This document could not be shown here. Open the PDF.
Text of this document2 pages · 1,780 words
Page 1
Turn OFF power at circuit breaker or remove fuse Removing the Construction Cover 1 5 WARNING: SHOCK HAZARD. If the keypad already has a button kit installed (RR-HD), Dimmer 044424 Rev A May result in serious injury or death. Always isolate the mains power skip to step 8. 03/2025 supply or remove fuse before servicing or installing. Please read before installing. English If the keypad does not have a button kit installed (RRE-HDS-1), follow the instructions below to install the RRE-HDS-1 button kit (button kit is sold separately). RR-HD 220 - 240 V~ 50 / 60 Hz Use a screwdriver or other tool to pry free the corners of 1 A 150 W 250 W the construction cover and remove the construction cover LED LED Inc. / Hal. / ELV DEL from the keypad. Included Components L oad types and ratings 2 Bulk Hybrid Keypad 1 Adding the Button Kit Mounting Plate Minimum Load Neutral Connection 6 2 Button Kit Load Type Maximum Load Construction Cover With Neutral Without Neutral Dimming Switching Snap the construction cover onto the button kit. Mounting Screws 1 LED 0 W 10 W 1 A 150 W Preferred 1 When Included ELV with LEDs 10 W - 250 W Required 2 For RR-HD only ELV with Inc./Hal. 10 W - 250 W Required Inc./Hal. 0 W 10 W 250 W Preferred Required Help PHPM-PA-CE 1 interface - 3 interfaces Required GRX-TVI 1 interface - 3 interfaces Required RA3 Support Center 1 LED rating is 1 A. If no current rating is specified on the LED lamp, a power rating of 150 W can be used. For additional support with NOTE: Do not install hybrid keypads to control sockets or motor-operated appliances. installing, programming, and troubleshooting W iring 3 With Neutral Wiring (Dimming or Switching Mode) Without Neutral Wiring (Dimming Mode Only) Connect the wires using one N = Neutral N = Neutral lutron.com/RA3support of the two diagrams. L = Live L = Live = Earth = Earth A dding the Construction Cover to the Keypad 7 Europe: +44.(0)20.7702.0657 Breaker = Controlled Output Load Breaker = Dimmed Live Load Indonesia: 001.803.011.3994 Snap the construction cover onto the keypad, engaging KSA: 140.025.05512 0,6 N•m 0,6 N•m the top two snaps first and then the bottom two. Singapore: 800.120.4491 Replace the construction cover with the wallplate after Thailand: 001.800.120.665853 construction has been completed. UAE: +800.031.10102 L L Note: Wallplate installation instructions are included India: 000800.050.1992 N N N N with the wallplate. U.S.A. / Canada: 1.844.LUTRON1 Mexico: +1.888.235.2910 Other Countries (toll): +971600521581 Products must be installed in accordance with www.lutron.com/support 5 mm the latest building and wiring regulations. Note: Terminals are designed for one wire per terminal only. Turn ON power at circuit breaker or install fuse Limited Warranty: 8 https://assets.lutron.com/a/documents/intl_warranty.pdf Mounting 4 Depth: 35 mm minimum Hereby, Lutron Electronics Co., Inc. declares that the radio equipment type RRE-HDS-1 and RR-HD are in compliance with Directive 2014/53/EU The full text of the EU declaration of conformity is available at the following internet address: lutron.com/cedoc Lutron, RadioRA 3, and any related trade dress and logos are M3.5 mm x trademarks or registered trademarks of Lutron Electronics Co., Inc. in 30 mm the US and/or other countries. System setup All other product names, logos, and brands are property of their 9 respective owners. Wallplate installation instructions are included with the wallplate. For control of other dimmers, switches, and shades this hybrid keypad must be used in a RadioRA 3 system with a processor. Mount the hybrid keypad to the backbox using the horizontally Use the RadioRA 3 programming software to setup the system (training is required to access the software). located screw holes only as shown. Replace construction cover with wallplate after construction has Do not attempt to program a keypad if the keypad does not have a button kit installed. ©2025 Lutron Electronics Co., Inc. been completed.
Page 2
Default button operation shown. They will be IMPORTANT over-written by the system software during system programming. 1. CAUTION: Use only with permanently installed lighting fixtures. To avoid overheating and possible damage to other equipment, do not use to control sockets. 2. Install in accordance with all national and local electrical codes. LED A 3. For indoor use only between 0 °C and 40 °C (32 °F and 104 °F); 0% – 90% humidity, non-condensing. ON Return to Factory Settings Note: Returning a hybrid keypad to its factory settings will remove the hybrid keypad from the system and erase all programming. Step 1: Triple tap the top button on the hybrid keypad. DO NOT release after third tap. Step 2: Keep the button pressed on the third tap until all the status LEDs start to flash slowly (approximately 3 seconds). Step 3: Immediately release the button and triple tap the button again. The status LEDs on the hybrid keypad will flash quickly. LED C OFF The hybrid keypad has now been returned to its factory settings. 3 sec 2-Button Troubleshooting LED A ON Symptoms Probable cause Action LED A blinks 1 second ON, 1 second OFF Live and dimmed live/controlled output wires are reversed Check wiring against Step 3 of the instructions. LEDs A and C alternate blinking 1 second ON, Over-voltage detected 1. Ensure the input voltage to the device is less than 260 V~. LED B 50% 1 second OFF 2. Verify the device is not controlling a magnetic low-voltage transformer. LED A is constantly ON. 1. Check the wiring against Step 3 of the instructions. Verify that the neutral and dimmed live wires are not swapped. LED C blinks 1 second ON, 1 second OFF Over-current detected 2. Check for short circuits to neutral or ground in all wiring locations, including at the load. LED C OFF 3. Replace the load(s) to check if it failed as a short. LEDs A and C blink together 1 second ON, Over-temperature detected 1. Ensure load is within ratings noted in the instructions. 1 second OFF 2. Ensure ambient temperature is less than 40 °C. 1 Low-end trim may need to be adjusted for best LED lamp performance. If the device is activated into the system, trim can be adjusted in the The low-end is not adjusted Lutron app. If not, trim must be adjusted locally by following the instructions contained in Application Note #851 (P/N 048851). LED lamps do not operate well or they flicker / buzz The lamp is not compatible with your Lutron dimmer Verify LED lamps are marked dimmable. Replace the lamp(s). The lamp is not compatible without use of neutral wiring Add neutral to the hybrid keypad. See Step 3 of the instructions. 1 Low-end trim may need to be adjusted for best LED lamp performance. If the device is activated into the system, trim can be adjusted in the 3-Button with LED lamps do not dim low enough The low-end is not adjusted Lutron app. If not, trim must be adjusted locally by following the instructions contained in Application Note #851 (P/N 048851). 1 High-end trim may need to be adjusted for best LED lamp performance. If the device is activated into the system, trim can be adjusted in the Raise / Lower The high-end needs adjustment Lutron app. If not, trim must be adjusted locally by following the instructions contained in Application Note #851 (P/N 048851). LED lamps flicker repeatedly at high-end The lamp is not compatible with your Lutron dimmer Verify LED lamps are marked dimmable. Replace the lamp(s). The lamp is not compatible without use of neutral wiring Add neutral to the hybrid keypad. See Step 3 of the instructions. The dimmer, switch or shade / drapery is not assigned to the hybrid Refer to the programming software and ensure the device is assigned to the hybrid keypad. Perform a transfer and make sure it is successful. keypad A specific dimmer, switch or shade / drapery is not Failure has occurred on the lamp(s) controlled by the dimmer / switch Replace the lamp(s). LED A ON controlled when a button is pressed on the hybrid There is no power to the dimmer, switch, shade / drapery 1. Circuit breaker OFF or fuse is faulty. Turn ON breaker or replace fuse. keypad 2. Verify that the wire connections did not come loose. Devices are out of range or is positioned too close to a non-Lutron Ensure this device is placed within 6 m of two additional compatible wireless devices and greater than 2 m away from wireless interference 2.4 GHz device or other potential interference source sources like microwaves, Wireless Access Points (WAPs), etc. LED B 50% Dimmer, switch or shade / drapery does not go to The button was not programmed correctly Refer to the programming software and ensure the device is assigned to the hybrid keypad. Perform a transfer and make sure it is successful. the desired level or position when a button on the Devices are out of range or is positioned too close to a non-Lutron Ensure this device is placed within 6 m of two additional compatible wireless devices and greater than 2 m away from wireless interference hybrid keypad is pressed 2.4 GHz device or other potential interference source sources like microwaves, Wireless Access Points (WAPs), etc. LED C OFF All status LEDs on the hybrid keypad flash when any The hybrid keypad is in the Factory Settings mode and has not been Refer to the programming software and ensure the device is assigned to that hybrid keypad. Perform a transfer and make sure it is successful. button is pressed configured to work in a system Power not present at hybrid keypad 1. Circuit breaker OFF or fuse is faulty. Turn ON breaker or replace fuse. Lights do not respond to a hybrid keypad button 2. Verify that the wire connections did not come loose. LED D OFF press or do not go to desired levels Lamps burned out or not installed Replace or install lamps. Non-dimmable lamps If non-dimmable lamps are being used, replace with dimmable lamps. Improper programming Program according to the system Setup Guide. 4-Button Attached lights turn ON when top hybrid keypad Load is less than minimum load requirement Make sure the connected load meets the appropriate minimum load requirement for the control. See Step 2, Load types and derating. button is pressed, then turn OFF Improper programming Program according to the system Setup Guide. Wallplate is warm Solid-state control dissipation Solid-state hybrid keypads internally dissipate about 2% of the total connected load. It is normal for hybrid keypads to feel warm to the touch during operation. 1 The local high-end and low-end trim menus are only accessible if the device is in dimming mode.
Need assistance or looking to source this item?