This document could not be shown here. Open the PDF.
Text of this document12 pages · 2,122 words
Page 1
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 1 FUTUREAUTOMATION
Page 2
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY ADDITIONAL MOTOR OPTIONS: MODEL DESCRIPTION MIN SCREEN HEIGHT MAX SCREEN HEIGHT LSH-5-MO Z - SERVO MOTOR Vertical Lift for 55" Screens 680 [26 3/4"] 800 [31 1/2"] Higher lifting capacity & faster operation. See LSHZ-MO Tech 920 [36 1/4"] LSH-6-MO Vertical Lift for 65" Screens 800 [31 1/2"] 920 [36 1/4"] LSH-7-MO Vertical Lift for 75" Screens 1040 [40 15/16"] ADDITIONAL FLAP OPTIONS: LSH-8-MO Vertical Lift for 85" Screens 1040 [40 15/16"] 1160 [45 11/16"] LSHZ-9-MO Vertical Lift for 98" Screens 1160 [45 11/16"] 1280 [50 3/8"] 10-MO LSHZ- Vertical Lift for 105" Screens 1280 [50 3/8"] 1400 [55 1/8"] 1520 [59 13/16"] 11-MO Vertical Lift for 115" Screens 1400 [55 1/8"] LSHZ- 1520 [59 13/16"] 12-MO LSHZ- Vertical Lift for 120" Screens 1640 [64 9/16"] DSP - DROP & SLIDE HF - HINGING FLAP See LSH-DSP-MO Tech See LSH-HF-MO Tech ADDITIONAL MOVEMENT OPTIONS: I - INVERTED EP - EXTENSION POLE S - SWIVEL See I-LSH-MO Tech See LSH-EP-MO Tech See LSH-S-MO Tech (Upon request) TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 2 FUTUREAUTOMATION
Page 3
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY SPECIFICATION MEASUREMENTS Maximum Screen Height 1160mm [45 11/16"] Minimum Screen Height 1040mm [40 15/16"] Maximum Lifting Capacity 100Kg [220lbs] (Higher Lifting Capacity Option Available, see LSHZ-8-MO) Internal Cabinet Height 1410mm [55 1/2"] Packaging Dimensions TBC Shipping Weight TBC Movement Type Motorised Speed TBC Power Supply Required 110V - 240V AC Power Consumption 250 - 500W Power Consumption Standby 3W Mounting Patterns Supported VESA 600, 400, 300 W x 600, 400, 300 H Vertical Mounting Patterns Positioning Mount holes in the bottom 100mm [3 15/16"] of the screen require a VOA Adaptor Control Options IR Remote, RS232, Contact Closure, RF Available Colour Options Custom RAL paint finishes Package Contents Mechanism, IR remote control Marine Suitable Yes Outdoor Suitable Yes TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 3 FUTUREAUTOMATION
Page 4
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY GENERAL DIMENSIONS Note: For screens that are larger than 100mm [3 15/16"] the depths of the enclosure, base and top panel must be increased. 3 15/16" max. 3/16" 3/16" Screen Height + 20 [13/16"] 100 max. 5 5 A Screen Depth Screen Height Max. 1160 [45 11/16"] 55 1/2" Removable cabinet front Min. 1040 [40 15/16"] 1410 for access for installation Internal and servicing. Enclosure Height Screen Width 9 7/16" 240 12 1/16" 306 14 3/16" Mechanism 360 Depth A Min. Internal SECTION A-A Solid surface to Internal Enclosure Width = MECH UP Enclosure Depth mount lift to. Screen Width + 100 [4"] SECTION A-A MECH DOWN TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 4 FUTUREAUTOMATION
Page 5
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY APERTURE DETAILS 55 167 13/16" 0 6 9/16" 2 3/16" 0" + 55 [2 3/16"] 20 Top Panel Aperture Depth B Top Panel Height 13/16" 20 1 3/16" 30 (Suggested) Cabinet SCREEN Top Panel Cabinet Top Thickness Aperture Depth = Screen Depth + 135 [5 5/16"] (Minimum 235 [9 1/4"]) Recommended channel and rubber seals to prevent water ingress. Suitable drainage also recommended. DETAIL B Fixed Panel: Aperture Width = Screen Width + 60 [2 3/8"] (Box Enclosure: Aperture Width = Screen Width + 70 [2 3/4"]) A suggested top panel and floor surface construction based upon the dimensions shown on sheet 6. SCREEN VIEWING SIDE TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 5 FUTUREAUTOMATION
Page 6
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY BASE PANEL AND TOP PANEL DETAILS Base thickness to be equal to or larger than the cabinet thickness. BASE PANEL 1 3/16" Base Width = Aperture Width - 10 [3/8"] 30 C L C 0" 0 13/16" 20 Base Depth = Aperture Depth - 10 [3/8"] (Minimum 225 [8 7/8"]) 6 7/8" 175 C SECTION C-C VIEWING SIDE 0 0" 13/16" 130 130 20 5 1/8" 5 1/8" Suggested tapered detail. 3/16" 5 (Suggested) DETAIL E TOP PANEL 3/16" 5 Top Panel Width = Aperture Width + 40 [1 9/16"] C L D E 0" 0 2 3/16" Top Panel Depth = 55 Aperture Depth + 40 [1 9/16"] (Minimum 275 [10 13/16"]) 8 1/16" 205 D SECTION D-D VIEWING SIDE NOTE: Changes to the top panel will affect 0 0" the suggested dimension shown on sheet 5. 540 540 360 360 21 1/4" 21 1/4" 14 3/16" Recesses for top panel 14 3/16" TECHNICAL SHEET mount brackets. UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 6 FUTUREAUTOMATION
Page 7
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY General Mitigations: FIXED PANEL - INTEGRATION CONSIDERATIONS • Activate hold-to-run/dead-man switch operation. • Locate controls within direct line of sight of the mechanism. • Implement password or key switch protected operation. High Risk - Crushing Hazard Top Panel Crush hazard between the top panel and the cabinet top when the mechanism is closing. Mitigation The top panel is constructed to allow vertical movement in the presence of an obstruction, causing the mechanism to return to open again. Low Risk - Falling Objects Hazard Falling object hazard if objects are left on top of the top panel. High Risk - Crushing Hazard Crush hazard at the cabinet aperture when Mitigation mechanism is opening. See general mitigations. Cabinet Top Mitigation A Tapeswitch can be installed underneath the base panel to detect any obstructions. Scan the QR code and navigate to the Cabinet Guidelines document for further details. Base Panel Low Risk - Crushing Hazard Cables could be snagged if not properly managed High Risk - Crushing Hazard through and around the mechanism, causing Crush hazard below the mechanism when the damage to the mechanism and electronics. mechanism is closing. Mitigation Mitigation Ensure sufficient cable slack is allowed around Ensure the area below the mechanism is kept movement joints to prevent stretching and/or clear at all times when the mechanism is being damage to the cables and/or mechanism. used. If installing or maintaining the mechanism do so with the mechanism turned off. The installer is responsible for conducting a site-specific risk assessment. Due to the unique conditions of each installation, Future Automation cannot provide an exhaustive list of all potential risks. Installers must ensure that all risks associated with installation, operation, and maintenance are identified and mitigated in accordance CONSIDERATIONS SHEET with applicable legislation and best practice. UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 Further safety and servicing guidance is available at: www.futureautomation.net/safety WWW NET . . SHEET 7 FUTUREAUTOMATION
Page 8
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY Top Safety Panel BOX ENCLOSURE DETAILS For size specific box enclosures with further details, please see CAD. Maximum lifting capacity: 100kg [225lbs] Z - SERVO MOTOR Higher lifting capacity & faster operation. See LSHZ-MO Tech Box Enclosure Base 13/16" 20 Side Panel Thickness F Removable panel to allow access to mount adjustment from the rear Internal Box Enclosure Depth = Screen Depth + 95 [3 3/4"] 23 5/8" 740 (Minimum 195 [7 11/16"]) Box Enclosure Height = 600 29 1/8" Removable Panel Screen Height + 20 [13/16"] Width Internal Box Enclosure Height = Screen + Base Panel Height + 20 [13/16"] Removable Panel Height Base Depth = SECTION F-F Screen Depth + 115 [4 1/2"] 1" (Minimum 215 [8 7/16"]) F 25 Internal Box Enclosure Width = Screen Width + 10 [3/8"] TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 8 FUTUREAUTOMATION
Page 9
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY BOX ENCLOSURE - BOX ENCLOSURE BASE AND TOP SAFETY PANEL DETAILS TOP PANEL For top panel dimensions, please see sheet 6. Base thickness to be equal to or larger than the cabinet thickness. BOX ENCLOSURE BASE 1 3/16" Base Width = Screen Width + 10 [3/8"] 30 C L G 0" 0 Base Depth = 13/16" Screen Depth + 115 [4 1/2"] 20 (Minimum 215 [8 7/16"]) 6 11/16" 170 G SECTION G-G VIEWING SIDE 0 0" 130 130 TOP SAFETY PANEL 5 1/8" 5 1/8" 3 3/8" max. 13/16" Top Safety Panel Width = Screen Width + 10 [3/8"] 20 85 max. C L 4x 12 1/2" THRU 0" 0 3/8" 10 2 1/8" VIEWING SIDE 53.5 0 0" 520 400 400 520 500 380 380 500 20 1/2" 15 3/4" 15 3/4" 20 1/2" 19 11/16"14 15/16" 14 15/16"19 11/16" TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 9 FUTUREAUTOMATION
Page 10
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY General Mitigations: BOX ENCLOSURE - INTEGRATION CONSIDERATIONS • Activate hold-to-run/dead-man switch operation. • Locate controls within direct line of sight of the mechanism. • Implement password or key switch protected operation. High Risk - Crushing Hazard Top Panel Crush hazard between the top panel and the cabinet top as the lift closes. Mitigation The top panel is constructed to allow vertical movement in the presence of an obstruction, causing the mechanism to return to open again. Low Risk - Falling Objects Hazard Box Enclosure Falling object hazard if objects are left on top of the top panel. Mitigation Low Risk - Crushing Hazard See general mitigations. Crush hazard at the cabinet aperture when mechanism is opening. Cabinet Top Mitigation A Tapeswitch can be installed underneath the base panel to detect any obstructions. Scan the QR code and navigate to the Cabinet Safety document for further details. Base Panel Low Risk - Crushing Hazard Cables could be snagged if not properly managed High Risk - Crushing Hazard through and around the mechanism, causing Crush hazard below the mechanism when the damage to the mechanism and electronics. mechanism is closing. Mitigation Mitigation Ensure sufficient cable slack is allowed around Ensure area below the mechanism is kept clear movement joints to prevent stretching and/or at all times when the mechanism is being used. damage to the cables and/or mechanism. If installing or maintaining the mechanism do so with the mechanism turned off. The installer is responsible for conducting a site-specific risk assessment. Due to the unique conditions of each installation, Future Automation cannot provide an exhaustive list of all potential risks. Installers must ensure that all risks associated with installation, operation, and maintenance are identified and mitigated in accordance CONSIDERATIONS SHEET with applicable legislation and best practice. UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 Further safety and servicing guidance is available at: www.futureautomation.net/safety WWW NET . . SHEET 10 FUTUREAUTOMATION
Page 11
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY CABLE ROUTING Screen cables should be routed through the cable management chain, over the top of the beam and through the centre of the screen mount. Mechanism cables should be routed to the control box, which should be stored in a safe and accessible location. MECHANISM CABLES MAINS POWER SCREEN CABLES To external connections Control Box To mains power (110V or 240V AC) Power Supply Unit TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 11 FUTUREAUTOMATION
Page 12
LSH-8-MO MARINE OUTDOOR LIFT SYSTEM HEAVY CONTROL BOX DETAILS 9 13/16" 5 1/16" 12 3/8" 250 128 315 FUTURE AUTOMATION UDC3 CONTROL BOARD 170 1/16" 252 9 7/8" 6 11/16" R2.3 POWER SUPPLY UNIT INPUT = 110V (6A) OR (240V) AC MAINS OUTPUT = 24V DC, 21A CABLE LOOM LENGTH APPROX. 118 1/8" 3000 3 CORE CABLE IR RECEIVER 3mm [0.12"] dia. EU SPEC: 0.12mm² US SPEC: 25AWG 3 CORE CABLE MAINS SUPPLY 6mm [0.25"] dia. EU SPEC: 0.75mm² US SPEC: 18AWG 3 CORE CABLE LIFTING BEAM SWITCH LIMITS 6mm [0.25"] dia. EU SPEC: 0.5mm² US SPEC: 20AWG NOTES 2 CORE CABLE • ENCLOSURE AND CABLE GLANDS RATED TO IP56. LIFTING BEAM MOTOR • ENCLOSURE AND LID FIXINGS ALL MADE FROM GEWISS GW PLAST 75. 10mm [0.4"] dia. • C TO -25 C. ENCLOSURE MATERIAL SUITABLE FOR TEMPERATURES +60 EU SPEC: 1.5mm² US SPEC: 16AWG • POWER SUPPLY UNIT (PSU) WILL ALLOW 110V OR 240V AC INPUT. THE SAME PSU IS USED FOR EU OR US MAINS SUPPLIES. • OTHER THAN CONTROL CABLES, ALL CABLES TERMINATE AT CONTROL BOARD VIA STANDARD PHOENIX CONNECTORS. • CABLE LOOM LENGTH SUPPLIED AT APPROX. 3m [118"]. LOOM CAN BE EXTENDED UP TO MAXIMUM OF APPROX. 10m [400"]. • MINIMUM CABLE BEND RADIUS 25mm [1"]. TECHNICAL SHEET UK +44 (0) 1438 833577 US +1 (603) 742 9181 ISSUE 001 WWW NET . . SHEET 12 FUTUREAUTOMATION
Need assistance or looking to source this item?