Instruction Manual DIN-4C 4 Channel Curtain/Blind Controller

2026 Version 1.0.3

Page 2

Contents 1 What is the DIN-4C? 3 1.1 Product Image 3 1.2 Product Features 3 1.3 Load Types 3 1.4 Example DIN System 4 2 Panel Overview 4 3 DIN-LINK Modules 5 4 Installation Instructions 6 5 Servicing the DIN-4C 7 6 Programming the DIN-4C 8 7 LED Diagnostics 8 7.1 Display 8 7.2 Output LEDs 9 8 Installation Guidelines 9 8.1 Electrical Isolation 9 8.2 Mounting 9 8.3 Enclosure and Environmental Protection 9 8.4 Maximum and Minimum Loadings 9 8.5 Overcurrent Protection 10 8.6 Wiring 10 8.7 Ventilation and Cooling 10 8.8 Compatibility 10 8.9 Third-Party Accessories and Equipment 10 8.10 Sound Pressure Levels 10 Appendix 1 - Wiring Options 11

DIN-4C Instruction Manual | Page 2 Manual Version 1.0.3

Page 3

1 What is the DIN-4C?

1.1 Product Image

1.2 Product Features Four channels of dual-relay outputs for curtain/blind motors Momentary or latching action relays with automatic timeout Controlled via the Rako Wired Network using keypads such as the WK-MOD or WCM. Controlled by Rako Wireless Keypads, such as the RK-MOD and RNC, when used in conjunction with a WK-HUB or WRB100

1.3 Load Types Load Type Load Voltage Max Load

230VAC 1.5A/Channel

AC Motor 12V DC – 1.5A/Channel

24V DC DC Motor

Not Relevant Not Relevant

Dry Contact DIN-4C Instruction Manual | Page 3 Manual Version 1.0.3

Page 4

1.4 Example DIN System

2 Panel Overview

DIN-4C Instruction Manual | Page 4 Manual Version 1.0.3

Page 5

No. Description 1 The input terminals for the DIN bus. 2 Each relay output of the DIN-4C has two LED indicators and a test button. 3 The motors are connected to four twin relay outputs. 4 Box number for identification during programming and operation. 5 Seven-segment display for diagnostic feedback. 6 Locks the DIN-4C to the DIN rail when the clip is pushed up.

3 DIN-LINK Modules

The DIN-LINK is used to communicate with four types of modules: DIN-4T, DIN-8S, DIN-4C and DIN-DLI.

Each DIN-LINK module is connected via the DIN bus. The DIN-LINK has a maximum capacity calculated in DIN Power Units (DPU). The maximum DPU per DIN-LINK is 64.

Device Description Diagram DPU Four-channel trailing-edge dimmer module. It is suitable for DIN-4T 8 controlling mains dimmable loads.

Eight-channel relay DIN-8S module for on/off 8 switching.

A four-channel DIN-4C curtain and blind 8 controller module.

DIN-4C Instruction Manual | Page 5 Manual Version 1.0.3

Page 6

DIN-DLI Multi Room DALI 16 Controller

4 Installation Instructions

The overall safety of any system incorporating this equipment is the responsibility of the assembler of the end system. A qualified electrician must install the DIN module. Ensure all wiring follows local electrical standards. Use only appropriately rated cables, and secure all connections before powering on. The DIN module must be connected to a supply that includes appropriate protective devices. Failure to comply with these requirements may result in damage to the equipment, risk of fire, or electrical hazards.

Pull down the DIN 1 clamp at the bottom of the unit to unlock it.

Once unlocked, place 2 the DIN-4C over the DIN rail.

DIN-4C Instruction Manual | Page 6 Manual Version 1.0.3

Page 7

Push the clamp tab up 3 to lock the DIN-4C to the DIN rail.

Connect the DIN bus 4 to the top left terminals.

Connect the motor 5 loads to the output terminals.

For more information on wiring configurations, refer to the Dual Relay Wiring Overview.

DIN-4C Instruction Manual | Page 7 Manual Version 1.0.3

Page 8

5 Servicing the DIN-4C

The DIN-4C contains no user-serviceable parts; should the unit require a repair, it must be returned via the online form at https://returns.rakocontrols.com/contact/service-returns/.

If the DIN-4C has been returned from a repair, ensure it is operating correctly by testing the following:

Check that the input voltage matches the required specifications to ensure proper operation of the unit and load.

Use the override buttons to switch the outputs on and off. After each switch, test the voltage outputs to confirm they are functioning as expected.

Ensure that the correct box number is set on the unit as per the configuration to ensure the correct identification within the system.

Verify the communication functionality by testing the unit with either a Keypad or Rasoft Pro software.

6 Programming the DIN-4C

The DIN-4C is programmed using the Rasoft Pro programming software. A WK-HUB is required for any programming of a Rako Wired DIN system. Instructions for this can be found in the Wired System Setup Guide.

7 LED Diagnostics

7.1 Display Bootloader

When the DIN module is updating firmware, the device will be put into bootloader.

Bootloader Sleep

Once a firmware update has commenced, the bootloader will enter Bootloader Sleep and wait for the upgrade to complete.

DIN-4C Instruction Manual | Page 8 Manual Version 1.0.3

Page 9

Local Channel

When receiving data from the DIN-LINK, the DIN module will flash ‘L.’ when receiving a command.

Error

When the test button is pressed, and there is an error communicating with the DIN module, ‘E’ will appear on the display.

7.2 Output LEDs

LED Description Pattern Possible Cause 1-8 Bootloader The output is in Slow Flash ~1 seconds (Channel Specific) bootloader; this

occurs during the firmware upgrade process.

DIN-4C Instruction Manual | Page 9 Manual Version 1.0.3

Page 10

8 Installation Guidelines

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

8.1 Electrical Isolation A disconnect device must be provided in the installation and must be all-pole. It must be clearly labelled and positioned so that it is not obstructed by enclosures, wiring, or heavy equipment, ensuring easy access for maintenance and emergency disconnection. Ensure the power supply is isolated before starting any installation or maintenance; failure to do so may result in electrical shock or injury. 8.2 Mounting The DIN-4C module is designed for mounting on a DIN rail. Ensure the module is securely mounted within a compliant DIN enclosure using the appropriate fixings. 8.3 Enclosure and Environmental Protection Install the DIN-4C module in a suitably rated enclosure that protects against dust, moisture, and other contaminants according to its environment; failure to do so may lead to damage or malfunction. 8.4 Maximum and Minimum Loadings The load capacity of the DIN-4C module is load-type dependent; refer to the 'Load Types' section of the instruction manual to ensure the load is within the specified limits. Exceeding these limits may cause relay failure.

8.5 Overcurrent Protection Install appropriate overcurrent protection in line with the module, based on the electrical load and supply, to protect the module from potential short circuits or overloads.

8.6 Wiring All wiring should comply with the current local wiring regulations. This includes selecting the correct cable size, using appropriate termination methods, and ensuring mechanical protection for the wiring.

8.7 Ventilation and Cooling Ensure sufficient ventilation within the DIN enclosure to prevent overheating. Poor ventilation can lead to overheating and module failure.

DIN-4C Instruction Manual | Page 10 Manual Version 1.0.3

Page 11

8.8 Compatibility Verify that the DIN-4C module is compatible with other electrical components in the system. Incompatibility may result in malfunction, reduced performance, or damage to the module.

The DIN-4C should be connected to Rako devices only via the DIN bus.

Do not connect third-party devices to the Rako DIN bus. 8.9 Third-Party Accessories and Equipment The installer is responsible for providing the necessary cables, isolators, electrical loads, and ferrules compatible with the terminals on the DIN-4C unit.

Refer to the manufacturer's instructions for all third-party devices.

All cables must be appropriately rated for the intended load and comply with the relevant electrical standards. 8.10 Sound Pressure Levels

The DIN-4C produces negligible sound pressure levels during normal operation (<70 dB(A) at 1 meter distance). The relays emit minor audible clicking sounds during switching operations.

DIN-4C Instruction Manual | Page 11 Manual Version 1.0.3

Page 12

Appendix 1 - Wiring Options

DIN-4C Instruction Manual | Page 12 Manual Version 1.0.3

Page 13

Appendix 2 - Relay Programming Menu

To access the menu for programming the relays, right click the device on the channel list and select ‘Go to (device)’

Select ‘Relay Module’

DIN-4C Instruction Manual | Page 13 Manual Version 1.0.3

Page 14

1. Relay Timeouts Enabled by default. Defines the time (in seconds) before the relays disengage after activation. 2. Test Sends test commands to the relays. Before testing, ensure the motor wiring complies with the manufacturer’s instructions and that any required limits are set on the motor. 3. Fade Button Options No Action – Fade commands will have no effect on the motor. Enable Momentary Action – Relays engage only while the fade button is held. The relays will disengage when released. An optional setting allows the relay to latch after a specified time. Enable Latching Action – Relays engage when the button is pressed and disengage after the configured timeout (default: 127.5 seconds). 4. Fade Up / Fade Down Button Assigns which relay is controlled by the Fade Up and Fade Down commands. 5. Changeover Defines the delay between switching relays. It is recommended to leave this at the default setting, as reducing the delay may cause damage to the motor. 6. Defaults Reset for Smartphone – Restores default relay timeouts with latching action enabled. Reset for 1 Second Dry Contact – Sets relay timeouts to 1 second with momentary action. Commonly used with interfaces requiring dry contact pulses to control the motor.

DIN-4C Instruction Manual | Page 14 Manual Version 1.0.3