Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Future Automation OSL6684 technical sheet

Page 1 of 4100%
Text of this document4 pages · 789 words

Page 1

OSL 6684 OUTDOOR SPEAKER LIFT |MECHANISM AS SUPPLIED| |SPEAKER NOT INCLUDED| TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

OSL 6684 OUTDOOR SPEAKER LIFT B The mechanism Primary Frame will provide a watertight housing when in 18.31 SECTION C-C GENERAL DIMENSIONS the fully closed and fully open positions. 465 The maximum weight of the flap panel = 2kg [4.4lbs]. Floor pit can be back-filled with soil after installation if desired. The flap panel should be constructed from the same thickness material as the static, surrounding floor. 24.00 The flap panel can be cut to the same profile as the speaker if 609.6 desired - maximum square dimensions shown. 18.44 Flap Panel will drop and roll over 468.5 Floor Pit to the front of the mechanism The floor that immediately covers the mechanism should be Diameter before the speaker is raised. The AI AI easily removable to allow access for installation and speaker lifting beam will also maintenance. create a watertight seal against the underside of the mechanism A minimum 45mm [1.8"] soakaway area beneath the enclosure. mechanism should be allowed to ensure the mechanism is no submerged in any excess water that may accumulate in the floor pit. 1.97 max. 50 max. 7.28 max. 29.64 10.00 max. Flap/ Surrounding 185 max. 752.8 254 max. Floor Thickness Flap Flap Length B 23.62 Width C C 600 |PLAN VIEW| B Removable Floor Disc Flap Panel will create a watertight seal against 32.00 the underside of the 812.8 mechanism enclosure Speaker 52.76 when closed. 1340 Height Internal Height A A 1.77 45 Soakaway Area B SECTION B-B - CLOSED SECTION B-B - OPEN SECTION A-A TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

OSL 6684 OUTDOOR SPEAKER LIFT GROUND PREPARATION + FRAME INSTALLATION The modular design of this mechanism allows a flexible installation where space can be |STAGE 2| allocated in the ground during the early stages of construction using the Primary Frame. The speaker and flap panels can then be added at a later date. Position the Primary Frame so that the top face of the frame sits 5mm [0.2”] below the underside of the |STAGE 1| finished floor. The floor pit must be excavated to the minimum dimensions shown below. The NOTE: It is critical that the Primary Frame is Finished speaker will rise out of the center of the mechanism therefore the center of the positioned perfectly level and square as the lift Floor 0.2 min. speaker will be aligned with the center of floor pit. elements of the mechanism will be positioned Thickness 5 min. relative to the frame. Cables should enter the FRONT of the floor pit, 55mm [2.2”] below the underside of the finished floor. Once the position of the frame has been set, the floor pit can be back filled if desired - as a minimum A layer of gravel should be placed at the base of the pit to allow for water to requirement the frame should be packed out to the drain away. This layer should be minimum 45mm [1.8”] deep leaving 1295mm pit wall to aid stability when the speaker is revealed. [51”] of height between the gravel and the underside of the finished floor material. NOTE: If back filling with concrete, the concrete mix should be kept as dry as possible to minimize the 2.0 max. 50 max. chance of it flowing into the gravel layer and blocking Finished the soak-away. Floor 24.0 min. The concrete should only be filled up to the ‘FILL Thickness Cable Conduit 609.6 min. LINE’ marker on each side of the frame. D 2.2 55 E E 52.8 min. 51.0 1340 min. 1295 Internal Pit Depth Supplied Installation Brackets 19.9 1.8 (Cross beams not supplied) 505 45 Fill Line D Gravel Layer |SECTION D-D| TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

OSL 6684 OUTDOOR SPEAKER LIFT MECHANISM INSTALLATION |STAGE 4| |STAGE 3| To finish the installation of the mechansim the Flap Drive unit must be fixed to Once the Primary Frame position has been set the Lift Mechanism can be the top face of the Primary Frame. The speaker can be fixed into position above lowered onto hook pins located at the base. Securing bolts at the top of the Lift ground level so can be added at a later time if neccessary. Mechanism are then used to fix the unit to the Primary Frame. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 4 FUTUREAUTOMATION

Need assistance or looking to source this item?