QS Wallbox Closure Interface QSE-CI-WCI Control Interface 369681b 1 08.26.15 QS Wallbox Closure Interface The QSE-CI-WCI (WCI) is a control interface for use with HomeWorks® QS systems, Quantum® systems, and QS standalone applications. The WCI integrates a contact closure keypad with a Lutron® lighting control system. The contact closure keypad must be provided by the customer. The WCI provides up to eight contact closure inputs (CCIs). The CCIs accept maintained or momentary signals. The CCIs are programmable through the HomeWorks® QS and Shown actual size. Quantum® system setup software. For QS standalone applications, the CCIs are programmable using the button, DIP switch, and LEDs on the WCI. Features • Provides 8 contact closure inputs (CCIs), maintained - Verification of which contacts are closed. or momentary. - Indication of communication miswire/malfunction. • Works with SELV / PELV / NEC® Class 2, low-voltage, • Programming button allows for ease of programming dry contact closures. and resetting to factory default. • The CCI can be set up to simulate existing Lutron® keypad functionality or custom-configured to meet Functionality in QS Standalone Systems project-specific requirements. • GRAFIK Eye® QS (QSGRx-) • Place in the wallbox behind a contact closure keypad - Inputs activate Scenes. (See Mounting). - Toggle Zones between a Preset and Off. • Provides a 1-way interface between the Lutron® - Cannot be used as a partion controller. lighting system and a contact closure keypad (not • Energi Savr NodeTM (QSN- or QSNE-) supplied). - Inputs activate Scenes. • For use in HomeWorks® QS systems, Quantum® - Toggle Zones between a Preset and Off. systems, and QS standalone applications. - Cannot be used as a partion controller. • Motor Module (QSE-CI-4M) Additional Programming Details - Window treatment Open/Stop/Close. • In HomeWorks® QS and Quantum® systems, the - Toggle assigned windows treatments between 8 CCIs are individually programmable through the Open and Close. appropriate setup software. • Contact Closure Interface (QSE-IO) • For QS standalone applications, the DIP switch allows • Sivoia® QS for selection of CCI control options: - Window treatment Open/Preset/Close. - With or without raise/lower controls. - Supports venetian window treatments. - With all momentary or all maintained CCIs. - Supports 6 default presets (4 presets when applying • LEDs provide instant feedback during setup and Raise/Lower). diagnostics; - Confirmation when programming. 1 ® SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 2
QS Wallbox Closure Interface QSE-CI-WCI Control Interface 369681b 2 08.26.15 Specifications Regulatory Approvals Environment • CE marked • Ambient Operating Temperature: 0 °C to 40 °C • Complies with IEC standards 60669-2-1 and (32 °F to 104 °F) 50428:2005 • Relative Humidity less than 90%, non-condensing • If UL listing is required, please contact Lutron • For indoor use only Input Power Terminals 2 (18 AWG) • Operating Voltage: 24–36 V- 20 mA • Each terminal accepts up to two 1.0 mm 2 • Low Voltage SELV / PELV / NEC® Class 2 wiring provides wires, one twisted shielded pair 0.5 mm (22 AWG) 2 power, derived from QS link. Consumes one Power wire or one 4.0 mm (12 AWG) wire typical. Draw Unit (PDU). Mounting Contact Closure Input Types • Recommended to be placed in the wallbox behind a • The QSE-CI-WCI (WCI) is compatible with both contact closure keypad. momentary and maintained contact closure inputs • Lutron recommends using a wallbox which is 60 mm 1 1 (CCIs). (2 ⁄2 in) deep x 60 mm (2 ⁄2 in) wide, when installing • Contact closure keypad must have a low voltage, dry the WCI. Note: Some applications may require a contact closure rating. deeper wallbox. • CCIs must have an on-state saturation voltage less • If alternative mounting is required, do not extend wiring than 1 V at 1 mA and an off-state leakage current of harness more than 45 m (150 ft). less than 100 uA. Contact manufacturer of the contact closure keypad for details. QS Link Limits • The signal pulse for the CCI must be greater than • Please refer to the system spec for details regarding 40 ms. Contact manufacturer of the contact closure your application. keypad for details. • The WCI is not designed or rated to work with line/ mains voltage switches. Use with line/mains voltage switches will result in premature failure. 2 ® SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 3
QS Wallbox Closure Interface QSE-CI-WCI Control Interface 369681b 3 08.26.15 Mechanical Dimensions Front View Side View Back View ) 5 in ® m 7 8 ) . 60 m 1 5 in 7 3 m ( MUX MUX V+ COM . 2 ( 4 3 2 1 7 m 4 52 mm (2.0625 in) 21 mm (.8125 in) 3 ® SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 4
QS Wallbox Closure Interface QSE-CI-WCI Control Interface 369681b 4 08.26.15 Wiring QS Wiring
g irin ® W k in MUX MUX V+ COM L 4 3 2 1 S Q MUX (White) MUX (Purple) V+ (Red) COM (Black) Contact Closure Wiring Contact closure wire colors 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 • Connect the contact closures to the contact 1 2 3 4 5 6 7 8 COM 12 ® closure inputs (CCIs) and shared common QSE-CI-WCI LEDs een ey INPUTS ellow ENTRADA using supplied wiring harness. Red Orange Y Gr Blue Purple Gr White Black ENTRÉES COM 1 2 3 4 5 6 7 8 • Ensure proper function, and cap all unused CCI wires together, away from other CCI 1 (Red) COM circuitry. Contact 1 2 3 4 5 6 7 8 Closure Note: All contact closures must share the provided common. (Black) Contact CCI 8 (White) Closure Common (Black) Contact Closure Inputs Communication Note: Connect CCI wires link wiring appropriately 1 2 3 4 5 6 7 8 LEDs put in e Contact Closure Inputs r u s ) ) ) o e w e ) ) g o n) ) ) d n ll e e rpl y ck cl e u a a t e r l u r l Re Ora Y G B P c ( ( ( ( ( ( (G (B 1 2 3 4 5 6 7 8 9 a t n Wallbox o C Input Wiring Harness: Approximately 178 mm (7 in) long with 13 mm (1/2 in) pre-stripped end. 4 ® SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number: