page 8
SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL CABINET DETAILING & ACCESS The SPS mechanism requires certain access for installation and to be serviced. Side Panel (removable for installation) For installation the side panel must be removable to provide access to all the fixing points of the SPS mechanism. For servicing the best option is to have the areas to the top and bottom of the opening on hinges. This will provide enough access Hinging top panel to everything that will be needed to service and maintain the (removable for service & mechanism. Alternatively these panels could be made to be easily maintenance) removable on suitable catches / fixings. The Moving Panel Mechanism mounts to the top and bottom walls Moving Panel Bracket of the cabinet, and the Advance Bracket mounts to the back of the cabinet. It is essential that these surfaces can take the weight of the mechanism, moving panel and screen. QA-60 The mechanism is supplied with a control box on a 3m [10'] flying lead. This must be fitted in an easily accessible location. This will be the first item to be checked if there is an issue with the mechanism. Mains power and control connections (IR sensor / receiver, contact closure) are all made at the control box. Telescopic To Mains Power Drive shaft Hinging bottom panel (removable for service & maintenance) Motor RS232 Link Control box wiring loom must Moving Panel Bracket Mechanism Cables be routed to the bottom right corner of the cabinet. Power Cables TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 8 FUTUREAUTOMATION
Page 9
SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL CONTROL BOX NOTE: RS232 CONTROL METHOD UNAVAILABLE. 8 1/8"207
HZ RS232 PORT IR OUTPUT INDICATOR LED CONTACT CLOSURE PORT EMERGENCY STOP IR LEAD INPUT max CONNECTOR 3.5mm [0.14"] JACK CABLE LOOM 20 LENGTH APPROX 13/16" 118 1/8" 8 CORE CABLE 3000 SPS SWITCHES 10mm [3/8"] dia. EU SPEC: 0.5mm² 1/4" US SPEC: 20AWG 7 5/16"8 4 CORE CABLE 2 CORE CABLE 52 SPS MOTOR 2 1/16" SPS MOTOR 10mm [0.4"] dia. MAINS INPUT 10mm [3/8"] dia. EU SPEC: 0.75mm² EU SPEC: 2.5mm² 5 US SPEC: 18AWG 5 7/8" 3/16" US SPEC: 14AWG 150 8 CORE CABLE ADVANCE BRACKET 10mm [3/8"] dia. NOTES EU SPEC: 0.5mm² US SPEC: 20AWG • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 9 FUTUREAUTOMATION
Page 10
SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL INSTALLATION OVERVIEW 2. Install the telescopic drive shaft between both sides of the mechanism. Ensure that the moving panel brackets are at the same height. Rear View Top Panel (removable for installation) Up Switch Adjustment Moving Panel Mechanism Loosen Bolt and slide the switch C Mount brackets (same on striker to desired position. Ensure both sides) bolt is tightened after adjustment. Hinging side panel Hinging side panel (removable for service & (removable for service Down Switch maintenance) & maintenance) Switch Striker Moving panel bracket Moving Panel Mechanism Motor 3. Run the mechanism, adjust the up Telescopic Drive shaft switch so that the carriages move the height of you panel + 25mm [1"]. Advance Bracket 1. Mount the Mechanism side channels to the side walls of the cabinet. Ensure the mechanism mount brackets are positioned 10mm back from the edge Up Switch of the front panels. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 10 FUTUREAUTOMATION
Page 11
SPS-HZ-6 - QA2-60 SLIDING PANEL MECHANISM - HORIZONTAL INSTALLATION OVERVIEW 4. Mount the moving panel to the moving panel brackets 200mm 5. Mount the moving panel back onto the mechanism, use the slots in the from the base of the moving panel and 94mm in from the edge. mount brackets to align the panel and get it into the desired position. Rear View of moving panel 3 11/16" 3 11/16" 94 94 3 11/16" 94 4 5/16"110 4 5/16"110
3 11/16" 94 7 7/8" 200 7 7/8" 200 Recommended to use 5mm shims to align the moving panel with the side of the aperture. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 11 FUTUREAUTOMATION