ISSUE 001 SHEET 1 of 7 Installation Guide FME - Floor Mount Electric WARNING IMPORTANT It is the responsibility of Mechanisms which lift the installer to warn all or move weights need potential end users of to be checked on a the dangers of interfering yearly basis for any with mechanisms during damage which may operation result in an accident www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 2
ISSUE 001 SHEET 2 of 7 Installation Guide FME - Floor Mount Electric Package Contents SCREEN MOUNT COVER Each FME will be shipped in two sub- assemblies; mount and base, along with all necessary fixings and cables. Before installing the mechanism ensure that the instructions are read carefully and that all parts and wiring are undamaged and secure. SCREEN MOUNT PLATE MOUNT SUB-ASSEMBLY CENTRE TUBE BOTTOM COVER FLANGE BASE TOP IR RECEIVER TRANSPORT BRACKET BASE PLATE BASE SUB-ASSEMBLY UPPER PLATE www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 3
ISSUE 001 SHEET 3 of 7 Installation Guide FME - Floor Mount Electric INCORRECT INSTALLATION CORRECT INSTALLATION Mechanism Positioning LEFT LEFT The FME enables a screen to be rotated Limit Switch Limit Switch up to 60 in both directions from center. Software allows intermediate positions to be learnt and selected using the IR remote. ! IMPORTANT ! RIGHT In installations where the full 120 of Limit Switch travel is not required or possible it is RIGHT important that the RIGHT end switche can Limit Switch be seen to ensure accurate and consistent positioning of the mechanism. 90° 90° If there are obstructions that prevent the mechanism being able to rotate 120 the RIGHT limit switch must be positioned Install Sweep Install Sweep within the installation sweep angle. 120° 120° Max Sweep A new LEFT limit position can be set using the IR remote (see Page 4). Max Sweep The installation sweep angle works within the The installation sweep angle shares an end point Arrow cut-outs in the base plate show maximum sweep angle so neither limit switch can with the maximum sweep angle, allowing the each limit switch position, these should be be seen during normal operation. RIGHT limit switch to be seen. used when positioning the mechanism. Cut-outs in base plate identify limit switch positions www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 4
ISSUE 001 SHEET 4 of 7 Installation Guide FME - Floor Mount Electric Mechanism Control LEFT RIGHT A F B E C D PRESET MECHANISM RESET SETTING LEFT LIMIT PRESET POSITIONS If the mechanism does not see one of the limit If the full 120 travel cannot be used because Preset positions become active once the switches for a long period of time its position of physical obstructions the LEFT limit can be mechanism has travelled fully LEFT and fully counting may lose accuracy. programmed by stopping the mechanism at RIGHT or a maximum LEFT limit is set. the desired position and pressing STORE then To re-reference the position counting simply LEFT. To adjust presets press STOP in the desired send the mechanism to the RIGHT position. position then STORE and you’ll have a 2 sec window to press PRESET or buttons A-F to This limit can be cleared by pressing STORE If the full 120 then STOP then LEFT. save that position to that particular button. sweep is not being used the mechanism must be able to be sent to the If the LEFT limit is set by the installer the If the power is cut while the mechanism is RIGHT limit (see Page 3 for details). preset positions will be equally spaced moving its position will need to be re- between this new travel sweep. referenced (see Mechanism Reset). Until referenced, the mechanism will not be able to access stored positions and will only be able to move right in short pulses. www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 5
ISSUE 001 SHEET 5 of 7 Installation Guide FME - Floor Mount Electric Installation 1. Remove Base Top from Base sub-assembly. 2. Remove 4 x M4 bolts from Center Tube and lift off screen mount. 3. Mount the Center Tube to the Base Top Plate using 4 x M6x12 bolts supplied. Note: The tube must be orientated so that the IR receiver is facing in the direction shown. 4. Remove the red Transport Bracket from the base. ! IMPORTANT ! This must be removed before operating the mechanism. www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 6
F ISSUE 001 SHEET 6 of 7 Installation Guide FME - Floor Mount Electric Installation 5. Run screen cables up Center Tube. Screen and power cables can terminate in the center of the mechanism or run out underneath to another location. F 6. SIDE ELEVATION Remove Cover from Screen Mount by releasing 4 x M6 CSK bolts. SCREEN MOUNT COVER 7. Fix screen to Screen Mount using appropriate fixings. Note: Spacers may be required if the screen SCREEN MOUNT PLATE mounting holes are recessed or if the back of the screen is not flat. SCREEN 8. Slide Base Top and Bottom Cover over Center Tube before remounting Screen Mount (screen not shown) www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565
Page 7
ISSUE 001 SHEET 7 of 7 Installation Guide FME - Floor Mount Electric Installation 9. Power mechanism to the RIGHT position and position the base so that all criteria mentioned on Page 3 are satisfied. 10. Return mechanism to its central position, rotate base top as shown and fix to the floor through 4 x 12mm fixing holes. 11. Make any adjustments to the vertical position of the TV and remount Back Cover. 12 0.5 TYP www.futureautomation.co.uk tel: +44 (0) 1438 833 577 fax: +44 (0) 1438 833 565