® Architectural Style Wallstations ntgrxwstns-3 12.12.03 Color and Finish Codes NTGRX-4B-__-__ Description 4-Button Wallstation • Used to select scenes in GRAFIK Eye Control Units. • Scene selection functionality can be selected in the field. • Status LEDs indicate which scene is selected. • Works with GRAFIK Eye 3000 and 4000 Series LEDs Control Units. • Selects scenes in just one Control Unit or a group of up to eight Control Units. • Can be ganged with the NTGRX-4S Wallstation to Scene give occupants access to 8, 12, or 16 scenes. selection Finish and Engraving Options buttons • Available with engraving to meet specific project needs. • Available in a “no-insert” version for a sleeker look. Insert Field Selected Functionality DIP Switch Settings Scene selection 5 6 buttons activate: Scenes 1 to 4 Scenes 5 to 8 Scenes 9 to 12 Scenes 13 to 16 1 R SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 2
® Architectural Style Wallstations ntgrxwstns-9 12.12.03 Specifications Power Color and Finish Codes Dimensions Low-voltage type Class 2 (PELV). Matte Finishes Front View Operating voltage: 12/24 V Direct Current. Standard – Ship in 48 hours White WH Key Design Features Ivory IV • Meets IEC 801-2. Tested to withstand 15kV Beige BE Gray GR electro-static discharge without damage or Brown BR memory loss. Black BL • Faceplate snaps on with no visible means of Metal Finishes attachment. Ship in 4 to 6 weeks • Can be ganged to share a common faceplate Bright Brass BB with NovaT*® and Vareo® Dimmers. Counts as Bright Chrome BC Bright Nickel BN a “small control” for ganging. Satin Brass SB System Communications and Capacity Satin Chrome SC Satin Nickel SN 2 3/4" • Low-voltage type Class 2 (PELV) wiring Antique Brass QB (70mm) connects Wallstations to Control Units Antique Bronze QZ Side View and other components. Anodized Aluminum Finishes • Up to 8 Control Units and up to 16 total Ship in 4 to 6 weeks Clear CLA Wallstations and/or Control Interfaces may Black BLA be linked for a total of 24 control points. Brass BRA Terminals Engraving E 4 9/16" No Insert NI (116mm) 2 Accept up to two #18 AWG (1.0mm ) typical. Also available: Environment -Custom Controls -Color Matching 32-104°F (0-40°C). Relative humidity less Ship in 4 to 6 weeks. Pricing than 90% non-condensing. may vary depending on finishes. 5/16" 1 3/8" (8mm) (35mm) Mounting Class 2 (PELV) Back View wiring DIP Switches 1-4 used to set address 5-7 used to 1234567 select function 4 1-Gang U.S. 3 Terminals for 2 Wallbox 1 Class 2 (PELV) wiring Faceplate 2 R SPECIFICATION SUBMITTAL Page Job Name: Model Numbers: Job Number:
Page 3
® Architectural Style Wallstations ntgrxwstns-10 12.12.03 Wallstation Installation DIP Switches Low-Voltage Class 2 (PELV) Wiring • Set DIP switches 1-4 to give the • Use low-voltage Class 2 (PELV) wiring to daisy-chain Wallstation a unique system address Wallstations to Control Units and other components. from 1 to 16. • Make connections inside the wallbox or in a switch/junction • Set additional DIP switches (if any) to box with a maximum wire length of 8 feet (2.5m) from the link specify function as shown on the first to the Wallstation. page of the Wallstation’s Specification Note: EGRX Wallstations have a “D” terminal for Drain. Submittal. Connect the Drain/Shield at this terminal. When used with GRAFIK Eye 3000 Control Units: 2 DIP Switch Settings • Two #18 AWG (1.0mm ) conductors for common (terminal 1) Address 1234 and 12 V Direct Current (terminal 2). Ensure that the terminal 2 1 connection is wired correctly. Refer to GRX-3000 Specification 2 Submittal. 2 • One shielded, twisted pair #18 AWG (1.0mm ) for data link 3 (terminals 3 and 4). 4 When used with GRAFIK Eye 4000 Control Units: 5 2 • Two #12 AWG (2.5mm ) conductors for common (terminal 1) 6 and 24 V Direct Current (terminal 2). These won’t fit in 7 terminals. Connect as shown. 2 • One shielded, twisted pair #18 AWG (1.0mm ) for data link 8 (terminals 3 and 4). 9 • Connect Drain/Shield as shown. Do not connect to Ground (Earth) or Wallstation. Connect the bare drain wires and cut off 10 the outside shield. 11 Data Link Wallstation Rear View (1) Shielded, twisted 12 2 pair #18 AWG (1.0mm ) 13 3: MUX 4: MUX 14 15 D: Drain/Shield 16 123456 Reserved for GRX-PRG, if present on link. (2) #12 AWG (2.5mm2) 4 3 (2) #12 AWG 2 2 1 (2.5mm ) Class 2/PELV Control Wiring 1: Common (1) #18 AWG 2: 24VFW 2 (1.0mm ) R SPECIFICATION SUBMITTAL Page 3 Job Name: Model Numbers: Job Number:
Need assistance or looking to source this item?