Page 1

ISSUE 003 SHEET 1 of 4 Technical Sheet SAC-T - Smart Airflow Control - Tray The Smart Airflow Control range is designed to regulate airflow around equipment in AV racks or in confined spaces. The SAC-T acts as a shelf for equipment (e.g. AV receivers) which forces airflow upwards through the unit to improve airflow aiding the natural convection inside the space. Units can be combined to further increase airflow. DESIGN HIGHLIGHTS • Temperature controlled variable fan state & speed with equipment overheat alarm • Near silent operation with vibration isolating rubber mounts • Height efficient design to maximise use of space within rack / cabinet • Optional 19" Rack mounting supplied (1U) • Self contained unit with onboard electronics for simple installation OPTIONS • Custom sizes available • Any RAL colour available WARNING It is the responsibility of the installer to warn all potential end users of the dangers of interfering with mechanisms during operation www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

Page 2

ISSUE 003 SHEET 2 of 4 Technical Sheet SAC-T - Smart Airflow Control - Tray Temperature Sensor Mount General Dimensions 1.5 0.2 39 Sophisticated electronics 4.5 allow for a favourite viewing 17.1 position to be programmed 434 via the IR remote control. 0.8 Mechanism allows up to 20 750mm extension of screen centre from wall. All the power and signal 1.9 cables for screen and 49 mechanism can be concealed within the bracket. Mechanism can be reversed from a left to a right - handed or from a right to a left - handed bracket simply and quickly during the installation process. Super quiet and smooth action from parallel to wall out to 90 maximum movement. Available with Marine Lock to safely lock bracket against 2.1 wall when not in viewing position. 54 Standard mechanism with VESA 400 mounting is only 90mm deep. Group A or UNI-60 mount adds 19" RACK WING MOUNTS 20mm to make the total depth 15.9 of bracket only 110mm. 19.1 404.7 484 1.3 31.8 Optional 19" Rack 0.1 Mount Wing R3.5 www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565 ON BOARD ELECTRONICS

Page 3

ISSUE 003 SHEET 3 of 4 Technical Sheet SAC-T - Smart Airflow Control - Tray Design Highlights Temperature sensor & bracket on flying lead C Fan finger guard to be fixed inside the Sophisticated electronics AV cabinet allow for a favourite viewing position to be programmed via the IR remote control. Mechanism allows up to 750mm extension of screen centre from wall. All the power and signal cables for screen and mechanism can be concealed within the bracket. Mechanism can be reversed from a left to a right - handed or from a right to a left - handed bracket simply and quickly during the installation process. Super quiet and smooth action from Onboard parallel to wall out to 90 maximum Temperature sensor jack input electronics movement. LCD display screen for function settings Available with Marine Lock IEC power input to safely lock bracket against Up Key

+ wall when not in viewing position. Rubber feet Standard mechanism with VESA 400 mounting is only 90mm deep. Group A or UNI-60 mount adds 20mm to make the total depth of bracket only 110mm. Down Key

- Menu Key Optional 19" rack wing mounts Extra quiet fans mounted on rubber fixings to isolate vibration Display Key www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565

Page 4

ISSUE 003 SHEET 4 of 4 Technical Sheet SAC-T - Smart Airflow Control - Tray Operating Instructions DISPLAY Function: 1. Each press of the 'DISPLAY' button will cycle the display through the following: • "Current Temp" - Default • "Lowest Temp" - Displayed for 3 seconds • "Highest Temp" - Displayed for 3 seconds 2. In order to reset the values recorded for Lowest Temp and Highest Temp press the '+' and '-' buttons simultaneously whilst displaying either value. The recorded values will now change to reflect the current temperature and be displayed on the screen. MENU Function: 1. Each press of the 'MENU' button will cycle the display through the following: • "Set ON at" - The temperature at which the first pair of fans activates • "Set BOOST at" - The temperature at which the second pair of fans activates • "Set OFF at" - The temperature at which any fans will deactivate • "Set ALARM at" - The temperature at which the alarm will sound and below which the alarm will turn off • "Set SCALE" - Toggles the display between Celsius and Fahrenheit 2. Use the '+' and '-' buttons to adjust any of the above settings. www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565