This document could not be shown here. Open the PDF.
Text of this document7 pages · 1,407 words
Page 1
ISSUE 004 SHEET 1 of 7 Technical Sheet
PLF - Plasma Floor Lift FUNCTION DESIGN HIGHLIGHTS An electric lift to reveal a • Quiet smooth action with variable television from a floor. A speed motion separate electric walk on flap is included. • Full cable management • Stylish look and finish SUITABILITY • Wide range of mounting options This product can be custom made to suit any screen from 32" to 85". OPTIONS Maximum Load is 120Kg [265lb] • Marine suitable option • Swivelling version with 180 degree swivel to SPECIFYING the left and right. Swivelling version has three learnable preset positions. A fully waterproof floor recess is required to install • B and O and Loewe Mount Options. the mechanism. Various floor finishes can be • Telescopic versions for restricted floor accommodated. depths. CONTROL Supplied with basic infrared remote. Can be learnt by many learning remotes. Also has switch control and RS232 so can be operated by relays, switches, Crestron / AMX or Lutron systems. WARNING IMPORTANT It is the responsibility of Mechanisms which lift the installer to warn all or move weights need potential end users of to be checked on a the dangers of interfering yearly basis for any with mechanisms during damage which may operation result in an accident www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 2
ISSUE 004 SHEET 2 of 7 Technical Sheet
PLF - Plasma Floor Lift The mechanism is supplied as two parts. An electric flap mechanism and the main lift mechanism. Use the chosen screen size to determine the mechanisms required. PLAN SCREEN WIDTH For example: A Screen of 1650mm[65.0"] width and 960mm[37.8"] height would fit in a lift with reference PLF H1910 W1920. A custom height pole can be used by changing the overall lift height. The swivelling version (PLFS) has the same dimensions. Other widths and heights available. F F Maximum Screen Thickness - 160mm [6.3"] SCREEN HEIGHT Maximum Floor POLE Mechanism Height Screen Recess Pole Height HEIGHT Height Height H2010 1060[41.7] 2010[79.1] 500[16.7] H1910 960[37.8] 1910[75.2] 500[16.7] H1810 860[33.8] 1810[71.3] 500[16.7] BASE/FLAP UP WIDTH Maximum Floor Base/Flap MechanismWidth Screen Recess Width Width Width W1520 1250[49.2] 1520[59.8] 1270[50.0] W1620 1350[53.1] 1620[63.8] 1370[53.9] Stainless Steel Pole for swivel W1720 1450[57.1] 1720[67.7] 1470[67.9] and non swivel W1820 1550[61.0] 1820[71.7] 1570[61.8] versions. W1920 1650[65.0] 1920[75.6] 1670[65.7] W2020 1750[68.9] 2020[79.5] 1770[69.7] Base FLOOR DOWN Flap can be RECESS Removable floor insert walked on. HEIGHT to get access to mechanism. Electric flap mechanism retracts flap into the floor before lifting the screen. SECTION F-F The lift and the electric FLOOR RECESS WIDTH flap mechanism mount to the front face of the floor recess. Lift mechanism. Base fills the opening in the floor when in the up position. www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 3
ISSUE 004 SHEET 3 of 7 Technical Sheet
PLF - Plasma Floor Lift A PLAN Recess for Floor Insert INSERT RECESS WIDTH= 27.6 FLOOR RECESS WIDTH+150mm[5.9"] 700 7.8 7.7 198 196 B 439 30 to 36 B 17.3 6.2 158 0 [1.2 to 1.4] 14.8 Flap to fill the opening 7.1 A when the lift is down 376 181 Floor Insert 3.0 75 Floor 3.0 Insert 75 22.2 31.5 3 563 800 1 - Base to fill opening 2 when in the up position. 6 5 4 2 - Mechanism is fixed to this front face at the top and bottom. 3 - Electric flap mechanism 7 is fixed to this front face here on both sides. Viewing Side 7 4 - Power Supply Unit needs SECTION B-B 110/240V AC Supply SECTION A-A SCALE 1 : 12 SCALE 1 : 12 5 - Control Unit needs 110/240V AC Supply FLOOR RECESS HEIGHT 6 - Flap Unit needs 110/240V AC Supply 3.4 BASE WIDTH 86 7 - Cable Entry points 1 Clearance as 2 base moves 4.9 125 11.8 300 Clearance as base moves 21.7 22.0 550 560 FLOOR RECESS WIDTH www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 4
ISSUE 004 SHEET 4 of 7 Technical Sheet
PLF - Plasma Floor Lift FLOOR INSERT Viewing Side 27.5 0 698 21.3 6.2 The Floor Insert drops into 541 157 a recess created in the finished 7.8 7.8 floor surface. 197 197 10.2 17.2 260 438 27.5 0 30 to 36 698 [1.2 to 1.4] OPENING WIDTH OPENING WIDTH = BASE/FLAP WIDTH + 6mm [0.25] The Base and the Flap will fill the opening in the floor insert with a FLAP gap of 3mm [1/8"] around the edge. BASE/FLAP WIDTH 10.8 275 The Floor Insert, Base and Flap all need to be made from the finished floor material. This can be timber, stone or carpet (over timber). 0 30 to 36 The maximum weight of the Base or Flap must [1.2 to 1.4] BASE be no more than 25Kg [55lb]. BASE/FLAP WIDTH Stone or tiles can be used. To simplify the installation attach to an 18mm [0.75] piece of plywood. Up to 18mm of stone attached to 18mm of plywood will 10.8 give the maximum thickness of 36mm [1.5]. 275 5.8 3.5 147 90 0 30 to 36 [1.2 to 1.4] Viewing Side www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 5
ISSUE 004 SHEET 5 of 7 Fitting Notes
PLF - Plasma Floor Lift 30mm to 36mm recess for insert 0.5 GENERAL FITTING NOTES [1.2 to 1.4] 12 Power Supply Unit needs Possible control box location 110/240V AC Supply Fix the lift PLAN here 5.9 151 Position the flap mounting plates here on each side. Use bolt A A heads no greater than 7mm tall. Use sufficient fittings so that the weight of the mechanism is supported along with the possible weight of people 3.1 walking on top. Adjust dimensions 79 if the hole is wider than the specified width. • The lift can be checked and operated prior to insertion in the floor. Lay the main lift on its back and place the flap 3.1 mechanism alongside. Connect the 79 control system and test. Prior to The flap can then be dropped insertion in the hole, grease the main into place using the key hole rack. slots engaging on the flap mounting plates. • Fit the lift in the centre of the hole. • If the hole is too deep then place blocks underneath to keep the top of the lift at 12mm [0.5] from the top. •Fix on the flap mounting plates at the position shown. Change dimensions if the hole is wider than the width shown. Fix the lift here SECTION A-A SCALE 1 : 11 www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 6
ISSUE 004 SHEET 6 of 7 Fitting Notes
PLF - Plasma Floor Lift GENERAL FITTING NOTES UP SWITCH ADJUST This stop controls when the lift stops at the top. Adjust with Caution! Make sure the motor is stopping. Observe lights in control box so there is confidence that the motor Fix Flap to the Flap Mechanism has stopped. with screws from underneath. Use the Insert to assist when positioning With the beam at the top the Base can be fitted. Use the Insert to assist when positioning Slots enable Left to Right movement. FLAP ADJUST Remove uprights and fix to the screen. Then hook screen in place. Do not mount to high - clearance is needed as the flap l lifts and closes. Bolt enables Up and Down adjust. End plate enables Rock Run cables through cable track and and Front to Back adjust. then up through the pole. WARNING Always cover the STOP button on the remote when moving the mechanisms after fitting new parts. www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 7
ISSUE 004 SHEET 7 of 7 Cable Routing
PLF - Plasma Floor Lift Cable Routing Cables from the screen can be routed down through the Screen Mount and Pole and into the Beam. Cables must be routed carefully to prevent any interference with the beam as it operates. Mechanism cables should be routed to a control box ideally positioned at the top right of the cabinet, alternatively thr control box can be stored externally. H 16.7 425 5.9 150 10.1 257 16.8 16.5 428 420 SCREEN CABLE MECHANISM CABLE POWER CABLE SECTION G-G www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565 G G
Need assistance or looking to source this item?