This document could not be shown here. Open the PDF.
Text of this document9 pages · 701 words
Page 1
CME CEILING MOUNT ELECTRIC TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 005 . . WWW NET SHEET 1 FUTUREAUTOMATION
Page 2
CME CEILING MOUNT ELECTRIC SPECIFICATION MEASUREMENTS Pole Outer Diameter 51mm (2") Pole Inner Diameter 48mm (1.88") Maximum Weight Capacity 50Kg (110lb) Decibel Rating 44Db 71mm (2.8") Pole Centre to Rear of Screen Product Weight Variable Packaging Dimensions Variable Shipping Weight Variable - Bi-directional Maximum Rotation 180 Maximum Tilt 30 Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption Standby 3W Cable Management Through pole centre Mounting Patterns Supported VESA 400, 300, 200 W x 400, 300, 200 H Control Options IR Remote, RS232, Contact Closure Product Options / Features Specific B&O and Loewe mounts / adapters, Custom RAL paint finishes, Marine suitable version Package Contents Mechanism, IR remote control Marine Suitable No TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 005 . . WWW NET SHEET 2 FUTUREAUTOMATION
Page 3
CME CEILING MOUNT ELECTRIC MECHANISM MOUNTING OPTIONS The mechanism is supplied with all necessary components for mounting UNISTRUT MOUNTING between joists, on a flat platform between joists, or to suspend from a Unistrut arrangement above. Telescopic Joist Mounting Brackets are attached as standard and must be removed for platform or unistrut mounting. MOUNTING BETWEEN JOISTS Telescopic Joist Mounting Brackets Slots in the top faces allow for M8 studding to be fixed between unistrut and mechanism PLATFORM MOUNTING All Mounting Brackets removed to allow for fixing directly through Base Panel TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 005 . . WWW NET SHEET 3 FUTUREAUTOMATION
Page 4
CME CEILING MOUNT ELECTRIC Cable Management The CME's mounting allows for cables from the screen to be fed through the intergrated cable management. This allows Screen Cables the cables to be stowed tidily and safely within the mechanism. Enter Pole Here The Mechanism Cable should be routed to the provided control 5.9 box. This should be stored in an easily accessible location. 2.0 150 52 Screen Cables 5.4 138 Mechanism Cables Power Cable To Mains Power AC Screen Cable Exit Pole Here TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 005 . . WWW NET SHEET 4 FUTUREAUTOMATION
Page 5
CME CEILING MOUNT ELECTRIC 355 [14.0] max MOUNTING BETWEEN JOISTS 235 [9.3] min 2.0 min. 514 [20.2] max 50 min. 360 [14.2] min Cable Cleanrance 15.7 Ceiling Joists
400 SECTION B-B C 5.0 Ceiling
127 A B B 1.1
29 0.4
10 A 3.1 80 Clearance Hole DETAIL C SECTION A-A TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 005 . . WWW NET SHEET 5 FUTUREAUTOMATION
Page 6
CME CEILING MOUNT ELECTRIC D 5.9 9.8 PLATFORM MOUTING
150 250 2.0 min. 50 min. Cable Clearance 3.9 100 Ceiling Joists
Ceiling Load Beaing Platform 3.7 max. E
95 max. D 0.4
10 3.1 80 1.1 max. Clearance
29 max. Hole DETAIL E SECTION D-D TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 005 . . WWW NET SHEET 6 FUTUREAUTOMATION
Page 7
CME CEILING MOUNT ELECTRIC 12.2
310 UNISTRUT MOUNTING 7.5 Slots for M8 Studding
190 Unistrut (Not Supplied) M8 Studding 2.0 min. (Not Supplied) 50 min. Cable Clearance 7.2 183
1.8 5.7 3.7 max. G Ceiling
45 145
95 max. F 1.1 max.
29 max. 7.9 200
10 80 Clearance Hole SECTION F-F F DETAIL G TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 005 . . WWW NET SHEET 7 FUTUREAUTOMATION
Page 8
CME CEILING MOUNT ELECTRIC MECHANISM DIMENSIONS 7.9 200
15.7
400 514 [20.2] max 2.5 5.9 9.8
64 360 [14.2] min
150 250 1.1
29 3.8 0.2
98
4 Distance from Ceiling to Centre 19.3 490 18.1 460 of Screen
17.1
435 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 005 . . WWW NET SHEET 8 FUTUREAUTOMATION
Page 9
CME CEILING MOUNT ELECTRIC TILT DETAILS 30° MAX TILT 2 x Handles used to lock / unlock ceiling mount tilt. H H DETAIL H TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 005 . . WWW NET SHEET 9 FUTUREAUTOMATION DETAIL H SCALE 2 : 5
Need assistance or looking to source this item?