QS Smart Power Supply Panel (CE) Installation Instructions QSPS-P2-10-60
Page 2
QSPS-P2-10-60 230 V~ 50/60 Hz 4 A Installation Instructions (Please leave for occupant) Please read before installing. Tools Required: Wire Cutter/Stripper Power Drill Small Flat-Head Screwdriver #2 Phillips® Screwdriver NOTE: Mounting hardware is not included due to the wide variety of wall materials. Customer should determine the appropriate mounting hardware for their specific needs. Box Contents: QSPS-P2-10-60 1 Important Notes 1.1 1. All wiring must be in accordance with national and local electrical codes. 2. QSPS-P2-10-60 must be installed by a qualified electrician. 3. Ambient operating temperature: 0 to 40 °C (32 to 104 °F), 0 to 90% humidity, non-condensing. 4. This product is intended for indoor use only. 5. On power-up under unfavorable mains conditions, this device may cause interfering voltage fluctuations (flicker). To prevent such interference, the system impedance Zmax shall be 0.21 Ohms or less at the interface point (power service box). If necessary, the user can ask the public power supply company for the system impedance at the interface point. Page 1 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 3
2 Installation 2.1 1. Mount QSPS-P2-10-60 using one of the following methods (mounting hardware is not provided). Do not mount in any other orientation. a. Surface Mount - Use the keyholes located on the back of the enclosure to fasten the QSPS-P2-10-60 to the wall. Use fasteners rated for a 23 kg (50 lb) load. See illustration of QSPS-P2-10-60 . b. Recess Mount - Install a 50 mm x 100 mm (2 in x 4 in) board between the studs as a bottom support. Fasten the QSPS-P2-10-60 to the right stud and bottom support inserting fasteners through the mounting holes provided. NOTICE: The equipment 406 mm (16 in) is air-cooled. Mount in a 264 mm (10.4 in) location where the vented cover will not be blocked. 121 mm (4.8 in) A minimum of 300 mm 30 mm (1.2 in) (1 ft) is necessary. WARNING: Risk of death or serious injury. Lock the supply breaker in the OFF position before wiring to the terminal blocks. 2. Connect 230 V~ power wiring into the QSPS-P2-10-60. 375 mm (14.8 in) Remove one of the knockout tabs 445 mm (17.5 in) on the top left side of the enclosure near the input terminal blocks. Insert a strain relief into the knockout hole. Run the power wire through the strain relief to the input terminal blocks at the top left side 152 mm (6 in) of the enclosure. Tighten terminal blocks to 0.4 to 0.6 N•m (3.5 to 45 mm (1.8 in) 5 in-lbs). 50 x 100 mm (2 x 4 in) Bottom Support Note: Maximum of (1) QSPS-P2-10-60 per 15 A Breaker. Maximum feed breaker size of 15 Amps. Use only High-Magnetic breakers. Page 2 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 4
2 Installation (continued) FUSE 5X20 FUSE 5X20 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 2.2 QSPS-P2-10-60 Parts identification 230 V~ input terminal blocks FUSE FUSE 5X20 FUSE 5X20 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 Spare fuses 5x20 mm 1 2 3 4 5 6 7 8 9 10 2.5 A FUSE 5X20 FUSE 5X20 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 5X20 FUSE 5X20 FUSE 5X20 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 FUSE 1 2 3 4 5 6 7 8 9 10 4 8 FUSE5X20 FUSE 5X20 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 5X20 4-pin connector 4 8 M X X M X X FUSE 2 6 10 CO MU MUpower and communication CO MU MU 1 2 3 4 5 6 7 8 9 10 2 LINK 6 10 M X X 5X20 3 7 CO MU MUto Lutron lighting and LINK 4 8 FUSE 1 5X20 5 FUSE 9 5X20 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 M X X shading devices M X X CO MU MU 2 6 10 LINK FUSE CO MU MU M X X 3 3 7 CO MU MU 7 1 2 3 4 5 6 7 8 9 10 1 5 9 LED – Output status 5X20 (1 per output, 9 1 5 4 8 10 outputs) M X X FUSE 6 10 CO MU MU 2 1 2 3 4 5 6 7 8 9 10 LINK 3-pin connector 5X20 M X X 3 7 4 CO MU MU communication to 8 FUSE additional power supplies M X X 9 6 10 CO MU MU 1 5 2 LINK M X X 12345 6 7 8 9 10 3 7 CO MU MU 5 9 5X20 1 4 8 Diagnostic Buttons Reserved for future use M X X All Lights On CO MU MU Reserved for future use 26 10 All Lights Off LINK Diagnostic LED – Communication Link Traffic All Shades Open M X X 3 7 All Shades Close CO MU MU Status LED Power Supply Clear 15 9 Page 3 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 5
3 QS Link Wiring 3.1 Link Rules The following Link rules must be observed for proper operation. - Maximum of 100 devices (such as a GRAFIK Eye® QS Unit, QS keypad, QSPS-P2-10-60, or Sivoia® QS shade) - Maximum of 100 zones (such as a Sivoia QS shade, or a lighting zone on a GRAFIK Eye QS Unit) - Maximum 600 m (2000 ft.) of cable connecting all QSPS-P2-10-60 panels - Maximum 600 m (2000 ft.) of cable to devices wired to each QSPS-P2-10-60 - Use only cable with at least one twisted/shielded pair for communications (MUX and MUX) 3.2 Wire Length Chart Maximum devices per one output Maximum distance per one output based on wire guage 12 AWG 16 AWG 18 AWG 2 Shades + Controls 2 2 (1 mm ) (4 mm ) (1.5 mm ) GRX-CBL-346S-500 Up to 8 None seeTouch QS 1200 ft (350 m) 500 ft (150 m) 300 ft (75 m) keypads 1 Sivoia QS roller 64TM, Up to 1 roller 100, roller 200CW, seeTouch QS 500 ft (150 m) 200 ft (60 m) 125 ft (35 m) or roller 225TM keypad 2 Sivoia QS roller 64, 30 sq ft None (2.75 sq m) each 3 Sivoia QS roller 64, 20 sq ft None 200 ft (60 m) 75 ft (20 m) 50 ft (15 m) (1.8 sq m) each 2 Sivoia QS roller 100, 50 sq ft None (4.6 sq m) each Page 4 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 6
3 QS Link Wiring (continued) 3.3 Example: Multiple shades per output Sivoia QS roller 64, 2.25 sq m (25 sq ft) Up to 15 m (50 ft) of 2 Sivoia QS roller 64, 2.25 sq m (25 sq ft) 1 mm (18 AWG) 4-conductor twisted/ shielded wire Open Preset Close Open Meeting Preset Videoconf Close Afternoon A/V Night LUTRON Off seeTouch® QS Up to 75 m (250 ft) of GRAFIK Eye® QS 2 1 mm (18 AWG) 4-conductor twisted/ shielded wire Page 5 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 7
3 QS Link Wiring (continued) 3.4 Example: One shade per output Sivoia QS roller 64, 2.25 sq m (25 sq ft) Up to 30 m (100 ft) of 2 1 mm (18 AWG) 4-conductor Sivoia QS roller 64, 2.25 sq m (25 sq ft) twisted/shielded wire Up to 30 m (100 ft) of 2 1 mm (18 AWG) 4-conductor twisted/ shielded wire Open Preset Close Open Meeting Preset Videoconf Close Afternoon A/V Night LUTRON Off seeTouch® QS Up to 75 m (250 ft) of GRAFIK Eye® QS 2 1 mm (18 AWG) 4-conductor twisted/ shielded wire Page 6 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 8
4 Wiring the QSPS-P2-10-60 1 4.1 Run low voltage wire into the QSPS-P2-10-60 1.1 Remove as many knockout Input power from distribution panel tabs as necessary from the left side of the enclosure and insert strain reliefs. Hot (Live) Run the low-voltage Neutral communication wiring from Earth Ground the Lutron QS shade and lighting devices through the strain reliefs to the terminal blocks. Strip insulation wire so that Low voltage wiring 7 mm (.25 in) of bare wire is (To Lutron shade and exposed. Make sure to lighting components) tighten the screws tightly and that no insulation is inside of the terminal block. Page 7 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 9
4 1 Wiring the QSPS-P2-10-60 (continued) 4.2 Connecting Multiple QSPS-P2-10-60 Panels 1.1 Use the two 3-pin terminal blocks when connecting multiple QSPS-P2-10-60 panels. From additional QSPS-P2-10-60 To additional panels QSPS-P2-10-60 panels Device Link 4 - conductor power and communications to devices. Max 600 m (2000 ft) per QSPS-P2-10-60 Panel Link 3 - conductor communications Max 600 m (2000 ft) connecting all QSPS-P2-10-60 panels. Page 8 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 10
FUSE 5X20 FUSE 5X20 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 5 Diagnostics The QSPS-P2-10-60 provides built-in diagnostics to help troubleshoot and verify your installation. 5.1 Output status LEDs FUSE 1 2 3 4 5 6 7 8 9 10 Each output has a status LED to indicate if the output is properly powered. If an output becomes overloaded, its status LED will blink to indicate the fault condition. 5X20 Press the “Power Supply Clear” button after the fault condition has been cleared and the LED will stop blinking. Output status LEDs 4 8 FUSE5X20 FUSE 5X20 1 10 9 8 7 6 5 4 3 2 1 M 10 9 8 7 6 5 4 3 2 X X 2 6 10 CO MU MU LINK M X X FUSE 5X20 FUSE 5X20 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 3 7 CO MU MU LED FUSE 1 2 3 4 5 6 7 8 9 10 5X20 4 8 M X X 2 6 10 CO MU MU LINK M X X 3 7 CO MU MU 1 5 1 5 9 9 If an output status LED has turned off, the fuse will need to be replaced. The QSPS-P2-10-60 comes with two spare 5x20 mm 2.5 A fuses. Fuses Spare fuses FUSE 123 4 5 6 7 8 9 10 FUSE 5X20 FUSE 5X20 1 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 5X20 4 8 FUSE 1 2 3 4 5 6 7 8 9 10 5X20 4 8 M X X CO MU M MU X X 2 6 10 CO MU MU 2 6 10 LINK M X X 3 7 CO MU MU LINK 1 5 9 M X X 3 Page 9 7 CO MU MU Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions 1 5 9
Page 11
5 Diagnostics (continued) 5.2 Communications Link LEDs The QSPS-P2-10-60 has four diagnostic LEDs for the communications link. Diagnostic LEDs Reserved for future use Reserved for future use Link Traffic This LED will blink green to indicate that devices are communicating. Status LED This LED indicates that the panel is operating properly. If this LED is off, check your wiring. 5.3 Verify Communications To verify the communications of your system, tap, hold (5 seconds), tap, hold (5 seconds) the All Shades Open button. The QSPS-P2-10-60 is now trying to communicate with all other devices. All EDUs communicating on the link will wiggle and flash their green LED quickly. If you discover any EDUs that are not wiggling, verify that the EDU is powered and wired properly. Link Diagnostics Mode will automatically time out after 10 minutes. To exit Link Diagnostics Mode, press and hold the All Shades Open button for 5 seconds. Page 10 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 12
Notes: Page 11 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 13
Notes: Page 12 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 14
Notes: Page 13 Sivoia® QS QSPS-P2-10-60 (CE) Installation instructions
Page 15
Limited Warranty SCOPE incorrect line voltages fuses or circuit breakers; (b) failure to This limited warranty (“Warranty”) covers the Lutron supplied (a) install, maintain and operate the System pursuant to the Sivoia® QS Shade System (“Sivoia® QS Shade System”), (b) Sivoia operating instructions provided by Lutron and the applicable QED® Shade System (“Sivoia QED® Shade System”), (c) manual provisions of the National Electrical Code and of the Safety shade system and (d) alternating current or a/c shade system (each Standards of Underwriter’s Laboratories; (c) use of incompatible of the foregoing being a “System”). Customer acknowledges and devices or accessories; (d) improper or insufficient ventilation; (e) agrees that use of the System constitutes acceptance of all terms unauthorized repairs or adjustments or alterations; (f) vandalism; and conditions of this Warranty. (g) an act of God, such as fire, lightning, flooding, tornado, earthquake, hurricane or other problems beyond Lutron’s LIMITED WARRANTY control; or (h) direct exposure to corrosive materials. Subject to the exclusions and restrictions described below, Lutron warrants that each System will be free from manufacturing defects 2. On-site labor costs to diagnose issues with, and remove, repair, from the date of shipment by Lutron for a period of (a) one year replace, adjust, reinstall and/or reprogram the System or any of as to the wall controls, interfaces and system accessories of the its components. Sivoia® QS Shade System (“External Sivoia® QS Components”) and (b) eight years as to the other Systems and the electronic drive unit, 3. Components and equipment external to the System, such as, shade fabric and shade hardware of the Sivoia® QS Shade System. non-Lutron lighting and automation systems; building wiring If any manufacturing defect exists in the External Sivoia® QS audio-visual equipment; and non-Lutron time clocks, Components, so long as Customer promptly notifies Lutron of the photosensors and motion detectors. defect within the one year warranty period and, if requested by 4. The cost of repairing or replacing other property that is damaged Lutron, returns the defective part(s), Lutron will, at its option, either when any System does not work properly, even if the damage repair the defective part(s) or provide comparable replacement was caused by the System. part(s). If any manufacturing defect exists in any of the components of a System other than the External Sivoia® QS Components, so THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS long as Customer promptly notifies Lutron of the defect within the WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING eight year warranty period and, if requested by Lutron, returns THE IMPLIED WARRANTIES OF MERCHANTABILITY AND the defective part(s), Lutron will, at its option, either repair the OF FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED defective part(s) or issue a credit to the Customer against the TO EIGHT YEARS FROM THE DATE OF SHIPMENT, EXCEPT purchase price of comparable replacement part(s) purchased THAT SUCH IMPLIED WARRANTIES ARE LIMITED TO ONE from Lutron as provided below: YEAR FROM THE DATE OF SHIPMENT AS TO THE Number of years Percentage of cost of EXTERNAL Sivoia QS COMPONENTS. from date replacement parts NO LUTRON AGENT, EMPLOYEE OR REPRESENTATIVE HAS of shipment credited by Lutron ANY AUTHORITY TO BIND LUTRON TO ANY AFFIRMATION, Up to 2 100% REPRESENTATION OR WARRANTY CONCERNING THE SYSTEMS. UNLESS AN AFFIRMATION, REPRESENTATION More than 2 but OR WARRANTY MADE BY AN AGENT, EMPLOYEE OR not more than 5 50% REPRESENTATIVE IS SPECIFICALLY INCLUDED HEREIN, OR IN STANDARD PRINTED MATERIALS PROVIDED BY More than 5 but LUTRON, IT DOES NOT FORM A PART OF THE BASIS OF not more than 8 25% ANY BARGAIN BETWEEN LUTRON AND CUSTOMER AND WILL NOT IN ANY WAY BE ENFORCEABLE BY CUSTOMER. More than 8 0% IN NO EVENT WILL LUTRON OR ANY OTHER PARTY BE LIABLE FOR EXEMPLARY, CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES (INCLUDING, BUT NOT LIMITED Replacement parts for the System provided by Lutron or, at its sole TO DAMAGES FOR PERSONAL INJURY, FAILURE TO MEET discretion, an approved vendor may be new, used, repaired, ANY DUTY, INCLUDING OF GOOD FAITH OR REASONABLE reconditioned, and/or made by a different manufacturer. CARE, NEGLIGENCE, OR ANY OTHER LOSS WHATSOEVER), NOR FOR ANY REPAIR WORK UNDERTAKEN WITHOUT EXCLUSIONS AND RESTRICTIONS LUTRON’S PRIOR WRITTEN CONSENT ARISING OUT OF This Warranty will be void, and Lutron and its suppliers will have no OR IN ANY WAY RELATED TO THE INSTALLATION, responsibility under this Warranty, if Lutron or its representatives DEINSTALLATION, USE OF OR INABILITY TO USE THE cannot access any components of the System to inspect, diagnose SYSTEM OR OTHERWISE UNDER OR IN CONNECTION problems with or repair the System or any of its components as a WITH ANY PROVISION OF THIS WARRANTY, EVEN IN THE result of concealment or inaccessibility of such components within EVENT OF THE FAULT, TORT (INCLUDING NEGLIGENCE), a building structure. STRICT LIABILITY, BREACH OF CONTRACT OR BREACH OF This Warranty does not cover, and Lutron and its suppliers are not WARRANTY OF LUTRON OR ANY OTHER PARTY, AND EVEN responsible for: IF LUTRON OR SUCH OTHER PARTY WAS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 1. Damage, malfunction or inoperability diagnosed by Lutron or a NOTWITHSTANDING ANY DAMAGES THAT CUSTOMER Lutron approved third party as caused by normal wear and tear, MIGHT INCUR FOR ANY REASON WHATSOEVER abuse, misuse, incorrect installation, neglect, accident, (INCLUDING, WITHOUT LIMITATION, ALL DIRECT DAMAGES interference or environmental factors, such as (a) use of AND ALL DAMAGES LISTED ABOVE), THE ENTIRE Page 14 Sivoia® QS QSPS-P2-10-60 Installation instructions
Page 16
LIABILITY OF LUTRON AND OF ALL OTHER PARTIES Technical Assistance UNDER THIS WARRANTY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, USE, WORLD ADDITIONAL LUTRON REPAIR, OR REPLACEMENT OF THE SYSTEM, AND HEADQUARTERS SALES OFFICES: CUSTOMER’S SOLE REMEDY FOR THE FOREGOING, WILL Lutron Electronics Co., Inc. BE LIMITED TO THE AMOUNT PAID BY CUSTOMER FOR 7200 Suter Road Germany THE SYSTEM. THE FOREGOING LIMITATIONS, EXCLUSIONS Coopersburg, PA 18036 Tel: +49.309.710.4590 AND DISCLAIMERS WILL APPLY TO THE MAXIMUM EXTENT ALLOWED BY APPLICABLE LAW, EVEN IF ANY REMEDY United States Fax: +49.309.710.4591 FAILS ITS ESSENTIAL PURPOSE. Tel: +1.610.282.3800 FREEPHONE Fax:+1.610.282.1243 00800.5887.6635 THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM ASIAN France STATE TO STATE. SOME STATES DO NOT ALLOW HEADQUARTERS Lutron Ltc, S.A.R.L.-Paris LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY Lutron GL Ltd. 90 rue Villiers LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL 15 Hoe Chiang Road 92300 Levallois Perret, OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. #07-03 Tower Fifteen France Singapore 089316 Tel: +33.1.41.05.42.80 WARRANTY CLAIMS, TECHNICAL ASSISTANCE AND Tel: +65.6220.4666 Fax: +33.1.41.05.01.80 WARRANTY INFORMATION. Fax: +65.6220.4333 FREEPHONE: 0800.90.12.18 Contact the Lutron Technical Support Center at the numbers lutronsea@lutron.com lutronfrance@lutron.com provided below or your local Lutron sales representative with questions concerning the installation or operation of the System EUROPEAN Spain-Madrid or this Warranty, or to make a warranty claim. Please provide the HEADQUARTERS Tel: +34.91.567.84.79 exact model number when calling. Lutron EA Ltd. Fax: +34.91.567.84.78 U.S. and foreign patents pending. 6 Sovereign Close FREEPHONE 0900.948.944 London, E1W 3JF Lutron, the Sunburst logo, Sivoia, and Sivoia QED are registered United Kingdom Spain-Barcelona trademarks of Lutron Electronics Co., Inc. Tel: +44.(0)20.7702.0657 Tel: +34.93.496.57.42 Fax: +44.(0)20.7480.6899 Fax: +34.93.496.57.50 FREEPHONE 0900.948.944 CUSTOMER SERVICE/ ORDERING Hong Kong UK +44.(0)20.7702.0657 – Tel: +852.2104.7733 09.00 - 18.00 GMT Fax: +852.2104.7633 www.lutron.com/shadingsolutions USA +1.610.282.3800 – 08.00 - 20.00 EST Beijing USA and Canada (24 hrs/7days): Tel: +86.10.5877.1817 CUSTOMER SERVICE Fax: +86.10.5877.1816 call: 800.523.9466 /E-MAIL shadinginfo@lutron.com Singapore Other countries (8 a.m. – 8 p.m. EST) LUTRON GL Ltd. - call: +1.610.282.3800 TECHNICAL SUPPORT Singapore & SERVICES 15 Hoe Chiang Road fax: +1.610.282.3090 USA +1.610.282.3800 – #7-03 Tower 15 24 hours/7 days Singapore 089316 email: shadinginfo@lutron.com UK +44.(0)20.7702.0657 Tel: +65.6220.4666 09.00 - 18.00 GMT Fax: +65.6220.4333 ©2008 LUTRON Electronics Co., Inc. INTERNET: Japan Printed in the U.S.A. www.lutron.com Tel: +81.3.5575.8411 P/N 045-131-12 REV. A Fax: +81.3.5575.8420