EAD100 ELECTRONIC ADVANCE AND DROP TV WALL MOUNT INSTALLATION INSTRUCTIONS ISSUE 001

Page 3

SAFETY DISCLAIMER IMPORTANT SAFETY INSTRUCTIONS BELOW WARNING: Failure to provide adequate structural strengthening, prior to installation can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure the structure to which the component is affixed can support four times the weight of the component and any additional apparatus mounted to the component. WARNING: Do not exceed the weight capacity for this product as listed below. This can result in serious personal injury or damage to the equipment. It is the installer’s responsibility to ensure that the total combined weight of all attached components does not exceed that of the maximum figure stated. WARNING: Risk of death or serious injury may occur when children climb on audio and/or video equipment or furniture. A remote control or toys placed on the furnishing may encourage a child to climb on the furnishing and as a result the furnishing may tip over on to the child. WARNING: Risk of death or serious injury may occur. Relocating audio and/or video equipment to furniture not specifically designed to support audio and/or video equipment may result in death or serious injury due to the furnishing collapsing or over turning onto a child or adult. WARNING – RISK OF INJURY! Only for use with equipment weighing 353LBS (160KG) OR LESS. Use with heavier screens/equipment may lead to instability causing tip over or failure resulting in death or serious injury. Bracket Suitable for Residential and Commercial Use. ADDITIONAL WARNINGS: 1. Keep all documentation/instructions after fitting. 2. Read all technical instructions fully before installation and use. It is the installer’s responsibility to ensure that all documentation is passed on to the end user and read fully before operation. 3. Do not use near water or outdoors unless the product has been specifically designed to do so. 4. Protect any cables or cords being used near this bracket from being walked on or pinched to prevent damage and risk of injury. 5. Use this product only for its intended purpose as described in the product instructions and only use attachments/ accessories specified by the manufacturer. 6. Do not operate the product if it is damaged in any way, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. Contact the original installer/manufacturer to arrange repair or return. WARNING - To reduce the risk of burns, fire, electric shock, or injury to persons: 1. Clean only with a dry cloth and always unplug any electrical items being used in conjunction with this product before cleaning. WARNING - The mechanism can be damaged when exposed to heat or naked flames: 1. Future Automation accept no responsibility for products damaged by exposure to heat or naked flames. 2. The mechanism can be damaged by extreme heat in any position, before, during and after installation. 3. It is up to the consumer to ensure proper precautions are taken to avoid damage to the mechanism, display, or accessories. 4. Future Automation recommend against having fires in a fireplace in the vicinity of electrical mechanisms. Future Sound & Vision trading as Future Automation intend to make this and all documentation as accurate as possible. However, Future Automation makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without prior notice or obligation of any kind. Future Automation makes no representation of warranty, expressed or implied, regarding the information contained herein. Future Automation assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document. 1

Page 4

PRODUCT WARRANTY & RISK ASSESSMENT WARRANTY INFORMATION WARNING - The warranty offered for this product shall be annulled if the product is used improperly or in a way that is in breach of our Terms of Service. Future Automation provides warranty for the mechanism you purchased for the period of 24 months from the date of purchase, provided that it isn’t used for unintended purposes. Under the warranty, Future Automation aims to either solve the issue remotely (via telephone or email support) or if the mechanism requires a part, arrange a visit to your premises by a Future Automation approved engineer or send replacement items where appropriate. Warranty repairs will be carried out as quickly as possible, but subject to parts availability. This warranty period is respectively extended for the period of a repair. A malfunctioning product must be cleaned and placed into suitable packaging to protect against transit damage before organising delivery to a repair workshop. All the complaints about defects must be submitted to the vendor/installer that sold this product, rather than directly to the manufacturer. Any part of your system that needs to be replaced during a warranty repair becomes the property of Future Automation. The warranty does not cover the following: • Damages resulting from improper product use or maintenance. • Repairs carried out by unauthorized persons. • Natural wear and tear during operation. • Damages caused by the buyer. • Accidental damages caused by a customer or damages caused as a result of careless attitude or usage, or damages caused by natural disasters (natural phenomena). • Any electrical, or other environmental work external to your Future Automation mechanism including power cuts, surges etc. • Additional items not supplied by Future Automation although they may have been supplied together by the retailer • Any 3rd party software products controlling your mechanism • Any transfer of ownership. Warranty is provided only to the initial purchaser. • Compensation for loss of use of the product, and consequential loss of any kind. A separate Safety and Servicing Information document is provided with these instructions (additional copies can be found at www.futureautomation.co.uk/safety), and this document MUST be filled out by the approved Future Automation Dealer who is installing the product. This Warranty Sheet must be held by the end user for the duration of the products life and will be referred to during servicing or warranty queries. The Safety and Servicing Information document also contains two Service History Forms that must be filled in by the approved Future Automation dealer who is performing the first required yearly service of this product. One copy of the Service History Form must be held by the customer (along with the Warranty Sheet) and a duplicate copy must be held by the approved Future Automation dealer that performed the service. Missing and/or mismatching documents may delay or invalidate warranty claims. Additional Service History Forms can be found on the Future Automation website for further yearly services. RISK ASSESSMENT INFORMATION It is the installer’s responsibility to perform a risk assessment of installed products. Future Automation can provide guidelines to installers/dealer about what should be included in a risk assessment, but due to the individual nuances of each location/site, Future Automation cannot provide a full list of areas to risk assess. For full risk assessment and safety information please view our Safety and Servicing guide available at www.futureautomation.net/safety 2

Page 5

GUIDE CONTENTS SAFETY DISCLAIMER 1 PRODUCT WARRANTY & RISK ASSESSMENT 2 GUIDE CONTENTS 3 PACKAGE CONTENTS 4 MECHANISM QUICK-START GUIDE 5 MECHANISM MOUNTING 6 CABLE MANAGEMENT 8 SCREEN MOUNTING 10 IN SWITCH ADJUSTMENT 12 GENERAL CONTROL 13 INFRARED (IR) 14 RADIO FREQUENCY (RF) 15 CONTACT CLOSURE 16 RS232 CONTROL 17 NOTES: 18 NOTES: 19 3

Page 6

PACKAGE CONTENTS 1 - EAD100 1.1 - INSTALLATION WALL PLATE 1.2 - EAD100 MECHANISM 1.3 - SCREEN MOUNT UPRIGHT (X2) 1.4 - MAGNETIC COVERS 1.5 - CABLE MANAGEMENT CLAMP (X3) 2 - Control Box (Size and Style May Vary) 3 - Infrared (IR) Remote Control ITEMS NOT SHOWN ON PAGE EAD ACCESSORY PACK - X2 AAA BATTERIES - MULTI-PACK OF NUTS, BOLTS AND WASHERS - MAINS POWER, IR AND CONTACT CLOSURE LEADS 1.3 1.2 1.3 3 1.1 1.4 2 4

Page 7

MECHANISM QUICK-START GUIDE Some Future Automation mechanisms may ship with the control box disconnected to prevent damage during transit. In order to operate the mechanism, the control box will need to reconnected, then have mains power applied along with the desired control method. RECONNECTING THE CONTROL BOX To reconnect the mechanism control box, follow the below steps: 1. Make sure the power is disconnected from the control box. 2. Remove the retaining screw and washer from the end of the control box to allow removal of the control box lid. (Image 1 Below). 3. Slide off the control box lid to reveal the control board inside. 4. Locate the green connector on the end of the loom leading from the lift mechanism. This plug will have a small tag attached stating the correct connecting socket on the control board (e.g. “AC1”, “DC2”...) (Image 2 Below). 5. Plug the green connector into the corresponding socket on the control board. This plug is handed and will only connect correctly one way. Do NOT force the connector into the socket, this can cause serious damage to the control board and mechanism. 6. Route the wiring loom out of the end of the control box by inserting the black plastic inserts into the slots provided. (Image 3 Below). 7. Slide the control box cover back over the control board and replace the fixing screw and washer. Image 1. Image 2. Image 3. Image 4. IMPORTANT For the mechanism to operate, the green three way safety connector with the loop of wire attached, must also be plugged into the end of the control box. (Image 4 above). If this connector is not plugged in, a bright red LED will be visible inside control board and the Input Confirmation Input LED will be permanently illuminated. 5

Page 8

MECHANISM MOUNTING It is the installers responsibility to ensure the mounting wall is structurally suitable and appropriate fixings are used before continuing installation. 1 Secure the Installation Wall Plate to the wall through the 6 x 6.6mm countersunk holes (fixings NOT provided). See EAD100 Technical Sheet for Wall Plate positioning guide. 2 Hook the EAD100 mechanism onto the Installation Wall Plate This is an intallation aid, DO NOT run the mechanism until ALL load bearing fixings have been secured. 6

Page 9

MECHANISM MOUNTING CONT. 3 Secure the mechanism to the wall through ALL 8 x Ø10.5mm holes (fixings NOT provided). DO NOT run the mechanism until ALL 8 load bearing fixings have been secured. 4 Fixings Per Side 4 Power up the mechanism using the Quick Start Guide on Page 5 and fully extend the mechanism by pressing the OUT button on the IR Remote Control to test function. Slide the Magnetic Covers onto the wall billets to hide fixings 7

Page 10

CABLE MANAGEMENT 1 Open the EAD100 by pressing the OUT button on the IR Remote Control to access the cable management areas. Unscrew the bolts holding the Cable Management Clamps in place and remove them from the mechanism. Cable Management Clamps Cable Keep these safe as they will be used again later Management to secure all cables in place. Clamp Cable Management Clamps 2 Run the screen cables into the lower arm at the rear of the mechanism. Secure the cables to the cable saddle at the base of the Installation Wall Plate. Ensure sufÏcient slack is left around the pivot point. Cable Saddle 8 Cable Management Clamps

Page 11

CABLE MANAGEMENT CONT. 3 Route the screen cables along the inside of the lower arm to the front of the mount & secure using the Cable Management Clamps. Ensure no cable diameters are larger than 10mm [0.4”]. NOTE: Stacking cables along the central arm will interfere with the mechanism during operation. 4 Secure the cables to the Front Cable Tie Bracket. Ensure sufÏcient slack is left around pivot points for both the Electric drop motion and Manual Swivel. 9

Page 12

SCREEN MOUNTING 1 Loosen the rear Hex Pinch Bolt at the top of the Screen Mount Upright & unhook the screen uprights. Hex Pinch Bolt 2 Lay the screen face down on a padded surface and offer up the Screen Mount Uprights. Secure the Uprights to the back of the screen using the fixing pack provided. 4.9 124 The bottom of the Mount Uprights will sit 124mm above the bottom of the wall plate when in the IN position 4.9 4.9 124 124 10 4.9 124

Page 13

SCREEN MOUNTING CONT. 3 Hook the Screen Uprights onto the EAD100, aligning the screen horizontally central with the mechanism. 4 Rotate BOTH Height Adjuster Screws to raise/ lower the screen. Rotate BOTH Tilt Adjuster Screws to make the screen parallel to the wall. Height Adjuster Screw Tilt Adjuster Screw Once all adjustments are made, re-secure the rear Hex Pinch Bolt on both uprights. 11

Page 14

IN SWITCH ADJUSTMENT Press OUT to open the mechanism until the Switch Adjustment Bolt on the TOP face of the central drive unit is revealed. Rotate CW to trim the IN position TOWARDS the wall. Rotate CCW to trim the IN position AWAY from the wall. DO NOT adjust the bolt on the side of the central drive unit Switch Adjustment Bolt DO NOT ADJUST 12

Page 15

GENERAL CONTROL This mechanism has multiple standard control methods, each of which requires a different input method to the control box. For ease, the input sockets on the control board are labelled below. (Control box size and style may vary to image shown) Mains Voltage Input CONTROL BOX INPUTS RS232 (RJ11/RJ25) Contact Closure (RJ45) Input Confirmation LED Emergency Stop Connector IR Input Jack (3.5mm) MECHANISM EMERGENCY STOP CONNECTOR This mechanism features an Emergency Stop Connector, which MUST be plugged into the control box in the connector labelled above for the mechanism to operate. If this connector is not plugged in, the Input Confirmation LED will be permanently lit. As per the red plastic tag attached to the Emergency Stop Connector (and shown below), the small loop of wire in this connector is designed to be replaced by a third party safety mechanism. REPLACING MECHANISM BATTERIES The standard Future Automation Infrared (IR) remote control requires x2 AAA batteries to operate. These are provided with the mechanism in the Accessories Pack. These batteries can be replaced as the per the image below. 13

Page 16

INFRARED (IR) This Mechanism can be controlled via the supplied 14 button Infrared (IR) Remote Control, pair with the supplied Infrared (IR) lead and sensor. The mechanism's functions can be controlled by plugging the Infrared (IR) lead and sensor into the 3.5mm IR Input Jack shown on the General Mechanism Control page. Confirmation of Infrared (IR) input will be shown by a single flash of the large green LED located on the end of the control box. As Infrared (IR) control works over line of site, the Infrared (IR) sensor must be directly viewable from what ever location the remote control is being used from. Infrared (IR) Remote Control Button Layout IN - Brings the mechanism into STORE + D-F - Pressed with 1 the cabinet. second of each other stores positions D-F. OUT - Brings the mechanism out of the cabinet, without STORE + OUT - Pressed with 1 swivelling. second of each other stores OUT position. STOP - Will stop the operation of the mechanism at ANY position. STORE + STOP + OUT - Pressed with 1 second of each other clears learnt OUT position. HOME (When paired with other Future Automation Product) - Takes panel/s open and EAD retracted against wall. D-F - Brings the mechanism to learnt position. IMPORTANT Only buttons indicated above are functional with the product. Any other button press will STOP the mechanism. 14

Page 17

RADIO FREQUENCY (RF) If purchased with the Radio Frequency (RF) control option, this mechanism can be controlled via the supplied 4 button Radio Frequency (RF) Remote Control, paired with the in-built Radio Frequency (RF) sensor. Confirmation of Radio Frequency (RF) input will be shown by a single flash of the large green LED located on the end of the control box. Radio Frequency (RF) control does not require line of site, but signal can affected cabinet thickness, cabinet material or other electronic signals (i.e. strong WIFI signals). Radio Frequency (RF) Remote Control Button Layout IN - Brings the mechanism into OUT - Brings the mechanism the cabinet. out of the cabinet, without swivelling. STOP - Will stop the operation of STOP - Will stop the operation of the mechanism at ANY position. the mechanism at ANY position. The Radio Frequency (RF) Remote Control can only be used to recall the above functions. The mechanism limits and preset positions must be programmed using the supplied Infrared (IR) Remote Control. IMPORTANT Pressing any button while the mechanism is moving will STOP the mechanism. 15

Page 18

CONTACT CLOSURE This Mechanism can be controlled via Contact Closure, utilising an 8 Pin RJ45 Connector attached to a length of CAT5 (Type 568A or 568B) cable. The mechanism’s functions can be controlled by plugging this into the RJ45 port on the mechanism control board, then shorting pins 1-8 on this connector as shown in the Contact Closure Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box, as well as illumination of the corresponding Contact Closure LED on the printed circuit board as shown below. RJ45 PIN LAYOUT CONTACT CLOSURE LED LAYOUT LED 1 LED 2 LED 3 LED 4 LED 5 (NOT USED) Contact Closure Input Port CONTACT CLOSURE INPUT TABLE WIRE/CABLE TYPE PIN DESCRIPTION ACTION LED 568A 568B INDICATOR 1 12V SUPPLY 12V SUPPLY - CURRENT LIMITED W W G O 2 12V LATCH WHEN 12V ATTACHED, DEVICE WILL MOVE TO D G O POSITION. WHEN 12V REMOVED, DEVICE WILL GO IN. 3 GROUND GROUND W O W G B B 5 DEVICE LATCH (PRE- SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO D W W LED 4 SET) POSITION, WHEN REMOVED DEVICE WILL MOVE TO IN POSITION. B B 6 DEVICE STOP MOMENTARY SHORT TO GROUND (PIN 3), STOPS DEVICE IN O G LED 3 CURRENT POSITION. 7 DEVICE OUT MOMENTARY SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO W W LED 2 OUT POSITION. BR BR 8 DEVICE IN MOMENTARY SHORT TO GROUND (PIN 3), DEVICE WILL MOVE TO IN BR BR LED 1 POSITION. IMPORTANT THE DEVICE CAN BE STOPPED BY SHORTING PINS 5,6,7 OR 8 TO GROUND (PIN 3) WHILST THE DEVICE IS MOVING 16

Page 19

RS232 CONTROL This Mechanism can be controlled via RS232, utilising a 6 Pin RJ11/RJ25 connector OR 9 Pin Serial connector attached to a length of 6 core cable. The mechanism's functions can be controlled by plugging this into the RJ11/RJ25 port on the mechanism control box, then inputting the RS232 commands shown in the RS232 Input Table below. Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on the end of the control box. RJ11/RJ25 PIN LAYOUT SERIAL PIN LAYOUT PIN 1: TX PIN 2: RX PIN 6: RX PIN 3: TX PIN 3 & 4: GROUND PIN 5: GROUND RS232 PROGRAMMING DETAILS RJ11/RJ25RJ11/RJ25 Func.Func. 9 PIN Serial9 PIN Serial ColourColour Baud Rate: 9600 PIN 1PIN 1 TXTX PIN 2PIN 2 Blue Stop Bit: 1 PIN 3PIN 3 GROUNDGROUND PIN 5PIN 5 Green Parity: None PIN 4PIN 4 GROUNDGROUND PIN 5PIN 5 Red Databits: 8 PIN 6PIN 6 RXRX PIN 3PIN 3 WhiteWhite RS232 INPUT TABLE IMPORTANT - Ensure all protocols are entered exactly as written below, including Carriage Return (ENTER / ASCII 13) Protocol Action fa_in Carriage Return (Enter / ASCII 13) Device IN fa_out Carriage Return (Enter / ASCII 13) Device OUT fa_stop Carriage Return (Enter / ASCII 13) Device STOP (At any position) 17

Page 20

NOTES:

Page 21

NOTES:

Page 22

EUROPEAN OFFICE NORTH AMERICAN OFFICE Address: Address: Unit 6-8 Enterprise Park Brunel Road 127 Venture Drive Bedford Dover Bedfordshire NH MK41 9TG 03820 Phone: +44 (0) 1438 833577 Phone: +1 (603) 742 9181 Email: info@futureautomation.co.uk Email: info@futureautomation.net OfÏce Hours: OfÏce Hours: Mon - Fri 8:00 to 17:30 GMT Mon - Fri 7:00 to 17:00 EST Saturday & Sunday - Closed Saturday & Sunday - Closed www.FUTUREAUTOMATION.net