Rosette Electrical

Free worldwide shipping on selected Lutron hardwareFree shipping on selected Lutron

Need advice? Call +44 (0)207 031 5715Advice? +44 (0)207 031 5715

Future Automation LSH-S installation instructions

Page 1 of 42100%
Text of this document42 pages · 5,332 words

Page 1

LSH-S LIFT SYSTEM HEAVY SWIVEL INSTALLATION INSTRUCTIONS ISSUE 002

Page 3

SAFETY DISCLAIMER IMPORTANT SAFETY INSTRUCTIONS BELOW WARNING: Failure to provide adequate structural strengthening, prior to installation can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure the structure to which the component is affixed can support at least four times the combined weight of the component and any additional apparatus mounted to the component. WARNING: Do not exceed the weight capacity for this product as listed below. This can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure that the total combined weight of all attached components does not exceed that of the maximum figure stated. WARNING: Risk of death or serious injury may occur when children climb on audio and/or video equipment or furniture. A remote control or toys placed on the furnishing may encourage a child to climb on the furnishing and as a result the furnishing may tip over on to the child. WARNING: Risk of death or serious injury may occur. Relocating audio and/or video equipment to furniture not specifically designed to support audio and/or video equipment may result in death or serious injury due to the furnishing collapsing or overturning onto a child or adult. WARNING – RISK OF INJURY! Only for use with equipment weighing 100KG (220LBS) OR LESS. Use with heavier equipment may lead to instability causing tip over or failure resulting in death or serious injury. Bracket Suitable for Residential and Commercial Use. ADDITIONAL WARNINGS: 1. Keep all documentation/instructions after fitting. 2. Read all technical instructions fully before installation and use. It is the installer’s responsibility to ensure that all documentation is passed on to the end user and read fully before operation. 3. Do not use near water or outdoors unless the product has been specifically designed to do so. 4. Protect any cables or cords being used near this bracket from being walked on or pinched to prevent damage and risk of injury. 5. Use this product only for its intended purpose as described in the product instructions and only use attachments/ accessories specified by the manufacturer. 6. Do not operate the product if it is damaged in any way, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Contact the original installer/manufacturer to arrange repair or return. WARNING - To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Clean only with a dry cloth and always unplug any electrical items being used in conjunction with this product before cleaning. Future Sound & Vision trading as Future Automation intend to make this and all documentation as accurate as possible. However, Future Automation makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without prior notice or obligation of any kind. Future Automation makes no representation of warranty, expressed or implied, regarding the information contained herein. Future Automation assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document. 1

Page 4

PRODUCT WARRANTY & RISK ASSESSMENT WARRANTY INFORMATION WARNING - The warranty offered for this product shall be annulled if the product is used improperly or in a way that is in breach of our Terms of Service. Future Automation provides warranty for the mechanism you purchased for the period of 24 months from the date of purchase, provided that it isn’t used for unintended purposes. Under the warranty, Future Automation aims to either solve the issue remotely (via telephone or email support) or if the mechanism requires a part, arrange a visit to your premises by a Future Automation approved engineer or send replacement items where appropriate. Warranty repairs will be carried out as quickly as possible, but subject to parts availability. This warranty period is respectively extended for the period of a repair. A malfunctioning product must be cleaned and placed into suitable packaging to protect against transit damage before organising delivery to a repair workshop. All the complaints about defects must be submitted to the vendor/installer that sold this product, rather than directly to the manufacturer. Any part of your system that needs to be replaced during a warranty repair becomes the property of Future Automation. The warranty does not cover the following: • Damages resulting from improper product use or maintenance. • Repairs carried out by unauthorized persons. • Natural wear and tear during operation. • Damages caused by the buyer. • Accidental damages caused by a customer or damages caused as a result of careless attitude or usage, or damages caused by natural disasters (natural phenomena). • Any electrical, or other environmental work external to your Future Automation mechanism including power cuts, surges etc. • Additional items not supplied by Future Automation although they may have been supplied together by the retailer • Any 3rd party software products controlling your mechanism • Any transfer of ownership. Warranty is provided only to the initial purchaser. • Compensation for loss of use of the product, and consequential loss of any kind. A separate Safety and Servicing Information document is provided with these instructions (additional copies can be found at www.futureautomation.co.uk/safety), and this document MUST be filled out by the approved Future Automation Dealer who is installing the product. This Warranty Sheet must be held by the end user for the duration of the products life and will be referred to during servicing or warranty queries. The Safety and Servicing Information document also contains two Service History Forms that must be filled in by the approved Future Automation dealer who is performing the first required yearly service of this product. One copy of the Service History Form must be held by the customer (along with the Warranty Sheet) and a duplicate copy must be held by the approved Future Automation dealer that performed the service. Missing and/or mismatching documents may delay or invalidate warranty claims. Additional Service History Forms can be found on the Future Automation website for further yearly services. RISK ASSESSMENT INFORMATION It is the installer’s responsibility to perform a risk assessment of installed products. Future Automation can provide guidelines to installers/dealer about what should be included in a risk assessment, but due to the individual nuances of each location/site, Future Automation cannot provide a full list of areas to risk assess. For full risk assessment and safety information please view our Safety and Servicing guide available at www.futureautomation.net/safety 2

Page 5

GUIDE CONTENTS SAFETY DISCLAIMER 1 PRODUCT WARRANTY & RISK ASSESSMENT 2 GUIDE CONTENTS 3 PACKAGE CONTENTS 4 INITIAL TESTING 5 LSH-S FITTING 6 FP - TOP PANEL FITTING 12 BE - TOP PANEL FITTING 18 FP - TOP PANEL ADJUSTMENT 20 FP - BASE PANEL ADJUSTMENTS 22 BE - TOP PANEL ADJUSTMENTS 23 BE - BASE PANEL ADJUSTMENTS 26 FITTING THE SCREEN 27 LEVELING THE SCREEN 28 CABLE MANAGEMENT 29 GENERAL CONTROL 31 INFRARED (IR) 32 RADIO FREQUENCY (RF) 33 CONTACT CLOSURE 34 RS232 CONTROL 35 INTEGRATION CONSIDERATIONS 36 3

Page 6

PACKAGE CONTENTS 1 - LSH MECHANISM 1.1 - SCREEN MOUNT UPRIGHTS (X2) 2.4 1.2 - LIFTING BEAM 1.3 - BASE PANEL SUPPORT (X2) 1.4 - TOP PANEL MOUNT 2 - CONTROL BOX 2.1 2.1 - CONTROL BOX 2.3 2.2 - IR LEAD 2.3 - 3M LONG CABLE LOOM 2.4 - POWER SUPPLY UNIT 2.5 - CABLE CONNECTORS 2.5 3 - INFRARED (IR) REMOTE CONTROL 2.2 ITEMS NOT SHOWN ON PAGE TOOLS NEEDED LSH ACCESSORY PACK: - X2 AAA BATTERIES (Not Included) - MAINS POWER LEAD - INFRA-REF CONTROL LEAD SPIRIT LEVEL - CAT5 LEAD WITH RJ45 CONNECTOR - MULTI-PACK OF NUTS, BOLTS AND WASHERS - STOP KEY 1.4 3mm 5mm 6mm 3 1.1 1.1 1.3 1.2 4

Page 7

INITIAL TESTING Before installing the LSH mechanism: • Remove all red cable ties. • Check there is no damage to any part of the LSH mechanism, control board, or wiring. • Check all internal and external mechanism wiring is secure. WARNING: THE LSH MECHANISM DOES NOT HAVE AN ANTI-JAM CAPABILITY WHEN OPENING. THE MOTOR DRIVE SYSTEM WILL CONTINUE MOVING UNTIL IT REACHES A LIMIT SWITCH. KEEP HANDS AND ANY OBJECTS CLEAR OF THE MECHANISM DURING OPERATION TO REDUCE RISK OF DAMAGE OR INJURY. 1 Connect the control board to the LSH using the mechanism cable connectors at the end of the cable looms. Connect the IR lead into the control box and ensure that the emergency stop is secure. 2 Familiarise yourself with the mechanism. Pressing ‘OUT’ on the IR remote will raise the lifting beam. Pressing ‘IN’ will lower the lifting beam. Pressing ‘HOME’ will take the mechanism to an up position with no swivel rotation. 5

Page 8

LSH-S FITTING Place the LSH centrally within the aperture in the pit or cabinet. Ensure the 1 top of the mechanism is 10mm (3/8”) below the underside of the floor / cabinet top. Use blocks or a plinth to raise the mechanism if necessary. MECHANISM CENTRE LINE Once in the correct position, bolt the 2 mechanism to the back wall / panel. 6

Page 9

FP - BASE PANEL FITTING CONT. The base panel requires a cut-out detail 1 as shown below. CENTRE LINE 115mm [4 1/2”] R45mm [1 3/4”] 2 Remove the mount. Unscrew the M4 x12 screws in the cover plate. 2.5mm 3 Lift off the cover plate and set both the bolts and cover plate to one side until cables have been routed. 7

Page 10

FP - BASE PANEL FITTING CONT. Remove the 4 M5 x 20 bolts from the 4 bottom of the mount. 4mm Lift up the mount, taking care not to 5 damage the cabling. 6 Disconnect the Mini Connector before fully removing the mount and set to one side. 8

Page 11

FP - BASE PANEL FITTING CONT. 7 5mm [3/16"] Place base panel onto the base 5mm [3/16”] support bracket. 8 Ensure there is at least 5mm gap between the base panel and the aperture on all sides. Use 5mm shims to help align the base 9 panel within the aperture. 9

Page 12

FP - BASE PANEL FITTING CONT. Using the appropriate fixings, secure the base panel to the mechanism on both 10sides. Use the IR remote (page 15) to position the lifting beam for easier access. 11 Lift the mount back into position. 12 Reconnect Mini Connector before fully aligning mount. 10

Page 13

FP - BASE PANEL FITTING CONT. Reattach the 4 M5 x 20 bolts through the 13bottom of the mount. 13mm Add further bolts at the top and bottom of 14the mechanism as shown below. 15 On larger mechanisms (back tray >2130mm) there will also be a mid plate which should 11 be fixed at this stage.

Page 14

FP - TOP PANEL FITTING Lower mechanism till it hits the lower 1 limit switch. Top Panel Shelf mount bracket Place the Top Panel onto the shelf mount brackets. Fix the Top Panel from the 2 underside using the appropriate fixings. Top Panel dimensions can be found on the LSH tech sheet. 5mm [3/16"] 5mm [3/16”] Use 5mm shims to help align the top 3 panel within the aperture. CONTINUE TO PAGE 20 FOR CABLE MANAGEMENT 12

Page 15

BE - BASE PANEL FITTING CONT. The box enclosure requires specific cut- 1 outs, see tech sheet for details. 2 Remove the mount. Unscrew the cover plate. 3mm 3 Lift off the cover plate and set both the bolts and cover plate to one side until cables have been routed. 13

Page 16

BE - BASE PANEL FITTING CONT. Remove the 4no. M8 x 25 bolts from the 4 bottom of the mount. Save for later. 6mm Lift up the mount, taking care not to 5 damage the cabling. 6 Disconnect the Mini Connector before fully removing the mount and set to one side. 14

Page 17

BE - BASE PANEL FITTING CONT. 7 Rotate box enclosure frame around the mechanism. 5mm [3/16”] 8 Ensure there is at least a 5mm [3/16”] gap between the base panel and the aperture on all sides. Use 5mm [3/16”] shims to help align the 9 base panel within the aperture. 15

Page 18

BE - BASE PANEL FITTING CONT. Using the appropriate fixings, secure the base panel to the mechanism on both 10sides. Use the IR remote (page 15) to position the lifting beam for easier access. 11 Lift the mount into place and reconnect the Mini Connector. 16

Page 19

BE - BASE PANEL FITTING CONT. 12 6mm Reattach the mount using the 4no. M8 × 25 bolts. Do not fully tighten the bolts until after the next step. 13 Adjust the swivel so it is aligned straight with the aperture, then fully tighten the bolts. 17

Page 20

BE - TOP PANEL FITTING 15 AfÏx the top of the box enclosure to the uprights. 16 Add further bolts at the top and bottom of the mechanism as shown below. 17 On larger mechanisms (back tray >2130mm) there will also be a mid plate which should be fixed at this stage. 18

Page 21

BE - TOP PANEL FITTING The top panel uprights have safety switches built in, as well as the floating top. As such its critical that Lower the mechanism until it reaches the these adjustments are made correctly. 1 lower limit switch. Place the Top Panel onto the shelf mount brackets. Fix the Top Panel from the 2 underside using the appropriate fixings. Top Panel dimensions can be found on the LSH tech sheet. Top Panel Shelf mount bracket 19

Page 22

FP - TOP PANEL ADJUSTMENT Bring the mechanism out to its full extent. Check that the top and base panel move 4 through the aperture without snagging. Loosen the bolts on the back of the shelf mount brackets and raise the Top Panel 5 to 5mm above the screen. Re-tighten the bolts. 5mm 20

Page 23

FP - TOP PANEL ADJUSTMENT 5mm Loosen the bolts shown below to adjust the position of the bottom switch stop. Use the 1 serrated edge to make small adjustments to change its position. The bottom switch stop is factory set to its lowest position (This equals the top panel at its highest position for the largest possible screen size) As the screen size reduces ans the top panel gets lower the bottom switch will need to be 2 higher. Adjust the position of the bottom switch stop until the top panel is in line with the 3 top of the cabinet. 21

Page 24

FP - BASE PANEL ADJUSTMENTS Loosen the bolts shown below to adjust the position of the top switch stop. Only make small adjustments to the top 1 Use the serrated edge to make small switch to avoid any collisions. adjustments to change its position. The bottom switch stop is factory set to its lowest position. 5mm Adjust the position of the top switch stop until the base panel is in line with the top 2 of the cabinet. Base panel Make sure to tighten bolts after 3 adjustments. 22

Page 25

BE - TOP PANEL ADJUSTMENTS The top panel uprights have safety switches built in, as well as the floating top. As such its critical that Bring the mechanism out to its full extent. Check that these adjustments are made correctly. the top and base panel move through the aperture 1 without snagging. Loosen the bolts on the back of the shelf mount brackets and raise the Top Panel 2 to 5mm above the screen. Re-tighten the bolts. Shelf mount bracket fixings 5mm 23

Page 26

BE - TOP PANEL ADJUSTMENT 5mm Loosen the bolts shown below to adjust the position of the bottom switch stop. Use the 1 serrated edge to make small adjustments to change its position. The bottom switch stop is factory set to its lowest position (This equals the top panel at its highest position for the largest possible screen size) As the screen size reduces ans the top panel gets lower the bottom switch will need to be 2 higher. Adjust the position of the bottom switch stop until the top panel is in line with the 3 top of the cabinet. 24

Page 27

BE - TOP PANEL ADJUSTMENT Loosen or tighten the bolt under the floating panel to adjust the 6 level front to back. Adjust tightness if you have a heavy Top Panel. This will take 7 some of the weight and make the floating top safer with heavy weight Top Panels. KG 25

Page 28

BE - BASE PANEL ADJUSTMENTS Loosen the bolts shown below to adjust the position of Only make small adjustments to the top switch to avoid any collisions. the top switch stop. Use the serrated edge to make small 1 adjustments to change its position. The bottom switch stop is factory set to its lowest position. 5mm Adjust the position of the top switch stop until the base panel is in line with the top 2 of the cabinet. Base panel Make sure to tighten bolts after 3 adjustments. 26

Page 29

FITTING THE SCREEN Lay the screen face down on a padded surface and place the Screen Mount Uprights onto the screen’s four mount holes. Secure the Screen Mount Uprights to the back of the screen, using 1 the bolts and washers provided in the Fixings Pack as shown below. If the screen has recessed mount holes or if you need to space the uprights off for clearance, use the spacers provided in the Fixings Pack. NOTE: Screens that do not have standard VESA bolt patterns may require an adapter plate. Top of Screen X SIZE X Distance 5 15mm 6 115mm 7 15mm 8 115mm Lift the Screen and Screen Mount Uprights up and onto the Screen Mount Crossbars of the 2 LSH-S Bracket. 27

Page 30

LEVELING THE SCREEN The screen uprights have a grub screw that can be adjusted to allow the screen 1 to be levelled. Loosen all four pinch bolts and adjust 2 grub screws until the screen sits level. 5mm When the screen is level remember to re- 3 tighten all four pinch bolts. Lower Top Panel to 5mm from Top of Screen. Using ‘IN’ and ‘STOP’ on the IR 4 remote, carefully lower the mechanism to check the Top Panel aligns correctly with the cabinet aperture. 28

Page 31

CABLE MANAGEMENT Remove the mount cover plate and run 1 the cables down under the base panel. Run the cables under the base panel. This 2 can go both ways, left or right. 29

Page 32

CABLE MANAGEMENT IGUS Chain Next, guide the cables through the IGUS Chain and then to where required. 3 Reattach the mount cover plate. Ensure the cable loom is routed safely clear of the mechanism and does not obstruct or interfere with its movement. The control box must be stored in a safe, secure, and easily 4 accessible location. 30

Page 33

GENERAL CONTROL This mechanism has multiple standard control methods, each of which requires a different input method to the control box. For ease, the input sockets on the control board are labelled below. (Control box size and style may vary to image shown) CONTROL BOX INPUTS RS232 (RJ11/RJ25) Contact Closure (RJ45) Emergency Stop IR Input Jack (3.5mm) Input Confirmation LED MECHANISM EMERGENCY STOP CONNECTOR This mechanism features an Emergency Stop Connector, which MUST be plugged into the control box in the connector labelled above for the mechanism to operate. If this connector is not plugged in, the Input Confirmation LED will be permanently lit. As per the red plastic tag attached to the Emergency Stop Connector (and shown below), the small loop of wire in this connector is designed to be replaced by a third party safety mechanism. REPLACING MECHANISM BATTERIES The standard Future Automation Infrared (IR) remote control requires x2 AAA batteries to operate. These are provided with the mechanism in the Accessories Pack. These batteries can be replaced as per the image below. 31

Page 34

INFRARED (IR) This mechanism can be controlled via the supplied 14 button Infrared (IR) Remote Control, paired with the supplied Infrared (IR) lead and sensor. The mechanism's functions can be controlled by plugging the Infrared (IR) lead and sensor into the 3.5mm IR Input Jack shown on the General Mechanism Control page. Confirmation of Infrared (IR) input will be shown by a single flash of the large green LED located on the end of the control box. As Infrared (IR) control works via line of sight, the Infrared (IR) sensor must be directly viewable from the location the remote control is being used from. Infrared (IR) Remote Control Button Layout NOTE: Commands involving multiple keys requires each successive key to be pressed within 2 seconds of each other. IN - The mechanism is brought PRESET - Takes the screen to fully in. the rotation position saved to the ‘PRESET’ button. OUT - Raises the mechanism STORE, PRESET - Stores the fully out. No rotation. current rotation position to the ‘PRESET’ button. STOP - Stops the operation of STORE, A/B/C - Stores the the mechanism. current rotation position to buttons ‘A/B/C’. HOME - Takes the screen to a STORE, E - Clears right and left position with no rotation. swivel rotation limit and allows 180° rotation left and right. A-C - Takes the screen to the rotation position saved to STORE, F - Sets right rotation buttons ‘A-C’. limit. < OR > - Rotates screen left or STORE, D - Sets left rotation right. limit. Future Automation recommends that this mechanism operates with hold-to-run (Dead Man Switch) for user safety. This can be activated if required. https://fa.support/Files/PL-SAFETY-1 IMPORTANT Only buttons indicated above are functional with the product. Any other button press will STOP the mechanism. 32

Page 35

RADIO FREQUENCY (RF) If purchased with the Radio Frequency (RF) control option, this mechanism can be controlled via the supplied 4 button Radio Frequency (RF) Remote Control, paired with the in-built Radio Frequency (RF) sensor. Confirmation of Radio Frequency (RF) input will be shown by a single flash of the large green LED located on the end of the control box. Radio Frequency (RF) control does not require line of sight; however, signal performance can be affected by cabinet thickness, cabinet material or other electronic signals (i.e. strong Wi-Fi signals). Radio Frequency (RF) Remote Control Button Layout IN - Brings the mechanism into the cabinet. RIGHT - Rotates the mechanism towards the right. OUT - Brings the mechanism out LEFT - Rotates the mechanism of the cabinet. towards the left. The Radio Frequency (RF) Remote Control can only be used to recall the above functions. The mechanism limits and preset positions must be programmed using the supplied Infrared (IR) Remote Control. IMPORTANT Pressing any button while the mechanism is moving will STOP the mechanism. Future Automation recommends that the mechanism runs on a Dead Man (hold-to-run) system for user safety. The installer is responsible for carrying out the necessary risk assessments and end user training before proceeding without Dead Man functionality. 33

Page 36

CONTACT CLOSURE This mechanism can be controlled via Contact Closure, utilising the 8 Pin RJ45 Connector attached to a length of CAT5 (Type 568A or 568B) cable. The mechanism’s functions can be controlled by plugging this into the RJ45 port on the mechanism control board, then shorting pins 1-8 on this connector as shown in the Contact Closure Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box, as well as illumination of the corresponding Contact Closure LED on the printed circuit board as shown below. RJ45 Pin Layout Contact Closure LED Layout LED 1 LED 2 LED 3 LED 4 LED 5 (NOT USED) Contact Closure Input Port CONTACT CLOSURE INPUT TABLE PIN DESCRIPTION MOMENTARY ACTION WIRE/CABLE TYPE LED 568A 568B INDICATOR 1 12V SUPPLY 12V SUPPLY - CURRENT LIMITED 12V SUPPLY - CURRENT LIMITED W G W O 2 12V LATCH G O 3 GROUND GROUND GROUND W O W G MOTION TO PRESET D REQUIRES CONTINUOUS SHORT TO 4 PRESET D SHORT TO GROUND (PIN 3), MAKES DEVICE GO TO PRESET D. GROUND (PIN 3); RELEASING THE SHORT STOPS MOVEMENT B B IMMEDIATELY. MOMENTARY SHORT TO GROUND (PIN 3), WILL MAKE DEVICE MOTION LEFT REQUIRES CONTINUOUS SHORT TO GROUND W W 5 DEVICE LEFT GO LEFT OR STOP IF MOVING. (PIN 3); RELEASING THE SHORT STOPS MOVEMENT B B LED 4 IMMEDIATELY. MOMENTARY SHORT TO GROUND (PIN 3), WILL MAKE DEVICE MOTION RIGHT REQUIRES CONTINUOUS SHORT TO 6 DEVICE RIGHT GO RIGHT OR STOP IF MOVING. GROUND (PIN 3); RELEASING THE SHORT STOPS MOVEMENT O G LED 3 IMMEDIATELY. DEVICE HOME/ MOTION OUT REQUIRES CONTINUOUS SHORT TO GROUND W W 7 MOMENTARY SHORT TO GROUND (PIN 3), WILL MAKE DEVICE (PIN 3); RELEASING THE SHORT STOPS MOVEMENT BR LED 2 STOP GO HOME OR STOP IF MOVING. IMMEDIATELY. BR MOMENTARY SHORT TO GROUND (PIN 3), WILL MAKE DEVICE MOTION IN REQUIRES CONTINUOUS SHORT TO GROUND 8 DEVICE IN / STOP GO IN OR STOP IF MOVING. (PIN 3); RELEASING THE SHORT STOPS MOVEMENT BR BR LED 1 IMMEDIATELY. Future Automation recommends that the mechanism runs on a Dead Man (hold-to-run) system for user safety. The installer is responsible for carrying out the necessary risk assessments and end user training before proceeding without Dead Man functionality. 34

Page 37

RS232 CONTROL This Mechanism can be controlled via RS232, utilising a 6 Pin RJ11/RJ25 connector OR 9 Pin Serial connector attached to a length of 6 core cable. The mechanism's functions can be controlled by plugging this into the RJ11/RJ25 port on the mechanism control box, then inputting the RS232 commands shown in the RS232 Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box. RJ11/RJ25 PIN LAYOUT SERIAL PIN LAYOUT PIN 1: TX PIN 2: RX PIN 6: RX PIN 3: TX PIN 3 & 4: GROUND PIN 5: GROUND RS232 PROGRAMMING DETAILS RJ11/RJ25RJ11/RJ25 Func.Func. 9 PIN Serial9 PIN Serial ColourColour Baud Rate: 9600 PIN 1PIN 1 TX-RXTX-RX PIN 2PIN 2 Blue Stop Bit: 1 PIN 3PIN 3 GROUNDGROUND PIN 5PIN 5 Green Parity: None PIN 4PIN 4 GROUNDGROUND PIN 5PIN 5 Red Databits: 8 PIN 6PIN 6 RX-TXRX-TX PIN 3PIN 3 WhiteWhite RS232 INPUT TABLE IMPORTANT - Ensure all protocols are entered exactly as written below, including Carriage Return (ENTER / ASCII 13) Protocol Action fa_in Carriage Return (Enter / ASCII 13) Device IN fa_out Carriage Return (Enter / ASCII 13) Device OUT no movement to swivel fa_stop Carriage Return (Enter / ASCII 13) Device STOP (At any position) fa_home Carriage Return (Enter / ASCII 13) Device UP and swivel parallel fa_left Carriage Return (Enter / ASCII 13) Device UP and rotation to LEFT limit fa_right Carriage Return (Enter / ASCII 13) Device UP and rotation to RIGHT limit fa_a Carriage Return (Enter / ASCII 13) Device OUT and preset position A fa_b Carriage Return (Enter / ASCII 13) Device OUT and preset position B fa_c Carriage Return (Enter / ASCII 13) Device OUT and preset position C fa_preset Carriage Return (Enter / ASCII 13) Device UP and preset position “PRESET” Future Automation recommends that the mechanism runs on a Dead Man (hold-to-run) system for user safety. The installer is responsible for carrying out the necessary risk assessments and end user training before proceeding without Dead Man functionality. 35

Page 38

Cabinet Tape Switch Falling Cables could be follow link or scan the follow link or scan the

For more information on integrationQR below https://fa.support/Files/CabinetGuidanceFor more information on integrationQR below https://fa.support/Files/TapeSwitchLow Risk - Falling Objects Hazardobject hazard if objects are left on top of the top panel.Mitigation See general mitigations. Low Risk - Impact HazardImpact hazard around the mechanism when swivelling.Mitigation Set swivel limits to prevent impact with surrounding objects. See also general mitigations.Ensure sufÏcient cable slack is Low Risk - Crushing Hazardsnagged if not properly managed through and around the mechanism, causing damage to the mechanism and electronics. Mitigation allowed around movement joints to prevent stretching and/or damage to the cables and/or mechanism. allation, nstallation, Future Base Panel GENERAL MITIGATIONS:- Implement hold and run (Dead Man switch operation).- Control methods should be located within direct line of sight of the mechanism.- Implement password or key switch protected operation.Cabinet Top dance with applicable legislation and best practice. Top Panel specific risk assessment. Due to the unique conditions of each iwww.futureautomation.net/safety - Further safety and servicing guidance is available at: operation, and maintenance are identified and mitigated in accor High Risk - Crushing HazardCrush hazard between the top panel and the cabinet top when the mechanism is closing.Mitigation The top panel is constructed to allow vertical movement in the presence of an obstruction, causing the mechanism to return to open again.High Risk - Crushing HazardCrush hazard at the cabinet aperture when mechanism is opening.Mitigation A Tape Switch can be installed underneath the cabinet top to detect any obstructions. Scan the QR code and navigate to the Cabinet Guidelines document for further details.High Risk - Crushing HazardCrush hazard below the mechanism when the mechanism is closing.Mitigation Ensure the area below the mechanism is kept clear at all times when the mechanism is being used. If installing or maintaining the mechanism do so with the mechanism turned off.The installer is responsible for conducting a siteAutomation cannot provide an exhaustive list of all potential risks. Installers must ensure that all risks associated with inst LSH-S-FPLIFT SYSTEM HEAVY SWIVELINTEGRATION CONSIDERATIONS 36

Page 39

Cabinet Tape Switch Falling Cables could be follow link or scan the follow link or scan the

For more information on integrationQR below https://fa.support/Files/CabinetGuidanceFor more information on integrationQR below https://fa.support/Files/TapeSwitchLow Risk - Falling Objects Hazardobject hazard if objects are left on top of the top panel.Mitigation See general mitigations. Low Risk - Impact HazardImpact hazard around the mechanism when swivelling.Mitigation Set swivel limits to prevent impact with surrounding objects. See also general mitigations.Ensure sufÏcient cable slack is Low Risk - Crushing Hazardsnagged if not properly managed through and around the mechanism, causing damage to the mechanism and electronics. Mitigation allowed around movement joints to prevent stretching and/or damage to the cables and/or mechanism. allation, nstallation, Future Box Enclosure Cabinet Top GENERAL MITIGATIONS:- Implement hold and run (Dead Man switch operation).- Control methods should be located within direct line of sight of the mechanism.- Implement password or key switch protected operation. dance with applicable legislation and best practice. Top Panel specific risk assessment. Due to the unique conditions of each iwww.futureautomation.net/safety - Further safety and servicing guidance is available at: operation, and maintenance are identified and mitigated in accor High Risk - Crushing HazardCrush hazard between the top panel and the cabinet top when the mechanism is closing.Mitigation The top panel is constructed to allow vertical movement in the presence of an obstruction, causing the mechanism to return to open again.High Risk - Crushing HazardCrush hazard at the cabinet aperture when mechanism is opening.Mitigation A Tape Switch can be installed underneath the cabinet top to detect any obstructions. Scan the QR code and navigate to the Cabinet Guidelines document for further details.High Risk - Crushing HazardCrush hazard below the mechanism when the mechanism is closing.Mitigation Ensure the area below the mechanism is kept clear at all times when the mechanism is being used. If installing or maintaining the mechanism do so with the mechanism turned off.The installer is responsible for conducting a siteAutomation cannot provide an exhaustive list of all potential risks. Installers must ensure that all risks associated with inst LSH-S-BE LIFT SYSTEM HEAVY SWIVELINTEGRATION CONSIDERATIONS 37

Page 40

NOTES

Page 42

EUROPEAN OFFICE NORTH AMERICAN OFFICE Address: Address: Unit 6-8 Enterprise Park Brunel Road 127 Venture Drive Bedford Dover Bedfordshire NH MK41 9TG 03820 Phone: +44 (0) 1438 833577 Phone: +1 (603) 742 9181 Email: info@futureautomation.co.uk Email: info@futureautomation.net OfÏce Hours: OfÏce Hours: Mon - Fri 8:00 to 17:30 GMT Mon - Fri 7:00 to 17:00 EST Saturday & Sunday - Closed Saturday & Sunday - Closed www.FUTUREAUTOMATION.net

Need assistance or looking to source this item?