Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Future Automation LSL1 technical sheet

Page 1 of 11100%
Text of this document11 pages · 1,148 words

Page 1

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP SPECIFICATION MEASUREMENTS Screen Sizes (Approx) 19" - 32" Maximum Weight Capacity 25Kg (55lb) Maximum Weight Capacity (Marine) 16Kg (35lb) Maximum Screen Height 410mm (16 1/8") Packaging Dimensions 920mm (36 1/4") x 550mm (21 5/8") x 250mm (9 13/16") Shipping Weight 15Kg (33lb) Movement Type Motorised Power Supply Required 110V or 240V AC Power Consumption 250-500W Power Consumption Standby 3W Decibel Rating 58dB Mounting Patterns Supported VESA 200 W x 300, 200 H Control Options IR Remote, RS232, Contact Closure Product Options / Features Specific B&O and Loewe mounts / adapters, Custom RAL paint finishes, Outdoor version Package Contents Mechanism, IR remote control, Push Flap Kit, Box Enclosure Kit Marine Suitable Yes (Indoor) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP CABLE ROUTING Screen cables are routed behind the Base Panel and out the right side of the Beam into the Cable Track. Cables must be routed carefully to prevent any interference with the LSL beam as it operates. Screen and Mechanism cables should be routed to a control box in the bottom of the cabinet. Cable track A 8 1/16" 204.5 To Mains 5 7/8" Power Cables can be secured to 149.5 the back of the cabinet and 2 1/16" routed to the control box 52 Cables exit Beam and DETAIL A enter Cable Track Beam TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP LSL-BE 1 - MECHANISM UP - IN CABINET 1/8" 3 Box enclosure to cabinet aperture Aperture Depth= Screen depth + 65mm [2 9/16"] (Minimum 85mm [3 3/8"]) 1/8" 13/16" 3 20 Base panel to Minimum distance from cabinet aperture SECTION C-C screen to inside of cabinet 1 3/4" B 44 C C Box enclosure width= Screen width + 40mm [1 9/16"] 16 1/8" 16 15/16" 410 3 1/8" 430 Maximum 80 Internal Box Screen Back of Mechanism enclosure height Height to Mount 13/16" 13/16" 20 20 D 22 13/16" 580 Internal cabinet height DETAIL D SECTION B-B B Minimum internal width = Screen Width +120mm [4 3/4"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 4 FUTUREAUTOMATION

Page 5

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP LSL-BE 1 - MECHANISM DOWN - IN CABINET 1/4" Shown with a tapered Box 6 Enclosure 14 9/16" Maximum 370 Lid in a square Cabinet Aperture. thickness of Minimum width of opening Box Enclosure in rear face of Box Enclosure A tapered Cabinet Aperture can be used to improve the fit G DETAIL G Aperture width = Screen width + 86mm [3 3/8"] 3 1/8" 80 E Back of Mechanism DETAIL F to Mount F 13/16" 20 Max Thickness of Base and Cabinet Top 16 15/16" 16 1/8" 430 410 Internal Maximum 22 13/16" Box Enclosure Screen 580 height Height Internal Cabinet height 6 5/16" 160 Minimum Screen height from base of Cabinet SECTION E-E E TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 5 FUTUREAUTOMATION

Page 6

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP LSL-BE 1 - BASE PANEL & LID DETAILS NOTE: A tapered Box Enclosure Lid creates a good fit in the Cabinet Aperture and helps the Box Enclosure to locate within the Cabinet. BOX ENCLOSURE LID (TAPERED) - TOP VIEW Lid Depth = Cabinet Aperture Depth - 2mm [1/16"] (Minimum 86mm [3 3/8"]) Box enclosure lid width = Cabinet Aperture - 2mm [1/16"] BASE PANEL - TOP VIEW 7 1/2" 190 1 1/2"38 Base Depth = Cabinet Aperture Depth - 6mm [1/4"] (Minimum 79mm [3 1/8"]) C L Cabinet Base width = Cabinet Aperture - 6mm [1/4"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 6 FUTUREAUTOMATION

Page 7

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP LSL-PF 1 - MECHANISM UP - IN CABINET Aperture Depth = Screen Depth +65mm [2 9/16"] (Minimum 85mm [3 3/8"]) 13/16" 20 Minimum distance from 1/8" 3 Screen to Edge of Base H 11/16" 17 3 1/4" 83 16 1/8" Back of Mechanism 410 to Mount 13/16" 13/16" Maximum 20 20 Screen Depth 13/16" I 20 22 13/16" 580 Internal DETAIL I Cabinet Height SECTION H-H H Minimum Internal Width = Screen Width +80mm [3 1/8"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 7 FUTUREAUTOMATION

Page 8

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP LSL-PF 1 - MECHANISM DOWN - IN CABINET Aperture Depth = Screen Depth +75mm [2 15/16"] Aperture Width = Screen Width + 46mm [1 13/16"] 3 1/8" 80 Back of Mechanism to Mount J 13/16" 20 Maximum Thickness of Cabinet Top and Base 16 1/8" 410 Maximum 22 13/16" Screen Depth 580 Internal Cabinet Height 5 7/8" 150 Maximum Screen Height from base of Cabinet SECTION J-J J TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 8 FUTUREAUTOMATION

Page 9

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP 3/8" 10 LSL-PF 1 - BASE PANEL & FLAP DETAILS 1/16" 2 FLAP PANEL - TOP VIEW DETAIL K Flap Panel Depth = Cabinet aperture Depth -6mm [1/4"] Flap Panel Width = Cabinet Width - 6mm [1/4"] K BASE PANEL - TOP VIEW 7 1/2" 190 1 1/2"38 Base Panel Depth= Cabinet Aperture Depth -29mm [1 1/8"] C L Base Panel Width = Cabinet Aperture Width - 6mm [1/4"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 9 FUTUREAUTOMATION

Page 10

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP MECHANISM INSTALLATION OVERVIEW Flap panel is attached to a hinge at the back of the cabinet aperture Box enclosure Lid Box enclosure Back Cover LSL is attached to the back of the cabinet with wood screws Box enclosure Top Box enclosure Support Back Section Box enclosure Base Push Flap Base LSL is attached to the back of the cabinet with wood screws TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 10 FUTUREAUTOMATION

Page 11

LSL-BE/PF 1 LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP OVERALL MECHANISM DIMENSIONS MECHANISM UP 7 7/8" 200 7 7/8" 200 MECHANISM DOWN 22 9/16" 573 22 13/16" 580 Back Plate Height

5 1/8"130 14 15/16" TECHNICAL SHEET 379 UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 003 WWW NET . . SHEET 11 FUTUREAUTOMATION

Need assistance or looking to source this item?