PSE90 MOTORISED ARTICULATED TV WALL MOUNT INSTALLATION INSTRUCTIONS ISSUE 027
Page 3
SAFETY DISCLAIMER IMPORTANT SAFETY INSTRUCTIONS BELOW WARNING: Failure to provide adequate structural strengthening, prior to installation can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure the structure to which the component is affixed can support four times the weight of the component and any additional apparatus mounted to the component. WARNING: Do not exceed the weight capacity for this product as listed below. This can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure that the total combined weight of all attached components does not exceed that of the maximum figure stated. WARNING: Risk of death or serious injury may occur when children climb on audio and/or video equipment or furniture. A remote control or toys placed on the furnishing may encourage a child to climb on the furnishing and as a result the furnishing may tip over on to the child. WARNING: Risk of death or serious injury may occur. Relocating audio and/or video equipment to furniture not specifically designed to support audio and/or video equipment may result in death or serious injury due to the furnishing collapsing or over turning onto a child or adult. WARNING – RISK OF INJURY! Only for use with equipment weighing 132LBS (59KG) OR LESS. Use with heavier projectors/equipment may lead to instability causing tip over or failure resulting in death or serious injury. Bracket Suitable for Residential and Commercial Use. ADDITIONAL WARNINGS: 1. Keep all documentation/instructions after fitting. 2. Read all technical instructions fully before installation and use. It is the installer’s responsibility to ensure that all documentation is passed on to the end user and read fully before operation. 3. Do not use near water or outdoors unless the product has been specifically designed to do so. 4. Protect any cables or cords being used near this bracket from being walked on or pinched to prevent damage and risk of injury. 5. Use this product only for its intended purpose as described in the product instructions and only use attachments/ accessories specified by the manufacturer. 6. Do not operate the product if it is damaged in any way, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Contact the original installer/manufacturer to arrange repair or return. WARNING - To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Clean only with a dry cloth and always unplug any electrical items being used in conjunction with this product before cleaning. Future Sound & Vision trading as Future Automation intend to make this and all documentation as accurate as possible. However, Future Automation makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without prior notice or obligation of any kind. Future Automation makes no representation of warranty, expressed or implied, regarding the information contained herein. Future Automation assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document. 1
Page 4
PRODUCT WARRANTY & RISK ASSESSMENT WARRANTY INFORMATION WARNING - The warranty offered for this product shall be annulled if the product is used improperly or in a way that is in breach of our Terms of Service. Future Automation provides warranty for the mechanism you purchased for the period of 24 months from the date of purchase, provided that it isn’t used for unintended purposes. Under the warranty, Future Automation aims to either solve the issue remotely (via telephone or email support) or if the mechanism requires a part, arrange a visit to your premises by a Future Automation approved engineer or send replacement items where appropriate. Warranty repairs will be carried out as quickly as possible, but subject to parts availability. This warranty period is respectively extended for the period of a repair. A malfunctioning product must be cleaned and placed into suitable packaging to protect against transit damage before organising delivery to a repair workshop. All the complaints about defects must be submitted to the vendor/installer that sold this product, rather than directly to the manufacturer. Any part of your system that needs to be replaced during a warranty repair becomes the property of Future Automation. The warranty does not cover the following: • Damages resulting from improper product use or maintenance. • Repairs carried out by unauthorized persons. • Natural wear and tear during operation. • Damages caused by the buyer. • Accidental damages caused by a customer or damages caused as a result of careless attitude or usage, or damages caused by natural disasters (natural phenomena). • Any electrical, or other environmental work external to your Future Automation mechanism including power cuts, surges etc. • Additional items not supplied by Future Automation although they may have been supplied together by the retailer • Any 3rd party software products controlling your mechanism • Any transfer of ownership. Warranty is provided only to the initial purchaser. • Compensation for loss of use of the product, and consequential loss of any kind. A separate Safety and Servicing Information document is provided with these instructions (additional copies can be found at www.futureautomation.co.uk/safety), and this document MUST be filled out by the approved Future Automation Dealer who is installing the product. This Warranty Sheet must be held by the end user for the duration of the products life and will be referred to during servicing or warranty queries. The Safety and Servicing Information document also contains two Service History Forms that must be filled in by the approved Future Automation dealer who is performing the first required yearly service of this product. One copy of the Service History Form must be held by the customer (along with the Warranty Sheet) and a duplicate copy must be held by the approved Future Automation dealer that performed the service. Missing and/or mismatching documents may delay or invalidate warranty claims. Additional Service History Forms can be found on the Future Automation website for further yearly services. RISK ASSESSMENT INFORMATION It is the installer’s responsibility to perform a risk assessment of installed products. Future Automation can provide guidelines to installers/dealer about what should be included in a risk assessment, but due to the individual nuances of each location/site, Future Automation cannot provide a full list of areas to risk assess. For full risk assessment and safety information please view our Safety and Servicing guide available at www.futureautomation.net/safety 2
Page 5
GUIDE CONTENTS SAFETY DISCLAIMER 1 PRODUCT WARRANTY & RISK ASSESSMENT 2 GUIDE CONTENTS 3 PACKAGE CONTENTS 4 IMPORTANT SETUP INFORMATION 5 INITIAL TESTING 6 CALCULATING MOUNTING HEIGHT 7 OPENING THE BRACKET 8 WALL MOUNTING 9 CABLE ROUTING 10 SCREEN MOUNTING 11 FINAL CHECKS 12 MECHANISM PRESETS 13 INFRARED (IR) 14 CONTACT CLOSURE 15 RS232 CONTROL 16 NOTES 17 3
Page 6
PACKAGE CONTENTS 1 - PSE90 MECHANISM 1.1 - SCREEN MOUNT PLATE 1.2 - WALL MOUNT PLATE 1.3 - MECHANISM COVER 1.4 - LINK ARM 2 - INFRARED (IR) REMOTE CONTROL ITEMS NOT SHOWN ON PAGE 3 - PSE90 CONTROL BOARD (INSIDE PSE90 MECHANISM) 4 - PSE90 ACCESSORY PACK 4.1 - X2 AAA BATTERIES 4.2 - MAINS POWER LEAD 4.3 - INFRA-REF CONTROL LEAD 4.4 - CAT5 LEAD WITH RJ45 CONNECTOR 4.5 - SCREEN FIXINGS PACK (MULTI-PACK OF NUTS, BOLTS AND WASHERS) 1.4 1 1.2 1.3 2 1.1 4
Page 7
IMPORTANT SETUP INFORMATION PLEASE READ THIS INFORMATION BEFORE YOU BEGIN. THIS MECHANISM WILL NOT OPERATE DIRECTLY OUT OF THE BOX. The electronics have been disconnected to allow you to manually move the mechanism during installation without damaging the control board. Once you have installed the mechanism in situe, please refer to this page to complete the final setup. Once the green Phoenix connector is plugged in the mechanism should NOT be moved by hand. Doing so will cause damage to the control board. Control boards damaged by manually moving the mechanism, without first removing the Phoenix connector will NOT be covered under the Future Automation warranty. 1 • Disconnect mains power and then remove the 4 x M4 bolts that secure the rear arm cover to the PSE90. 2 • Remove the internal control board cover by removing the 4 x M4 bolts and unplugging the IR jack. 3 • Locate and plug in the green Phoenix connector to the control board. 4 • Re-attach all cover panels and the IR lead. 5
Page 8
INITIAL TESTING Before installing of the PSE90 mechanism, the following should be checked; • There is no damage to any part of the PSE90 mechanism, control board, or wiring. • All internal and external mechanism wiring is secure. • The mechanism is in the fully CLOSED position. • The mechanism operates correctly. This can be tested by moving the mechanism between the CLOSED and OPEN positions using the IR remote (Refer to page 14 for operating instructions) WARNING: THE PSE90 MECHANISMDOES NOT HAVE AN ANTI-JAM CAPABILITY. THE MOTOR DRIVE SYSTEM WILL CONTINUE TO MOVE UNTIL A LIMIT SWITCH IS CONTACTED. KEEP HANDS AND ANY OBJECTS CLEAR OF MECHANISM DURING OPERATION TO REDUCE RISK OF DAMAGE OR INJURY. Fully Closed Position WARNING: DO NOT OPERATE THE MECHANISM WITH THE WALL PLATE PARALLEL TO THE FLOOR THIS WILL CAUSE DAMAGE AND POSSIBLE FAILURE OF MECHANISM. 6
Page 9
CALCULATING MOUNTING HEIGHT 1 • Carefully offer the PSE90 mechanisms uprights to the back of the screen, lining up the screens VESA holes with the corresponding slots on the PSE90 Screen Mount Plate. X 2 • Measure from the top of the screen, down to the top mounting holes on the Wall plate (dimension X as indicated above) to determine positioning of the top wall fixing holes. Thecentreofthescreen'sVESA pattern should sit on this centre line 7
Page 10
OPENING THE BRACKET ClosedPosition 45° Position 1 • Hold the PSE90 by the wall plate, upside down (link arm underneath as shown) on a soft, non-abrasive surface that is free from any obstructions. 2 • Make sure the power is connected and press the HOME button on the remote control. This will open the PSE90 to the 45 degree position. 3 • Once the bracket has stopped moving, remove the power and turn the PSE90 the correct way up. 8
Page 11
WALL MOUNTING 1 2 • The top fixing holes for the PSE90 Wall • Fix the top two fixings to the wall, 200mm Plate should be located the distance of apart and symmetrically about the center Dimension X (previously measured) down line of the wall plate. from the top of the desired screen position. 3 4 • Check that the top two fixings are level, then • Drill and screw the remaining six fixings hang the mechanism onto the two fixings using in place using the holes in the Wall Mount the keyhole slots on the Wall Mount Plate. Plate as a template. Wall MountPlate NOTE: THE WALL FIXING HEADS SHOULD NOT PROTRUDE MORE THAN 5.5MM FROM THE WALL MOUNT PLATE NOTE: IT IS THE INSTALLERS RESPONSIBILITY TO CHOOSE THE Maximum Allowable Head APPROPRIATE FIXINGS WHEN Height of Fixings is ATTACHING TO THE WALL AND TO 5.5mm ENSURE THE MECHANISM IS SECURE AND SAFE BEFORE OPERATING. 9
Page 12
CABLE ROUTING 1 2 • Once fitted to the wall, the PSE90 rear arm • Once in the OUT position, remove the mains covers can be removed to allow easy cable power and remove the 4 x M4 bolts that routing. This is best done in the 90 degree secure the rear arm cover to the PSE90. OUT position. To open the bracket, plug in the mains power and press the OUT button on the IR Remote (Refer to page 14 for Operating Instructions.) 3 4 • Route TV power and signal cables through the • Replace the rear arm cover by re-securing mechanism as directed below. Ensure that the 4 x M4 bolts removed in step 2. enough clack is left for the movement of the mechanisms to avoid putting stress on the cables. All cables should also be well secured and kept as low profile as possible. 10
Page 13
SCREEN MOUNTING 1 • Secure the screen to the Screen Mount Plate using the bolts and washers provided in the Fixing Pack as shown below. If the Screen has recessed mount holes, or if you need to space the screen off for clearance, use the spacers provided in the Fixings Pack. This is best done in the 90 degree out position. To open the bracket, plug in the mains power and press the OUT button on the IR Remote (Refer to Page 14 for Operating Instructions.) 11
Page 14
FINAL CHECKS 1 • Make sure that both rear arm covers are fully secured to the mechanism. 2 • Check that there are no obstructions in the mechanisms movement (e.g. Cables caught between the Screen Mount Plate and Rear Arm.) 3 • Check that the mechanism is square and level on the wall. 12
Page 15
MECHANISM 1 PRESETS • The PSE90 has standard IN and OUT positions, as well as 7 programmable preset positions linked to the buttons shown below. 2 • To overwrite any of the preset positions, use the IN, OUT and STOP buttons to take the mechanisms to the desired position. Then press the STORE button, followed by the desired preset button (HOME, PRESET or A-F). These buttons will need to be pressed within two seconds of each other. NOTE: THE PRESET POSITIONS WILL NOT BE ACTIVE UNTIL THE MECHANISM HAS OPENED TO ITS FULLY OUT POSITION AND THEN CLOSED TO THE FULLY IN POSITION. NOTE: IF THE MECHANISM IS MOVING AND THE POSER IS CUT, TO REVISE ALL POSITIONS THE MECHANISMS NEEDS TO GO BACK TO THE IN POSITION, AFTER WHICH THE PREVIOUSLY STORED PROGRAMMED POSITIONS WILL BE RETAINED. 13
Page 16
INFRARED (IR) This Mechanism can be controlled via the supplied 14 button Infrared (IR) Remote Control, pair with the supplied Infrared (IR) lead and sensor. The mechanism's functions can be controlled by plugging the Infrared (IR) lead and sensor into the 3.5mm IR Input Jack shown on the General Mechanism Control page. Confirmation of Infrared (IR) input will be shown by a single flash of the large green LED located on the end of the control box. As Infrared (IR) control works over line of site, the Infrared (IR) sensor must be directly viewable from what ever location the remote control is being used from. Infrared (IR) Remote Control Button Layout IN - Brings the mechanism into STORE + PRESET - Pressed with the cabinet. 1 second of each other stores PRESET position. OUT - Brings the mechanism out of the cabinet, without STORE + A-F - Pressed with 1 swivelling. second of each other stores positions A-C. STOP - Will stop the operation of the mechanism at ANY position. STORE + OUT - Pressed with 1 second of each other stores OUT position. HOME (When paired with other Future Automation Product) - Takes panel/s open and PSE90 STORE + STOP + OUT - Pressed retracted against wall. with 1 second of each other clears learnt OUT position. A-F - Brings the mechanism to learnt position. PRESET - Brings the mechanism to learnt position. IMPORTANT Only buttons indicated above are functional with the product. Any other button press will STOP the mechanism. 14
Page 17
CONTACT CLOSURE This Mechanism can be controlled via Contact Closure, utilising the 8 Pin RJ45 Connector attached to a length of CAT5 (Type 568A or 568B) cable. The mechanism’s functions can be controlled by plugging this into the RJ45 port on the mechanism control board, then shorting pins 1-8 on this connector as shown in the Contact Closure Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box, as well as illumination of the corresponding Contact Closure LED on the printed circuit board as shown below. RJ45 Pin Layout Contact Closure LED Layout LED 1 LED 2 LED 3 LED 4 LED 5 (NOT USED) Contact Closure Input Port Contact Closure Input Table WIRE/CABLE TYPE PIN DESCRIPTION ACTION 568A 568B 1 12V SUPPLY 12V SUPPLY - CURRENT LIMITED W W GR O 2 12V LATCH WHEN 12V ATTACHED, DEVICE WILL GO OUT TO PRESET GR O POSITION. WHEN 12V REMOVED, DEVICE WILL GO IN. 3 GROUND GROUND W O WGR 4 DEVICE LATCH SHORT TO GROUND (PIN 3), DEVICE WILL GO OUT TO PRESET B B POSITION, REMOVE SHORT DEVICE WILL GO IN. 5 DEVICE HOME (ONLY IF PAIRED WITH PIC-LIFT MECHANISM) MOMENTARY SHORT TO W W GROUND (PIN3), MAKES DEVICE GO TO HOME. B B 6 DEVICE STOP MOMENTARY SHORT TO GROUND (PIN 3), STOPS DEVICE IN O GR CURRENT POSITION. 7 DEVICE OUT MOMENTARY SHORT TO GROUND (PIN 3), MAKES DEVICE GO W W OUT. BR BR 8 DEVICE IN MOMENTARY SHORT TO GROUND (PIN 3), MAKES DEVICE GO IN. BR BR 15
Page 18
RS232 CONTROL This Mechanism can be controlled via RS232, utilising a 6 Pin RJ11/RJ25 connector OR 9 Pin Serial connector attached to a length of 6 core cable. The mechanism's functions can be controlled by plugging this into the RJ11/RJ25 port on the mechanism control box, then inputting the RS232 commands shown in the RS232 Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box. RJ11/RJ25 PIN LAYOUT SERIAL PIN LAYOUT PIN 1: TX PIN 2: RX PIN 6: RX PIN 3: TX PIN 3 & 4: GROUND PIN 5: GROUND RS232 PROGRAMMING DETAILS RJ11/RJ25RJ11/RJ25 Func.Func. 9 PIN Serial9 PIN Serial ColourColour Baud Rate: 9600 PIN 1PIN 1 TX-RXTX-RX PIN 2PIN 2 Blue Stop Bit: 1 PIN 3PIN 3 GROUNDGROUND PIN 5PIN 5 Green Parity: None PIN 4PIN 4 GROUNDGROUND PIN 5PIN 5 Red Databits: 8 PIN 6PIN 6 RX-TXRX-TX PIN 3PIN 3 WhiteWhite RS232 INPUT TABLE IMPORTANT - Ensure all protocols are entered exactly as written below, including Carriage Return (ENTER / ASCII 13) 16
Page 19
NOTES
Page 21
EUROPEAN OFFICE NORTH AMERICAN OFFICE Address: Address: Unit 6-8 Enterprise Park Brunel Road 127 Venture Drive Bedford Dover Bedfordshire NH MK41 9TG 03820 Phone: +44 (0) 1438 833577 Phone: +1 (603) 742 9181 Email: info@futureautomation.co.uk Email: info@futureautomation.net OfÏce Hours: OfÏce Hours: Mon - Fri 8:00 to 17:30 GMT Mon - Fri 7:00 to 17:00 EST Saturday & Sunday - Closed Saturday & Sunday - Closed www.FUTUREAUTOMATION.net