SPS-V-6 - QA2-60 SLIDING PANEL MECHANISM - VERTICAL TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 1 FUTUREAUTOMATION

Page 2

SPS-V-6 - QA2-60 SLIDING PANEL MECHANISM - VERTICAL SPS-V - VERTICAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN HEIGHT MAX SCREEN HEIGHT SPS-V-5 Vertical - Single Panel 700 [27 9/16"] 800 [31 1/2"] SPS-V-6 Vertical - Single Panel 801 [31 9/16"] 950 [37 3/8"] SPS-V-7 Vertical - Single Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-V-8 Vertical - Single Panel 1101[ 43 3/8""] 1250[ 49 3/16"] SPS-VS - VERTICAL SPLIT - DOUBLE PANEL SPS-VS-6 Vertical - Double Splitting Panel 800 [31 1/2"] 950 [37 3/8"] SPS-VS-7 Vertical - Double Splitting Panel 951 [37 7/16"] 1100[ 43 5/16"] SPS-VS-8 Vertical - Double Splitting Panel 1101[ 43 3/8""] 1250[ 49 3/16"] SPS-HZ - HORIZONTAL - SINGLE PANEL MODEL DESCRIPTION MIN SCREEN WIDTH MAX SCREEN WIDTH SPS-HZ-6 Horizontal - Single Panel 1400 [55 1/8"] 1600 [63"] SPS-HZ-7 Horizontal - Single Panel 1601 [63 1/16""] 1850 [72 13/16"] SPS-HZ-8 Horizontal - Single Panel 1851 [72 7/8"] 2100 [82 11/16"] SPS-HZS - HORIZONTAL SPLIT- DOUBLE PANEL SPS-HZS-6 Horizontal - Double Splitting Panel 1400 [55 1/8"] 1600 [63"] SPS-HZS-7 Horizontal - Double Splitting Panel 1601 [63 1/16""] 1850 [72 13/16"] SPS-HZS-8 Horizontal - Double Splitting Panel 1851 [72 7/8"] 2100 [82 11/16"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 2 FUTUREAUTOMATION

Page 3

SPS-V-6 - QA2-60 SLIDING PANEL MECHANISM - VERTICAL 2. Panel Retracts 1. Panel Closed SPECIFICATION MEASUREMENTS Minimum Screen Height 801 [31 1/2"] Maximum Screen Height 950 [37 3/8"] Minimum Screen Width 1400 [55 1/8"] Maximum Screen Width 1900 [74 13/16"] Maximum Moving Panel Weight 40Kg (88lbs) Maximum Screen Weight 80Kg (176lbs) Total Mechanism Weight TBC Packaging Dimensions (LxWxH) TBC Shipping Weight TBC 3. Panel Lifts 4. Screen Advances Movement Type Motorised Power Supply Required 110V - 240V AC Power Consumption Max. 120W Power Consumption Standby 3W Mounting Patterns Supported VESA 400, 300, 200 W x 400, 300, 200 H Control Options IR Remote, Contact Closure Product Options / Features AB pairing option Package Contents Mechanism, IR remote control, Bolt Pack Marine Suitable Yes (Indoor) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 3 FUTUREAUTOMATION

Page 4

To determine the cavity height use the following SPS-V-6 - QA2-60 formula: SECTION A-A SLIDING PANEL MECHANISM - VERTICAL Cavity Height = (2 x Screen Height) + 80 SECTION B-B If the cavity height is larger than the min. cavity height 5 5/16" 5 5/16" CABINET DIMENSIONS - WIDTH AND HEIGHT Maximum Screen Height shown below that is your cavity height if not use the 135 135 min. cavity height. Internal Cabinet Width = Screen Width + 280 Screen Height Install Height SPS-V SizeScreen HeightInstal Height B 801 [31 1/2"] 950 [37 3/8"] (2 x Screen Height) + 190 50 1610 [63 3/8"] 1 15/16"Clearance SECTION B-B Minimum Screen Height Size 5 50 Screen Width Install width (2 x Screen Height) + 190 1 15/16"Clearance 1400 [55 1/8"] 1900 [74 13/16"] Screen Width + 280 1760 [69 5/16"] Size 6(2 x Screen Height) + 190 Screen Height 5 5/16" 5 5/16" 135 135 Moving Panel Height = SECTION A-A 2110 [83 1/16"] A A Internal Cabinet Width = Screen Width + 280 Size 7(2 x Screen Height) + 190 Screen Height B Moving Panel Height = 2250 [88 9/16"] Opening Width = Opening Height = Screen Height +10 Size 8(2 x Screen Height) + 190 13/16"20 Screen Width +10 20 68 1/2"1740 68 1/2"1740 SPS-V SizeScreen HeightInstal Height 13/16" Mechanism Height Mechanism Height Install Height = (2 x Screen Height) + 190 B 1610 [63 3/8"] Size 5 Install Height = (2 x Screen Height) + 190 (2 x Screen Height) + 190 A A Opening Height Opening Height The SPS-V will always require 110mm [4 5/16"] below the opening. 1760 [69 5/16"] The remaining height required is determined either by the size of the height of the screen or the height of the mechanism. Size 6(2 x Screen Height) + 190 110 110 4 5/16" 4 5/16" The install height is calculated be the following formula (2 x Screen Height) + 190. If this comes out under the mechanism height the mechanism height needs to Opening Width = Opening Height = Screen Height + 10 be used instead. 2110 [83 1/16"] Screen Width + 10 Size 7(2 x Screen Height) + 190 TECHNICAL SHEET B 2250 [88 9/16"] UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 4 FUTUREAUTOMATION Size 8(2 x Screen Height) + 190

Page 5

SPS-V-6 - QA2-60 SLIDING PANEL MECHANISM - VERTICAL 1 3/16" Screen - IN CABINET DIMENSIONS - DEPTH Screen - OUT 30 Moving Panel The minimum depth of 245mm [9 5/8"] allows for a Thickness D maximum screen depth of 30mm [1 3/16"]. A Screens with a greater thickness will need the cabinet 1 15/16" depth to increase i.e. a 100mm [3 15/16"] thick screen 50 will require a cabinet of 315mm [12"]. Max. Front Panel and Batten Thickness Screens thinner than 30mm [1 3/16"] must still use the minimum 245mm [12 3/8"] cabinet depth. 13/16" DETAIL D 20 SCALE 1 : 3 Recommended batten to support Front Panel A front panel above opening Thickness 2 9/16" 65 A Retract 2 9/16" The moving panel retracts back by 65mm [2 9/16"] 65 before rising. For this reason it is advised the front Retract panel work and support batten is no more than 50mm [1 15/16"] thick to give 15mm [9/16"] clearance. A Thicker panels are possible, but will add to the cabinet depth and require customisation to the mechanism design. Recommended batten to support front panel above opening 9 5/8" 245 Minimum Internal Cabinet Depth TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 5 FUTUREAUTOMATION

Page 6

SPS-V-6 - QA2-60 SLIDING PANEL MECHANISM - VERTICAL CABINET DETAILS INVERTED Screen Height Install Height 801 [31 1/2"] 950 [37 3/8"] (2 x Screen Height) + 190 B 4 5/16"110

Screen Width Install width Opening Width = 1900 [74 13/16"] Screen Width + 280 1400 [55 1/8"] Screen Width +10 The SPS-V can be inverted so the panel retracts the drops instead. The mechanism used is the same as in the original orientation, the mechanism is just rotated through 180 . Opening Height Opening Height = Screen Height +10 1. Panel Retracts 2. Panel Drops 68 1/2"1740 A A Mechanism Height 13/16"20

Install Height = (2 x Screen Height) + 190 Opening Height = Screen Height +10 Opening Width = Screen Width +10 B 1 15/16"50ClearanceMoving Panel Height = Screen Height The SPS-V will always require 110mm [4 5/16"] below the opening. Internal Cabinet Width = Screen Width + 280 5 5/16" 5 5/16" 135 The remaining height required is determined either by the size of the height of 135 SECTION B-B the screen or the height of the mechanism. The install height is calculated be the following formula (2 x Screen Height) + 190. If this comes out under the mechanism height the mechanism height needs to TECHNICAL SHEET be used instead. SECTION A-A UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 SCALE 1 : 16 WWW NET . . SHEET 6 FUTUREAUTOMATION

Page 7

SPS-V-6 - QA2-60 A SLIDING PANEL MECHANISM - VERTICAL DEPTH OVERWRITTEN QA2-60 - QUAD ARM QA2 - SERVICE QA2 - OUT QA2 - IN The QA2 has a service mode that can be used during installation and servicing of the mechanism and the screen. QA2 - SWIVEL This allows the screen to be advanced out from the wall to provide access to rear of the screen and inside the mechanism A during fitting. A 5 1/2"140

40° E E A A 27 9/16"700Max Mount Height A Maximum QA2 swivel is 75 . 23 5/8" VESA 200 [7 7/8"] TO 800 [31 1/2"] However depending on the screen and cabinet 600 VESA 100 [3 15/16"] TO 600 [23 5/8"] Max Mount Width depth this will need to be reduced to prevent the screen being obscured by the cabinet. 5 1/2" 36 3/16" 140 919 TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 7 FUTUREAUTOMATION

Page 8

SPS-V-6 - QA2-60 SLIDING PANEL MECHANISM - VERTICAL CABINET DETAILS & ACCESS The SPS mechanism requires certain access for installation and to be serviced. For installation the top panel must be removable to provide access to all the fixing points of the SPS mechanism. Top Panel (removable for installation) For servicing the best option is to have the areas to the left and right of the opening on hinges. This will provide enough access to everything that will be needed to service and maintain the mechanism. Alternatively the side panels could be made to be easily removable on suitable catches / fixings. The Moving Panel Mechanism mounts to the side walls of the cabinet, and the Advance Bracket mounts to the back of the cabinet. It is essential that these surfaces can take the weight of the mechanism, moving panel and screen. The mechanism is supplied with a control box on a 3m [10'] flying lead. This must be fitted in an easily accessible location. This will be the first item to be checked if there is an issue with the mechanism. Mains power and control connections (IR sensor / receiver, contact closure) are all made at the control box. QA2-60 Hinging side panel (removable for service & maintenance) Moving panel bracket Hinging side panel (removable for service & maintenance) Moving Panel Mechanism Motor RS232 Link Mechanism Cables Moving panel bracket Power Cables Control box wiring loom must be routed to the bottom left corner of the cabinet Telescopic Drive shaft To Mains Power TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 8 FUTUREAUTOMATION

Page 9

SPS-V-6 - QA2-60 SLIDING PANEL MECHANISM - VERTICAL CONTROL BOX NOTE: RS232 CONTROL METHOD UNAVAILABLE. 8 1/8"207

RS232 PORT IR OUTPUT INDICATOR LED CONTACT CLOSURE PORT IR LEAD INPUT EMERGENCY STOP 3.5mm [0.14"] JACK max CONNECTOR CABLE LOOM 20 LENGTH APPROX 13/16" 118 1/8" 8 CORE CABLE 3000 SPS SWITCHES 10mm [3/8"] dia. EU SPEC: 0.5mm² US SPEC: 20AWG 1/4" 7

5/16"8 4 CORE CABLE 2 CORE CABLE 52 SPS MOTOR 2 1/16" SPS MOTOR 10mm [0.4"] dia. MAINS INPUT 10mm [3/8"] dia. EU SPEC: 0.75mm² EU SPEC: 4mm² 5 US SPEC: 18AWG 3/16" 5 7/8" US SPEC: 12AWG 150 8 CORE CABLE ADVANCE BRACKET NOTES 10mm [3/8"] dia. EU SPEC: 0.5mm² US SPEC: 20AWG • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 9 FUTUREAUTOMATION

Page 10

SPS-V-6 - QA2-60 SLIDING PANEL MECHANISM - VERTICAL INSTALLATION OVERVIEW Up Switch 3 11/16" 94 3 11/16" 3 11/16" 3. Run the mechanism, adjust the up 94 94 switch so that the carriages moves the height of the moving panel + 25mm [1"]. 3 11/16" 110 110 94 1. Mount the mechanism side Rear View 4 5/16" 4 5/16" channels to the side walls of the cabinet. Ensure the mechanism mount brackets are positioned 4 5/16" 110 10mm back from the edge of the front panels. C 4 5/16" Up Switch Adjustment 110 Loosen the bolt and slide the switch striker to the desired Down Switch position. Ensure the bolt is tightened after adjustment. Switch Striker 2. Install the telescopic drive shaft between both 4. Mount the moving panel to the sides of the mechanism. Ensure that the moving panel brackets 110mm from moving panel brackets are at the same height. the base of the moving panel. 5. mount the moving panel back onto the mechanism, use the slots in the mount brackets to align the panel and get it into the desired position TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 10 FUTUREAUTOMATION

Page 11

SPS-V-6 - QA2-60 SLIDING PANEL MECHANISM - VERTICAL INSTALLATION OVERVIEW 4. Mount the moving panel to the moving panel brackets 110mm 5. Mount the moving panel back onto the mechanism, use the slots in the from the base of the moving panel and 94mm in from the edge. mount brackets to align the panel and get it into the desired position. 3 11/16" 3 11/16" 3 11/16" 94 94 94 110 110 Rear View of moving panel 4 5/16" 4 5/16" 3 11/16" 94 4 5/16" 110 Moving panel bracket 4 5/16" Recommended to use 5mm 110 shims to align the moving panel with the base of the aperture. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 002 WWW NET . . SHEET 11 FUTUREAUTOMATION