Application Notes HSE Contents Page
Installation 2 Referencing 3 Referencing when installing a new chip 3 Referencing after adjusting or replacing a potentiometer 3 Adjusting the docking speed (only available for mechanisms supplied after 02 / 2017) 4 Factory Reset 4 Controlling the Mechanism 5
Page 1 of 5 // email info@futureautomation.co.uk US tel +1(603) 742 9181 Europe tel +44 (0) 1438 833577
Page 2
Installation 1) The HSE allows for up to 7 user programmable presets positions, assigned to the A, B, C, D, E, F and PRESET commands. These are defaulted at 7 evenly spaced intervals throughout the 90 degree arc of the mechanism. 2) Use the Future Automation IR remote to set each programmable position 3) Move the mechanism to the required position using [IN], [OUT] and [STOP] 4) Press [STORE] followed no more than 2 seconds later by the key associated with your chosen preset.
Page 2 of 5 // email info@futureautomation.co.uk US tel +1(603) 742 9181 Europe tel +44 (0) 1438 833577
Page 3
Referencing
A newly supplied mechanism will not need referencing as this has already been done prior to dispatch. Referencing is a process which must be performed whenever the mechanism needs to “learn” the limits of its own travel. Some service/maintenance procedures may require the unit to be re-referenced.
Referencing when installing a new chip 1) Press [IN] until the mechanism stops at its fully closed position 2) Press [OUT] until the mechanism stops at its full 90 degrees switch 3) The mechanism is now referenced
Referencing after adjusting or replacing a potentiometer 1) Press [STORE] [STORE] [HOME] to perform a factory reset (note: this will remove any previously stored viewing angles) 2) Press [IN] until the mechanism stops at its fully closed position 3) Press [OUT] until the mechanism stops at its full 90 degrees switch 4) The mechanism is now referenced 5) Reprogram the required viewing angles (follow the instructions in the Installation Section above)
Page 3 of 5 // email info@futureautomation.co.uk US tel +1(603) 742 9181 Europe tel +44 (0) 1438 833577
Page 4
Adjusting the docking speed (only available for mechanisms supplied after 02 / 2017)
Do not alter docking speed unless specifically advised by Future Automation. The default docking speed is suitable for the entire weight range of this mechanism and should not need to be adjusted. It is set at a value which optimally dampens any shaking caused by loss of momentum as the mechanism stops. However, in exceptional circumstances docking can be adjusted as follows a) [STORE] [STORE] [>] - fractionally increases the docking speed b) [STORE] [STORE] [<] - fractionally decreases the docking speed c) Successive adjustments can be used in this way to tailor docking speed to specific requirements.
Factory Reset Completely restores the mechanism to all default settings. NOTE: the mechanism must be fully referenced again after a factory reset. Any viewing angles or customized docking speeds will need to be reprogrammed.
Page 4 of 5 // email info@futureautomation.co.uk US tel +1(603) 742 9181 Europe tel +44 (0) 1438 833577
Page 5
Controlling the Mechanism RS232 commands are all terminated with carriage return but no line feed. In Crestron this is represented by r IR sequences involving multiple key-presses require each successive key to be pressed within 2 seconds
IR RS232 CC Pin Action Comments Sequence IN fa_in Pin 8 Or Pin 5 System fully in short removed OUT fa_out Pin 7 System fully out STORE Store current Inactive when not referenced A position as Preset A STORE Store current Inactive when not referenced B position as Preset B STORE Store current Inactive when not referenced C position as Preset C STORE Store current Inactive when not referenced D position as Preset D STORE Store current Inactive when not referenced E position as Preset E STORE Store current Inactive when not referenced F position as Preset F STORE Store current Inactive when not referenced PRESET position as Preset PRESET A fa_a Move to Preset A Inactive when not referenced B fa_b Move to Preset B Inactive when not referenced C fa_c Move to Preset C Inactive when not referenced D fa_d Pin 5 shorted Move to Preset D Inactive when not referenced E fa_e Move to Preset E Inactive when not referenced F fa_f Move to Preset F Inactive when not referenced PRESET fa_preset Move to Preset Inactive when not referenced PRESET STOP fa_stop Pin 6 Stop Mechanism Inactive when not referenced STORE Factory reset Mechanism must be referenced and STORE the viewing angles re programmed HOME after a factory reset